Electrode design for coplanar-grid detectors

被引:29
作者
Luke, PN [1 ]
Amman, M [1 ]
Prettyman, TH [1 ]
Russo, PA [1 ]
Close, DA [1 ]
机构
[1] LOS ALAMOS NATL LAB,LOS ALAMOS,NM 87545
关键词
D O I
10.1109/23.603739
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The coplanar-grid charge sensing technique provides a method for improving the spectral response of gamma-ray detectors based on compound semiconductors, which typically have poor charge transport properties. The technique functions by effectively modifying the charge induction characteristics of the detector such that the dependence of detector signal on the depth of radiation interaction is minimized. The effectiveness of this technique however can be compromised by non-uniform charge induction characteristics across the detector. This paper examines such non-uniformity due to fringe effects near the detector edges. Alternate electrode configurations are studied that provide effective compensation for such effects. Results from experimental measurements and computer simulations are presented.
引用
收藏
页码:713 / 720
页数:8
相关论文
共 7 条
[1]   CD1-XZNXTE4 GAMMA-RAY DETECTORS [J].
BUTLER, JF ;
LINGREN, CL ;
DOTY, FP .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :605-609
[2]   UNIPOLAR CHARGE SENSING WITH COPLANAR ELECTRODES - APPLICATION TO SEMICONDUCTOR-DETECTORS [J].
LUKE, PN .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :207-213
[3]   Performance of CdZnTe coplanar-grid gamma-ray detectors [J].
Luke, PN ;
Eissler, EE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :1481-1486
[4]  
PRETTYMAN T, IN PRESS J APPL RAD
[5]  
PRETTYMAN T, 1996, P JOINT ESARDAINMM W
[6]  
Ramo S., 1939, Proc. IRE, V27, P584, DOI [DOI 10.1109/JRPROC.1939.228757, 10.1109/JRPROC.1939.228757]
[7]  
SAKAI E, 1982, NUCL INSTRUM METHODS, V196, P121, DOI 10.1016/0029-554X(82)90626-7