In situ measurement and modeling of biomechanical response of human cadaveric soft tissues for physics-based surgical simulation

被引:78
作者
Lim, Yi-Je
Deo, Dhanannjay [1 ]
Singh, Tejinder P. [2 ]
Jones, Daniel B. [3 ]
De, Suvranu [1 ]
机构
[1] Rensselaer Polytech Inst, Dept Mech Aerosp & Nucl Engn, Troy, NY 12180 USA
[2] Albany Med Coll, Dept Surg, Albany, NY 12208 USA
[3] Beth Israel Deaconess Med Ctr, Dept Surg, Boston, MA 02215 USA
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2009年 / 23卷 / 06期
关键词
Surgical simulation; Soft tissue; Biomechanical properties; Human cadaver; Indentation experiments; MECHANICAL-PROPERTIES; VIRTUAL ENVIRONMENTS; VISCOELASTIC PROPERTIES; ELASTIC PROPERTIES; VIVO MEASUREMENT; SURGERY; LAPAROSCOPY; HAPTICS; TIME;
D O I
10.1007/s00464-008-0154-z
中图分类号
R61 [外科手术学];
学科分类号
摘要
Development of a laparoscopic surgery simulator that delivers high-fidelity visual and haptic (force) feedback, based on the physical models of soft tissues, requires the use of empirical data on the mechanical behavior of intra-abdominal organs under the action of external forces. As experiments on live human patients present significant risks, the use of cadavers presents an alternative. We present techniques of measuring and modeling the mechanical response of human cadaveric tissue for the purpose of developing a realistic model. The major contribution of this paper is the development of physics-based models of soft tissues that range from linear elastic models to nonlinear viscoelastic models which are efficient for application within the framework of a real-time surgery simulator. To investigate the in situ mechanical, static, and dynamic properties of intra-abdominal organs, we have developed a high-precision instrument by retrofitting a robotic device from Sensable Technologies (position resolution of 0.03 mm) with a six-axis Nano 17 force-torque sensor from ATI Industrial Automation (force resolution of 1/1,280 N along each axis), and used it to apply precise displacement stimuli and record the force response of liver and stomach of ten fresh human cadavers. The mean elastic modulus of liver and stomach is estimated as 5.9359 kPa and 1.9119 kPa, respectively over the range of indentation depths tested. We have also obtained the parameters of a quasilinear viscoelastic (QLV) model to represent the nonlinear viscoelastic behavior of the cadaver stomach and liver over a range of indentation depths and speeds. The models are found to have an excellent goodness of fit (with R (2) > 0.99). The data and models presented in this paper together with additional ones based on the principles presented in this paper would result in realistic physics-based surgical simulators.
引用
收藏
页码:1298 / 1307
页数:10
相关论文
共 48 条
[41]  
TAY B, 2002, IN VIVO FORCE RESPON
[42]   In vivo mechanical behavior of intra-abdominal organs [J].
Tay, Boon K. ;
Kim, Jung ;
Srinivasan, Mandayarn A. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (11) :2129-2138
[43]   A virtual environment testbed for training laparoscopic surgical skills [J].
Tendick, F ;
Downes, M ;
Goktekin, T ;
Cavusoglu, MC ;
Feygin, D ;
Wu, XL ;
Eyal, R ;
Hegarty, M ;
Way, LW .
PRESENCE-VIRTUAL AND AUGMENTED REALITY, 2000, 9 (03) :236-255
[44]  
TORRESMORENO R, 1991, THESIS U STRATHCLYDE
[45]  
VIIDIK A, 1978, P S AC AARH LOND
[46]   SOME FORMS OF THE STRAIN-ENERGY FUNCTION FOR RUBBER [J].
YEOH, OH .
RUBBER CHEMISTRY AND TECHNOLOGY, 1993, 66 (05) :754-771
[47]  
Zheng Y, 1999, IEEE Trans Rehabil Eng, V7, P257, DOI 10.1109/86.788463
[48]   An ultrasound indentation system for biomechanical properties assessment of soft tissues in-vivo [J].
Zheng, YP ;
Mak, AFT .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (09) :912-918