Comparison of PET/CT and PET/MRI hybrid systems using a 68Ga-labelled PSMA ligand for the diagnosis of recurrent prostate cancer: initial experience

被引:270
作者
Afshar-Oromieh, A. [1 ,2 ]
Haberkorn, U. [1 ,3 ]
Schlemmer, H. P. [2 ]
Fenchel, M. [2 ]
Eder, M. [4 ]
Eisenhut, M. [4 ]
Hadaschik, B. A. [5 ]
Kopp-Schneider, A. [6 ]
Roethke, M. [2 ]
机构
[1] Univ Heidelberg Hosp, Dept Nucl Med, D-69120 Heidelberg, Germany
[2] German Canc Res Ctr, Dept Radiol, Heidelberg, Germany
[3] German Canc Res Ctr, Clin Cooperat Unit Nucl Med, Heidelberg, Germany
[4] German Canc Res Ctr, Dept Radiopharmaceut Chem, Heidelberg, Germany
[5] Univ Heidelberg Hosp, Dept Urol, D-69120 Heidelberg, Germany
[6] German Canc Res Ctr, Dept Biostat, Heidelberg, Germany
关键词
Prostate cancer; PET/CT; PET/MRI; PSMA; Prostate-specific membrane antigen; EMISSION TOMOGRAPHY/COMPUTED TOMOGRAPHY; MEMBRANE ANTIGEN; INHIBITOR; F-18-FLUOROCHOLINE; RESONANCE; RELAPSE; DISEASE;
D O I
10.1007/s00259-013-2660-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Ga-68-labelled HBED-CC-PSMA is a highly promising tracer for imaging recurrent prostate cancer (PCa). The intention of this study was to evaluate the feasibility of PET/MRI with this tracer. Twenty patients underwent PET/CT 1 h after injection of the Ga-68-PSMA ligand followed by PET/MRI 3 h after injection. Data from the two investigations were first analysed separately and then compared with respect to tumour detection rate and radiotracer uptake in various tissues. To evaluate the quantification accuracy of the PET/MRI system, differences in SUVs between PET/CT and corresponding PET/MRI were compared with differences in SUVs between PET/CT 1 h and 3 h after injection in another patient cohort. This cohort was investigated using the same PET/CT system. With PET/MRI, different diagnostic sequences, higher contrast of lesions and higher resolution of MRI enabled a subjectively easier evaluation of the images. In addition, four unclear findings on PET/CT could be clarified as characteristic of PCa metastases by PET/MRI. However, in PET images of the PET/MRI, a reduced signal was observed at the level of the kidneys (in 11 patients) and around the urinary bladder (in 15 patients). This led to reduced SUVs in six lesions. SUVmean values provided by the PET/MRI system were different in muscles, blood pool, liver and spleen. PCa was detected more easily and more accurately with Ga-PSMA PET/MRI than with PET/CT and with lower radiation exposure. Consequently, this new technique could clarify unclear findings on PET/CT. However, scatter correction was challenging when the specific Ga-68-PSMA ligand was used. Moreover, direct comparison of SUVs from PET/CT and PET/MR needs to be conducted carefully.
引用
收藏
页码:887 / 897
页数:11
相关论文
共 25 条
[1]   PET imaging with a [68Ga]gallium-labelled PSMA ligand for the diagnosis of prostate cancer: biodistribution in humans and first evaluation of tumour lesions [J].
Afshar-Oromieh, A. ;
Malcher, A. ;
Eder, M. ;
Eisenhut, M. ;
Linhart, H. G. ;
Hadaschik, B. A. ;
Holland-Letz, T. ;
Giesel, F. L. ;
Kratochwil, C. ;
Haufe, S. ;
Haberkorn, U. ;
Zechmann, C. M. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 (04) :486-495
[2]   [68Ga]Gallium-labelled PSMA ligand as superior PET tracer for the diagnosis of prostate cancer: comparison with 18F-FECH [J].
