Non-invasive beat-to-beat cardiac output monitoring by an improved method of transthoracic bioimpedance measurement

被引:191
作者
Fortin, J.
Habenbacher, W.
Heller, A.
Hacker, A.
Gruellenberger, R.
Innerhofer, J.
Passath, H.
Wagner, Ch.
Haitchi, G.
Flotzinger, D.
Pacher, R.
Wach, P.
机构
[1] Graz Univ Technol, Inst Med Engn, A-8010 Graz, Austria
[2] Karl Franzens Univ Graz, Teaching Hosp Barmherzige Brueder, Dept Internal Med, A-8020 Graz, Austria
[3] Univ Vienna, Dept Cardiol, A-1090 Vienna, Austria
基金
奥地利科学基金会;
关键词
non-invasive cardiac output; non-invasive stroke volume; impedance cardiography; Kubicek principle; transthoracic bioimpedance;
D O I
10.1016/j.compbiomed.2005.06.001
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The report describes a method of impedance cardiography using an improved estimate of thoracic volume. The formulas and their implementation in hardware and software are explained and new shortband electrodes are described which generate a good homogeneous thoracic field. Examples of stroke volume and cardiac output curves underline the capabilities of the monitoring system "Task Force (R) Monitor". In several experiments, results are compared to thermodilution as well as to BioZ measurements: the new method excels in comparison with thermodilution and is comparable to the BioZ device. Compared to traditional electrodes, the new shorthand electrodes are shown to provide better reproducibility. (c) 2005 Published by Elsevier Ltd.
引用
收藏
页码:1185 / 1203
页数:19
相关论文
共 31 条
[1]  
[Anonymous], 2000, Paleontological Society Papers
[2]  
[Anonymous], 1998, Clinical guidelines on the identification, evaluation, and treatment of overweight and obesity in adults: The evidence report
[3]  
ATZLER E., 1932, ARBEITSPHYSIOLOGIE, V5, P636
[4]   Acute hemodynamic improvement by pacing in patients with severe congestive heart failure [J].
Auricchio, A ;
Salo, RW .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (02) :313-324
[5]   Effect of pacing chamber and atrioventricular delay on acute systolic function of paced patients with congestive heart failure [J].
Auricchio, A ;
Stellbrink, C ;
Block, M ;
Sack, S ;
Vogt, J ;
Bakker, P ;
Klein, H ;
Kramer, A ;
Ding, J ;
Salo, R ;
Tockman, B ;
Pochet, T ;
Spinelli, J .
CIRCULATION, 1999, 99 (23) :2993-3001
[6]   CONTINUOUS NONINVASIVE REAL-TIME MONITORING OF STROKE VOLUME AND CARDIAC-OUTPUT BY THORACIC ELECTRICAL BIOIMPEDANCE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :898-901
[7]   A NEW STROKE VOLUME EQUATION FOR THORACIC ELECTRICAL BIOIMPEDANCE - THEORY AND RATIONALE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :904-909
[8]   A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques [J].
Critchley, LAH ;
Critchley, JAJH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) :85-91
[9]  
DEMARIA AN, 2000, CONGESTIVE HEART FAI, V6, P7
[10]   Comparison of impedance cardiography with invasive hemodynamic measurements in patients with heart failure secondary to ischemic or nonischemic cardiomyopathy [J].
Drazner, MH ;
Thompson, B ;
Rosenberg, PB ;
Kaiser, PA ;
Boehrer, JD ;
Baldwin, BJ ;
Dries, DL ;
Yancy, CW .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (08) :993-+