Blood volume determination by the carbon monoxide method using a new delivery system:: Accuracy in critically ill humans and precision in an animal model

被引:23
作者
Dingley, J [1 ]
Foëx, BA
Swart, M
Findlay, G
DeSouza, PR
Wardrop, C
Willis, N
Smithies, M
Little, RA
机构
[1] Univ Wales Hosp, Dept Anesthet & Intens Care Med, Cardiff, S Glam, Wales
[2] Univ Wales Hosp, Dept Hematol, Cardiff, S Glam, Wales
[3] Univ Wales Hosp, Dept Biochem, Cardiff, S Glam, Wales
[4] Univ Manchester, NW Injury Res Ctr, Manchester, Lancs, England
关键词
blood volume; carbon monoxide; carboxyhemoglobin; indicator dilution; measurement; monitoring; intensive care; critical illness; intermittent positive-pressure ventilation;
D O I
10.1097/00003246-199911000-00019
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To evaluate accuracy and repeatability of blood volume determinations made by the carbon monoxide method, using a ventilator-driven administration system. Design: Prospective within-patient comparison, using simultaneous measurements by two methods to determine accuracy. Prospective laboratory investigation in animals to estimate repeatability. Subjects: For accuracy: Nineteen ventilated critically ill patients in a university hospital intensive care unit, For repeatability: Six anesthetized, mechanically ventilated normovolemic pigs because this is impossible to perform in humans. Interventions: In the accuracy study, a small mass of carbon monoxide was administered via a closed breathing system and arterial blood samples were taken from existing cannulas, In the repeatability study, an intramuscular sedative was given, followed by an inhalational anesthetic induction and mechanical ventilation via a tracheal tube, Left axillary artery and external jugular vein cannulas were sited, Anesthesia was maintained using an intravenous infusion. Five sequential circulating hemoglobin and blood volume estimations were made using the carbon monoxide method. Measurements and Main Results: The small carboxyhemoglobin increase produced by uptake of a small, known mass of carbon monoxide was used to estimate the circulating blood volume. Simultaneous measurement, using Cr-51-labeled red blood cells, was performed. Twenty measurements were made in 19 patients. The bias (mean difference between blood volume measurements by tbe two methods) was 397 mL (5.53 mL . kg(-1)) +/- 415 mL (+/- 5.95 mL . kg(-1)); the limits of agreement (mean difference +/- 2 SO) were -433 mt and 1227 mL (-6.36 mL . kg(-1) and 17.42 mL . kg(-1)). Therefore, 95% of expected differences will lie between these limits, The mean blood volume was 75.8 mL . kg(-1) in the animals. The coefficient of variation of repeated estimates was 9.49%, Mean circulating hemoglobin mass was 7.31 mmol with a coefficient of variation of 10.18%. The mean hemoglobin concentration, by co-oximetry, was 5.014 mmol.L-1, coefficient of variation, 2.99%. Conclusion: This arrangement is a potential bedside method of estimating blood volume and circulating hemoglobin mass, We have rendered the technique more acceptable clinically by creating a ventilator-driven administration system.
引用
收藏
页码:2435 / 2441
页数:7
相关论文
共 24 条
[1]   MEASUREMENT OF PLASMA-VOLUME IN NEONATES [J].
ANTHONY, MY ;
GOODALL, SR ;
PAPOULI, M ;
LEVENE, MI .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1992, 67 (01) :36-40
[2]   INITIAL PLASMA DISAPPEARANCE AND DISTRIBUTION VOLUME OF [I-131]ALBUMIN AND [I-125]FIBRINOGEN IN MAN [J].
BENTHANSEN, L .
ACTA PHYSIOLOGICA SCANDINAVICA, 1989, 136 (03) :455-461
[3]   INHALED NITRIC-OXIDE REDUCES PULMONARY TRANSVASCULAR ALBUMIN FLUX IN PATIENTS WITH ACUTE LUNG INJURY [J].
BENZING, A ;
BRAUTIGAM, P ;
GEIGER, K ;
LOOP, T ;
BEYER, U ;
MOSER, E .
ANESTHESIOLOGY, 1995, 83 (06) :1153-1161
[4]   DISTRIBUTION OF HBCO IN HUMAN ERYTHROCYTES FOLLOWING INHALATION OF CO [J].
BLACKMORE, DJ .
NATURE, 1970, 227 (5256) :386-+
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   ACCURACY OF A NEW BEDSIDE METHOD FOR ESTIMATION OF CIRCULATING BLOOD-VOLUME [J].
CHRISTENSEN, P ;
RASMUSSEN, JW ;
HENNEBERG, SW .
CRITICAL CARE MEDICINE, 1993, 21 (10) :1535-1540
[7]   PRECISION OF A NEW BEDSIDE METHOD FOR ESTIMATION OF THE CIRCULATING BLOOD-VOLUME [J].
CHRISTENSEN, P ;
ERIKSEN, B ;
HENNEBERG, SW .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1993, 37 (06) :622-627
[8]  
DINGLEY J, 1995, INTENSIVE CARE ME S1, V21, pS83
[9]   The suspension stability of the blood [J].
Fahraeus, R .
PHYSIOLOGICAL REVIEWS, 1929, 9 (02) :241-274
[10]   DIODE-ARRAY SPECTROPHOTOMETRY FOR SIMULTANEOUS MEASUREMENT OF HEMOGLOBIN PIGMENTS [J].
FOGHANDERSEN, N ;
SIGGAARDANDERSEN, O ;
LUNDSGAARD, FC ;
WIMBERLEY, PD .
CLINICA CHIMICA ACTA, 1987, 166 (2-3) :283-289