Evaluation and optimization of capillary zone electrophoresis with different dynamic capillary coatings for the determination of carbohydrate-deficient transferrin in human serum

被引:52
作者
Lanz, C
Kuhn, M
Bortolotti, F
Tagliaro, F
Thormann, W
机构
[1] Univ Bern, Dept Clin Pharmacol, CH-3010 Bern, Switzerland
[2] Univ Verona, Dept Publ Med & Hlth, Unit Forens Med, I-37100 Verona, Italy
关键词
capillary electrophoresis; coated capillaries; transferrin; protein;
D O I
10.1016/S0021-9673(02)01244-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Serum transferrin (Tf) comprises several isoforms with up to two complex oligosaccharide chains containing zero to eight sialic acid residues and neutral sugars. The major glycoform, known as tetrasialo-Tf, contains four sialic acid residues and accounts for about 80% of whole Tf in human serum. Carbohydrate-deficient transferrin (CDT) encompasses isoforms that are deficient in carbohydrate chains and consequently in sialic acid residues (including asialo-, monosialo- and disialo-Tf) and is a well known marker for chronic alcohol abuse. Recently capillary zone electrophoresis (CZE) has been reported as a tool extremely effective for the simultaneous, individual, quantitative determination of CDT isoforms. Three CZE methods that feature different dynamic capillary coatings were evaluated and optimized for CDT determination in human serum of alcohol abusers and control subjects. CZE separation was performed in alkaline borate buffers after serum sample saturation with iron, electropherograms were detected at 200 nm, data were evaluated as % area of disialo-Tf in relation to tetrasialo-Tf and peak identification was accomplished via relative migration times to tetrasialo-Tf, immunosubtraction and enzymatic sequential cleavage of sialic acid residues. Dynamic capillary coatings with diaminobutane, spermine and a double coating produced by commercially available proprietary agents were investigated and found to be suitable for determination of CDT in human serum. For all three approaches, best results were obtained in 50 mum I.D. fused-silica capillaries of 50 cm effective length and a capillary cartridge temperature of 20-25 degreesC. Using 3 mM 1,4-diaminobutane or 0.02 mM spermine in a borate-based running buffer of pH 8.3 provided data of remarkable similarity with resolution of di-, tri-, tetra- and pentasialo-Tf within 15-18 min. With the double coating, asialo-Tf and Tf isoforms with two to six sialic acid residues were baseline separated. Compared to the two amine-based procedures, the run times were found to be somewhat shorter, the detector signals higher, the applied power level significantly lower and the reproducibility better. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:43 / 57
页数:15
相关论文
共 40 条
[1]  
Arndt T, 2001, CLIN CHEM, V47, P13
[2]   Circumventing complement C3 interference in the analysis of carbohydrate-deficient transferrin in fresh serum [J].
Beisler, AT ;
Kelly, RH ;
Landers, JP .
ANALYTICAL BIOCHEMISTRY, 2000, 285 (01) :143-150
[3]   Improved method for carbohydrate-deficient transferrin determination in human serum by capillary zone electrophoresis [J].
Crivellente, F ;
Fracasso, G ;
Valentini, R ;
Manetto, G ;
Riviera, AP ;
Tagliaro, F .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 739 (01) :81-93
[4]   MICROHETEROGENEITY OF HUMAN-SERUM TRANSFERRIN - A BIOLOGICAL PHENOMENON STUDIED BY ISOELECTRIC-FOCUSING IN IMMOBILIZED PH GRADIENTS [J].
DEJONG, G ;
VANEIJK, HG .
ELECTROPHORESIS, 1988, 9 (09) :589-598
[5]   Dynamically-coated capillaries allow for capillary electrophoretic resolution of transferrin sialoforms via direct analysis of human serum [J].
Giordano, BC ;
Muza, M ;
Trout, A ;
Landers, JP .
JOURNAL OF CHROMATOGRAPHY B, 2000, 742 (01) :79-89
[6]   Study of axis-shield new %CDT immunoassay for quantification of carbohydrate-deficient transferrin (CDT) in serum [J].
Helander, A ;
Fors, M ;
Zakrisson, B .
ALCOHOL AND ALCOHOLISM, 2001, 36 (05) :406-412
[7]  
Horvath J, 2001, ELECTROPHORESIS, V22, P644, DOI 10.1002/1522-2683(200102)22:4<644::AID-ELPS644>3.3.CO
[8]  
2-V
[9]  
Inoue T, 1999, ELECTROPHORESIS, V20, P452, DOI 10.1002/(SICI)1522-2683(19990301)20:3<452::AID-ELPS452>3.0.CO
[10]  
2-R