Adverse Bioeffects of Ultrasound Contrast Agents Used in Echocardiography: True Safety Issue or "Much Ado About Nothing"?

被引:11
作者
Aggeli, Constadina [1 ]
Giannopoulos, Georgios [1 ]
Lampropoulos, Konstantinos [1 ]
Pitsavos, Christos [1 ]
Stefanadis, Christodoulos [1 ]
机构
[1] Univ Athens, Sch Med, Dept Cardiol 1, Hippokration Hosp, GR-11527 Athens, Greece
关键词
Ultrasound contrast agents; contrast echocardiography; coronary artery disease; safety; DOBUTAMINE STRESS ECHOCARDIOGRAPHY; ACUTE MYOCARDIAL-INFARCTION; PREMATURE VENTRICULAR CONTRACTIONS; CORONARY-ARTERY-DISEASE; BLOOD-BRAIN-BARRIER; MICROBUBBLE DESTRUCTION; PERFUSION DEFECTS; DIAGNOSTIC ULTRASOUND; COMPARATIVE ACCURACY; PULSED ULTRASOUND;
D O I
10.2174/157016109788340695
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Ultrasound contrast agents, consisting of gas-filled microbubbles, have long been used to enhance ultrasonographic imaging of various organs and in several settings. In echocardiography, after their first use for Doppler signal enhancement, their applications have expanded and several studies, combining a range of stress modalities with myocardial contrast echocardiography have shown the clinical utility of these agents. In experimental isolated heart animal models, the interaction of ultrasound with echo-contrast microbubbles was shown to have significant biologic effects when the acoustic energy of the beam exceeded a threshold, leading them to rupture and causing cavitation phenomena; the observed consequences in the experimental setting included microvascular damage, transient decrease of contractile performance and increased lactate production. From the clinical point of view, the reporting of a number of serious adverse events-whose association with the echo-contrast agents was debated-has led to the addition of warning boxes in the prescribing documentation of these preparations. On the other hand, clinical studies including high numbers of patients have shown good safety and tolerance of contrast use during stress echocardiography, both for left ventricle opacification and myocardial perfusion imaging. The present review aims at presenting a balanced account of the existing data regarding the mechanisms and clinical implications of echo-contrast bioeffects, in order to make an informed assessment of their safety in clinical practice.
引用
收藏
页码:338 / 346
页数:9
相关论文
共 75 条
[61]   FUNCTIONAL-SIGNIFICANCE OF COLLATERAL BLOOD-FLOW IN PATIENTS WITH RECENT ACUTE MYOCARDIAL-INFARCTION - A STUDY USING MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY [J].
SABIA, PJ ;
POWERS, ER ;
JAYAWEERA, AR ;
RAGOSTA, M ;
KAUL, S .
CIRCULATION, 1992, 85 (06) :2080-2089
[62]   Observation on the integrity of the blood-brain barrier after microbubble destruction by diagnostic transcranial color-coded sonography [J].
Schlachetzki, F ;
Hölscher, T ;
Koch, HJ ;
Draganski, B ;
May, A ;
Schuierer, G ;
Bogdahn, U .
JOURNAL OF ULTRASOUND IN MEDICINE, 2002, 21 (04) :419-429
[63]   Myocardial perfusion assessment in patients with medium probability of coronary artery disease and no prior myocardial infarction:: Comparison of myocardial contrast echocardiography with 99mTc single-photon emission computed tomography [J].
Senior, R ;
Lepper, W ;
Pasquet, A ;
Chung, G ;
Hoffman, R ;
Vanoverschelde, JL ;
Cerqueira, M ;
Kaul, S .
AMERICAN HEART JOURNAL, 2004, 147 (06) :1100-1105
[64]   Real-time assessment of myocardial perfusion and wall motion during bicycle and treadmill exercise echocardiography: Comparison with single photon emission computed tomography [J].
Shimoni, S ;
Zoghbi, WA ;
Xie, F ;
Kricsfeld, D ;
Iskander, S ;
Gobar, L ;
Mikati, IA ;
Abukhalil, J ;
Verani, MS ;
O'Leary, EL ;
Porter, TR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (03) :741-747
[65]   Direct in vivo visualization of intravascular destruction of microbubbles by ultrasound and its local effects on tissue [J].
Skyba, DM ;
Price, RJ ;
Linka, AZ ;
Skalak, TC ;
Kaul, S .
CIRCULATION, 1998, 98 (04) :290-293
[66]   Hemodynamic characteristics, myocardial kinetics and microvascular rheology of FS-069, a second-generation echocardiographic contrast agent capable of producing myocardial opacification from a venous injection [J].
Skyba, DM ;
Camarano, G ;
Goodman, NC ;
Price, RJ ;
Skalak, TC ;
Kaul, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (05) :1292-1300
[67]   Stimulation of arteriogenesis in skeletal muscle by microbubble destruction with ultrasound [J].
Song, J ;
Qi, M ;
Kaul, S ;
Price, RJ .
CIRCULATION, 2002, 106 (12) :1550-1555
[68]   Safety of dobutamine stress real-time myocardial contrast echocardiography [J].
Tsutsui, JM ;
Elhendy, A ;
Xie, F ;
O'Leary, EL ;
McGrain, AC ;
Porter, TR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (08) :1235-1242
[69]   Prognostic value of dobutamine stress myocardial contrast perfusion echocardiography [J].
Tsutsui, JM ;
Elhendy, A ;
Anderson, JR ;
Xie, F ;
McGrain, AC ;
Porter, TR .
CIRCULATION, 2005, 112 (10) :1444-1450
[70]   Local drug and gene delivery through microbubbles [J].
Unger, EC ;
Hersh, E ;
Vannan, M ;
Matsunaga, TO ;
McCreery, M .
PROGRESS IN CARDIOVASCULAR DISEASES, 2001, 44 (01) :45-54