摘要
A new Roentgen Stereophotogrammetric Analysis (RSA) system is reported; it can measure penetration of the metallic femoral component of a Total Knee Replacement (TKR) prosthesis into the polyethylene bearing on the tibial component. This system was used to analyse a study group of six Anatomic Graduated Components (AGC) knee prostheses more than 6 years post-implantation, and to compare with a control group of six newly implanted AGC prostheses. The volumetric loss of polyethylene was estimated by imaging each prosthesis at a series of different knee flexion angles. The mean difference between the RSA measured polyethylene bearing thickness and the manufacturer's quoted values for the control group was -0.03 mm (SD 0.17). The estimated linear penetration at 6.4 years in this prosthesis was determined to be 0.1 mm/year. Volumetric wear was estimated to be 600-700 mm(3)/year at 6.4 years, equating to similar to 100 mm(3)/year. This does not appear to be clinically significant amount of wear as this prosthesis has excellent survival at 10 years. (C) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:312 / 317
页数:6
相关论文
共 18 条
[1]   Technical feasibility and precision of radiostereometric analysis as an outcome measure in canine cemented total hip replacement [J].
Allen, MJ ;
Hartmann, SM ;
Sacks, JM ;
Calabrese, J ;
Brown, PR .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2004, 9 (01) :66-75
[2]   Particles and periimplant bone resorption [J].
Bauer, TW .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (405) :138-143
[3]  
BELL CJ, 1999, THESIS U LONDON, P216
[4]   Experimental assessment of precision and accuracy of radio stereometric analysis for the determination of polyethylene wear in a total hip replacement model [J].
Bragdon, CR ;
Malchau, H ;
Yuan, XH ;
Perinchief, R ;
Kärrholm, J ;
Börlin, N ;
Estok, DM ;
Harris, WH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2002, 20 (04) :688-695
[5]   Development of a six station knee wear simulator and preliminary wear results [J].
Burgess, IC ;
Kolar, M ;
Cunningham, JL ;
Unsworth, A .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (01) :37-47
[6]  
Deng M, 1998, J BIOMED MATER RES, V40, P214, DOI 10.1002/(SICI)1097-4636(199805)40:2<214::AID-JBM6>3.3.CO
[7]  
2-M
[8]   Degradation of mechanical behavior in UHMWPE after natural and accelerated aging [J].
Edidin, AA ;
Jewett, CW ;
Kalinowski, A ;
Kwarteng, K ;
Kurtz, SM .
BIOMATERIALS, 2000, 21 (14) :1451-1460
[9]  
Hall R M, 1996, Proc Inst Mech Eng H, V210, P197, DOI 10.1243/PIME_PROC_1996_210_413_02
[10]   A radiological technique for the assessment of wear in prosthetic knee replacements [J].
Hide, IG ;
Grainger, AJ ;
Wallace, IW ;
Hui, A ;
Campbell, RSD .
SKELETAL RADIOLOGY, 2000, 29 (10) :583-586