On-line coupling of capillary electrophoresis to hydride generation atomic fluorescence spectrometry for arsenic speciation analysis

被引:77
作者
Yin, XB [1 ]
Yan, XP [1 ]
Jiang, Y [1 ]
He, XW [1 ]
机构
[1] Nankai Univ, Coll Chem, Res Ctr Analyt Sci, Cent Lab, Tianjin 300071, Peoples R China
关键词
D O I
10.1021/ac025735w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel hyphenated technique, on-line coupling of capillary electrophoresis (CE) to atomic fluorescence spectrometry (AFS), was developed for speciation analysis of four environmentally significant and toxic forms of arsenic: arsenite, arsenate, monomethylarsenic acid, and dimethylarsenic acid. Baseline separation of the four arsenic species was achieved by capillary electrophoresis in a 50 cm x 100 mum W. fused-silica capillary at 20 kV and using a 20 mmol L-1 phosphate buffer (pH 6.5). A hydride generation (HG) technique was employed to convert the arsenic species from the CE effluent into their respective hydrides. The CE-AFS interface was constructed on the basis of a cross design for introducing a sheath flow around the CE capillary and a Pt electrode, which provided an electrical connection for stable electrophoretic separations and allowed on-line volatile hydride formation. A laboratory-made gas-liquid separator was used to isolate the generated volatile species from the reaction mixture solution, and an argon flow was used to transport the volatile hydrides into the atomizer of AFS for on-line detection. The precision (RSD, n = 7) ranged from 2.1 to 3.1% for migration time, from 2.8 to 4.2% for peak area response, and from 2.0 to 4.1% for peak height response for the arsenic species at the 1 mg L-1 (as As) level. The detection limits were in the range of 9-18 mug L-1 (as As). The recoveries of the four arsenic species in locally collected water samples and urine sample ranged from 91 to 115%. The developed technique was successfully applied to the speciation of the water-methanol extractable arsenic in a sediment sample.
引用
收藏
页码:3720 / 3725
页数:6
相关论文
共 44 条
[1]   Evaluation of a microconcentric nebulizer and its suction effect in a capillary electrophoresis interface with inductively coupled plasma mass spectrometry [J].
B'Hymer, C ;
Day, JA ;
Caruso, JA .
APPLIED SPECTROSCOPY, 2000, 54 (07) :1040-1046
[2]   Comparison of a cross-flow and microconcentric nebulizer for chemical speciation measurements using CZE-ICP-MS [J].
Baker, SA ;
Miller-Ihli, NJ .
APPLIED SPECTROSCOPY, 1999, 53 (04) :471-478
[3]   Interfacing capillary electrophoresis with inductively coupled plasma mass spectrometry by direct injection nebulization for selenium speciation [J].
Bendahl, L ;
Gammelgaard, B ;
Jons, O ;
Farver, O ;
Hansen, SH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (01) :38-42
[4]  
CARUSO JA, 2000, ELEMENTAL SPECIATION, pR33
[5]   Optimization of the hyphenation between capillary zone electrophoresis and inductively coupled plasma mass spectrometry for the measurement of As-, Sb-, Se- and Te-species, applicable to soil extracts [J].
Casiot, C ;
Donard, OFX ;
Potin-Gautier, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (01) :173-187
[6]   Interface for capillary electrophoresis coupled with inductively coupled plasma atomic emission spectrometry [J].
Chan, YY ;
Chan, WT .
JOURNAL OF CHROMATOGRAPHY A, 1999, 853 (1-2) :141-149
[7]   Determination of selenomethionine by high performance liquid chromatography-direct hydride generation-atomic absorption spectrometry [J].
Chatterjee, A ;
Shibata, Y ;
Morita, M .
MICROCHEMICAL JOURNAL, 2001, 69 (03) :179-187
[8]   Speciation of mercury using capillary electrophoresis coupled to volatile species generation-inductively coupled plasma mass spectrometry [J].
da Rocha, MS ;
Soldado, AB ;
Blanco, E ;
Sanz-Medel, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (09) :951-956
[9]   Capillary electrophoresis: the state-of-the-art in metal speciation studies [J].
Dabek-Zlotorzynska, E ;
Lai, EPC ;
Timerbaev, AR .
ANALYTICA CHIMICA ACTA, 1998, 359 (1-2) :1-26
[10]   A comparison of capillary electrophoresis using indirect UV absorbance and ICP-MS detection with a self-aspirating nebulizer interface [J].
Day, JA ;
Sutton, KL ;
Soman, RS ;
Caruso, JA .
ANALYST, 2000, 125 (05) :819-823