Modelling an extreme water-lung interface using a single pencil beam algorithm and the Monte Carlo method

被引:25
作者
Cranmer-Sargison, G
Beckham, WA
Popescu, IA
机构
[1] Univ Victoria, Dept Phys & Astron, Victoria, BC V8W 2Y2, Canada
[2] British Columbia Canc Agcy, Vancouver Isl Ctr, Dept Med Phys, Victoria, BC, Canada
关键词
D O I
10.1088/0031-9155/49/8/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The goal of this study was to quantify, in a heterogeneous phantom, the difference between experimentally measured beam profiles and those calculated using both a commercial convolution algorithm and the Monte Carlo (MC) method. This was done by arranging a phantom geometry that incorporated a vertical solid water-lung material interface parallel to the beam axis. At nominal x-ray energies of 6 and 18 MV, dose distributions were modelled for field sizes of 10 x 10 cm(2) and 4 x 4 cm(2) using the CadPlan 6.0 commercial treatment planning system (TPS) and the BEAMnrc-DOSXYZnrc Monte Carlo package. Beam profiles were found experimentally at various depths using film dosimetry, The results showed that within the lung region the TPS had a substantial problem modelling the dose distribution. The (film-TPS) profile difference was found to increase, in the lung region, as the field size decreased and the beam energy increased; in the worst case the difference was more than 15%. In contrast, (film-MC) profile differences were not found to be affected by the material density difference. BEAMnrc-DOSXYZnrc successfully modelled the material interface and dose profiles to within 2%.
引用
收藏
页码:1557 / 1567
页数:11
相关论文
共 29 条
[1]  
ABJORK P, 2002, PHYS MED BIOL, V47, P4019
[2]   A PENCIL BEAM MODEL FOR PHOTON DOSE CALCULATION [J].
AHNESJO, A ;
SAXNER, M ;
TREPP, A .
MEDICAL PHYSICS, 1992, 19 (02) :263-273
[3]   COLLAPSED CONE CONVOLUTION OF RADIANT ENERGY FOR PHOTON DOSE CALCULATION IN HETEROGENEOUS MEDIA [J].
AHNESJO, A .
MEDICAL PHYSICS, 1989, 16 (04) :577-592
[4]   Dose calculations for external photon beams in radiotherapy [J].
Ahnesjö, A ;
Aspradakis, MM .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (11) :R99-R155
[5]  
Bevington P., 2002, Data Reduction and Error Analysis for the Physical Sciences, V3rd ed.
[6]   Interinstitutional variations of sensitometric curves of radiographic dosimetric films [J].
Bos, LJ ;
Danciu, C ;
Cheng, CW ;
Brugmans, MJP ;
van der Horst, A ;
Minken, A ;
Mijnheer, BJ .
MEDICAL PHYSICS, 2002, 29 (08) :1772-1780
[7]   A PHOTON DOSE DISTRIBUTION MODEL EMPLOYING CONVOLUTION CALCULATIONS [J].
BOYER, A ;
MOK, E .
MEDICAL PHYSICS, 1985, 12 (02) :169-177
[8]   CALCULATION OF PHOTON DOSE DISTRIBUTIONS IN AN INHOMOGENEOUS-MEDIUM USING CONVOLUTIONS [J].
BOYER, AL ;
MOK, EC .
MEDICAL PHYSICS, 1986, 13 (04) :503-509
[9]   Variation of sensitometric curves of radiographic films in high energy photon beams [J].
Danciu, C ;
Proimos, BS ;
Rosenwald, JC ;
Mijnheer, BJ .
MEDICAL PHYSICS, 2001, 28 (06) :966-974
[10]  
DING GX, 2002, PHYS MED BIOL, V47, P2256