Linac-integrated 4D cone beam CT:: first experimental results

被引:143
作者
Dietrich, Lars [1 ]
Jetter, Siri [1 ]
Tuecking, Thomas [1 ]
Nill, Simeon [1 ]
Oelfke, Uwe [1 ]
机构
[1] German Canc Res Ctr, Dept Med Phys, D-69120 Heidelberg, Germany
关键词
D O I
10.1088/0031-9155/51/11/017
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
A new online imaging approach, linac-integrated cone beam CT (CBCT), has been developed over the past few years. It has the advantage that a patient can be examined in their treatment position directly before or during a radiotherapy treatment. Unfortunately, respiratory organ motion, one of the largest intrafractional organ motions, often leads to artefacts in the reconstructed 3D images. One way to take this into account is to register the breathing phase during image acquisition for a phase-correlated image reconstruction. Therefore, the main focus of this work is to present a system which has the potential to investigate the correlation between internal (movement of the diaphragm) and external (data of a respiratory gating system) information about breathing phase and amplitude using an inline CBCT scanner. This also includes a feasibility study about using the acquired information for a respiratory-correlated 4D CBCT reconstruction. First, a moving lung phantom was used to develop and to specify the required methods which are based on an image reconstruction using only projections belonging to a certain moving phase. For that purpose, the corresponding phase has to be detected for each projection. In the case of the phantom, an electrical signal allows one to track the movement in real time. The number of projections available for the image reconstruction depends on the breathing phase and the size of the position range from which projections should be used for the reconstruction. The narrower this range is, the better the inner structures can be located, but also the noise of the images increases due to the limited number of projections. This correlation has also been analysed. In a second step, the methods were clinically applied using data sets of patients with lung tumours. In this case, the breathing phase was detected by an external gating system (AZ-733V, Anzai Medical Co.) based on a pressure sensor attached to the patient's abdominal region with a fixation belt. The comparison of the reconstructed 4D CBCT images and the corresponding 4D CT images used for the treatment planning provides the required information for the calculation of possible setup errors.
引用
收藏
页码:2939 / 2952
页数:14
相关论文
共 13 条
[1]
Compensation for respiratory motion by gated radiotherapy:: an experimental study [J].
Dietrich, L ;
Tücking, T ;
Nill, S ;
Oelfke, U .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (10) :2405-2414
[2]
EBERT M, 2001, THESIS U MANNHEIM
[3]
PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[4]
The correlation between internal and external markers for abdominal tumors: Implications for respiratory gating [J].
Gierga, DP ;
Brewer, J ;
Sharp, GC ;
Betke, M ;
Willett, CG ;
Chen, GTY .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (05) :1551-1558
[5]
Flat-panel cone-beam computed tomography for image-guided radiation therapy [J].
Jaffray, DA ;
Siewerdsen, JH ;
Wong, JW ;
Martinez, AA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05) :1337-1349
[6]
A method for incorporating organ motion due to breathing into 3D dose calculations [J].
Lujan, AE ;
Larsen, EW ;
Balter, JM ;
Ten Haken, RK .
MEDICAL PHYSICS, 1999, 26 (05) :715-720
[7]
Online correction for respiratory motion: evaluation of two different imaging geometries [J].
Nill, S ;
Unkelbach, J ;
Dietrich, L ;
Oelfke, U .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (17) :4087-4096
[8]
Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy [J].
Seppenwoolde, Y ;
Shirato, H ;
Kitamura, K ;
Shimizu, S ;
van Herk, M ;
Lebesque, JV ;
Miyasaka, K .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (04) :822-834
[9]
A simple, direct method for X-ray scatter estimation and correction in digital radiography and cone-beam CT [J].
Siewerdsen, JH ;
Daly, MJ ;
Bakhtiar, B ;
Moseley, DJ ;
Richard, S ;
Keller, H ;
Jaffray, DA .
MEDICAL PHYSICS, 2006, 33 (01) :187-197
[10]
Respiratory correlated cone beam CT [J].
Sonke, JJ ;
Zijp, L ;
Remeijer, P ;
van Herk, M .
MEDICAL PHYSICS, 2005, 32 (04) :1176-1186