Method development for the determination of thallium in coal using solid sampling graphite furnace atomic absorption spectrometry with continuum source, high-resolution monochromator and CCD array detector

被引:67
作者
Silva, AF
Borges, DLG
Welz, B
Vale, MGR
Silva, MM
Klassen, A
Heitmann, U
机构
[1] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
[2] ISAS, Inst Analyt Sci, Dept Berlin, D-12489 Berlin, Germany
[3] Univ Fed Rio Grande do Sul, Inst Quim, BR-91501900 Porto Alegre, RS, Brazil
关键词
high-resolution continuum-source atomic absorption spectrometry; solid sample analysis; electrothermal atomization; thallium determination; coal analysis;
D O I
10.1016/j.sab.2004.03.001
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The determination of thallium by graphite furnace atomic absorption spectrometry (GFAAS) is plagued by several difficult-to-control interferences. High-resolution continuum-source GFAAS, a technique not yet commercially available, was used to investigate and eliminate spectral interferences, and to develop a reliable method for the determination of thallium in coal using direct solid sampling. The resolution of 2.1 pm per pixel, and the display of the spectral environment +/-0.2 nm on both sides of the analytical line were ideally suited for that purpose. The thallium signal was preceded by excessive non-specific absorption due to the coal matrix when pyrolysis temperatures less than or equal to600 degreesC were used, and a characteristic molecular absorption with pronounced fine structure was following the atomic absorption. With a pyrolysis temperature of 700 degreesC the non-specific absorption at the beginning of the atomization stage could be eliminated, and using an atomization temperature of 1700 degreesC, and no modifier, the atomic absorption could be separated in wavelength and in time from the molecular structures, making possible an interference-free determination of thallium, using Pixel 260 at 276.8085 mn for background correction. The results obtained for 11 coal samples and one coal fly ash were in agreement at a 95% confidence level without a modifier, with palladium added in solution, and with ruthenium as permanent modifier, respectively, using aqueous standards for calibration. A characteristic mass of m(0) = 12 pg and 5.5 pg was obtained with the center pixel only, and the center pixel +/-1, respectively. The precision, expressed as relative standard deviation was typically better than 5%, and the limit of detection, based on three times the standard deviation of the coal with the lowest analyte content, was 0.01 mug g(-1). (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:841 / 850
页数:10
相关论文
共 25 条
[1]   Observation, identification and correction of structured molecular background by means of continuum source AAS - determination of selenium and arsenic in human urine [J].
Becker-Ross, H ;
Florek, S ;
Heitmann, U .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (02) :137-141
[2]   Direct solid sampling with electrothermal vaporization/atomization: what for and how? [J].
Belarra, MA ;
Resano, M ;
Vanhaecke, F ;
Moens, L .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2002, 21 (12) :828-839
[3]  
CARSON BL, 1986, TOXICOLOGY BIOL MONI, P243
[4]  
CLARKE LB, 1992, TRACE ELEMENTS EMISS, pCH2
[5]   Noble metals as permanent chemical modifiers for the determination of mercury in environmental reference materials using solid sampling graphite furnace atomic absorption spectrometry and calibration against aqueous standards [J].
da Silva, AF ;
Welz, B ;
Curtius, AJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (12) :2031-2045
[6]   ICP-MS DETERMINATION OF 45 TRACE-ELEMENTS IN WHOLE COAL USING MICROWAVE-OVEN ACID DIGESTION FOR SAMPLE PREPARATION [J].
FADDA, S ;
RIVOLDINI, A ;
CAU, I .
GEOSTANDARDS NEWSLETTER, 1995, 19 (01) :41-54
[7]  
Falbe J., 1992, ROMPP CHEM LEXIKON, V6, P4549
[8]  
Figueroa LB, 1997, ATOM SPECTROSC, V18, P13
[9]   Measurements on the Zeeman-splitting of analytical lines by means of a continuum source graphite furnace atomic absorption spectrometer with a linear charge coupled device array [J].
Heitmann, U ;
Schutz, M ;
BeckerRoss, H ;
Florek, S .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (9-10) :1095-1105
[10]   MINIMIZATION OF BACKGROUND CORRECTION ERRORS USING NONLINEAR ESTIMATES OF THE CHANGING BACKGROUND IN CARBON FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
HOLCOMBE, JA ;
HARNLY, JM .
ANALYTICAL CHEMISTRY, 1986, 58 (13) :2606-2611