Afshar-Oromieh, A. ;
Haberkorn, U. ;
Eder, M. ;
Eisenhut, M. ;
Zechmann, C. M. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 (06) :1085-1086
[3]   Comparison of PET imaging with a 68Ga-labelled PSMA ligand and 18F-choline-based PET/CT for the diagnosis of recurrent prostate cancer [J].
Afshar-Oromieh, Ali ;
Zechmann, Christian M. ;
Malcher, Anna ;
Eder, Matthias ;
Eisenhut, Michael ;
Linhart, Heinz G. ;
Holland-Letz, Tim ;
Hadaschik, Boris A. ;
Giesel, Frederik L. ;
Debus, Juergen ;
Haberkorn, Uwe .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (01) :11-20
[4]   PET/MRI with a 68Ga-PSMA ligand for the detection of prostate cancer [J].
Afshar-Oromieh, Ali ;
Haberkorn, Uwe ;
Hadaschik, Boris ;
Habl, Gregor ;
Eder, Matthias ;
Eisenhut, Michael ;
Schlemmer, Heinz-Peter ;
Roethke, Matthias C. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 (10) :1629-1630
[5]   Sensitivity of PET/MRI to detect recurrence of prostate cancer [J].
Arce-Calisaya, Patricia ;
Souvatzoglou, Michael ;
Eiber, Mathias ;
Beer, Ambros ;
Scheidhauer, Klemens ;
Geinitz, Hans ;
Schwaiger, Markus .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 (05) :799-799
[6]   2-(3-{1-Carboxy-5-[(6-[18F]Fluoro-Pyridine-3-Carbonyl)-Amino]-Pentyl}-Ureido)-Pentanedioic Acid, [18F]DCFPyL, a PSMA-Based PET Imaging Agent for Prostate Cancer [J].
Chen, Ying ;
Pullambhatla, Mrudula ;
Foss, Catherine A. ;
Byun, Youngjoo ;
Nimmagadda, Sridhar ;
Senthamizhchelvan, Srinivasan ;
Sgouros, George ;
Mease, Ronnie C. ;
Pomper, Martin G. .
CLINICAL CANCER RESEARCH, 2011, 17 (24) :7645-7653
[7]   [18F]fluorocholine PET/CT imaging for the detection of recurrent prostate cancer at PSA relapse:: experience in 100 consecutive patients [J].
Cimitan, Marino ;
Bortolus, Roberto ;
Morassut, Sandro ;
Canzonieri, Vincenzo ;
Garbeglio, Antonio ;
Baresic, Tanja ;
Borsatti, Eugenio ;
Drigo, Annalisa ;
Trovo, Mauro G. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 (12) :1387-1398
[8]   PSMA as a target for radiolabelled small molecules [J].
Eder, Matthias ;
Eisenhut, Michael ;
Babich, John ;
Haberkorn, Uwe .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 (06) :819-823
[9]   68Ga-Complex Lipophilicity and the Targeting Property of a Urea-Based PSMA Inhibitor for PET Imaging [J].
Eder, Matthias ;
Schaefer, Martin ;
Bauder-Wuest, Ulrike ;
Hull, William-Edmund ;
Waengler, Carmen ;
Mier, Walter ;
Haberkorn, Uwe ;
Eisenhut, Michael .
BIOCONJUGATE CHEMISTRY, 2012, 23 (04) :688-697
[10]   Evaluation of Feasibility and Image Quality of 68Ga-DOTATOC Positron Emission Tomography/Magnetic Resonance in Comparison With Positron Emission Tomography/Computed Tomography in Patients With Neuroendocrine Tumors [J].
Gaertner, Florian C. ;
Beer, Ambros J. ;
Souvatzoglou, Michael ;
Eiber, Matthias ;
Fuerst, Sebastian ;
Ziegler, Sybille I. ;
Brohl, Florian ;
Schwaiger, Markus ;
Scheidhauer, Klemens .
INVESTIGATIVE RADIOLOGY, 2013, 48 (05) :263-272