Postoperative corneal shape changes: Microincision versus small-incision coaxial cataract surgery

被引:130
作者
Hayashi, Ken [1 ]
Yoshida, Motoaki [1 ]
Hayashi, Hideyuki [2 ]
机构
[1] Fukuoka Univ, Hayashi Eye Hosp, Hakata Ku, Fukuoka 812, Japan
[2] Fukuoka Univ, Dept Ophthalmol, Sch Med, Fukuoka 812, Japan
关键词
INTRAOCULAR-LENS IMPLANTATION; 1.4 MM INCISION; BIMANUAL PHACOEMULSIFICATION; WOUND-TEMPERATURE; MICROPHACOEMULSIFICATION; ASTIGMATISM; WHITESTAR; OUTCOMES; SYSTEM; FEASIBILITY;
D O I
10.1016/j.jcrs.2008.10.031
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
PURPOSE: To compare changes in corneal topography and in regular and irregular astigmatism after coaxial clear corneal microincision cataract surgery (MICS) and after coaxial small-incision cataract surgery (SICS). SETTING: Hayashi Eye Hospital, Fukuoka, Japan. METHODS: Induced corneal astigmatism was determined using vector analysis. The averaged corneal shape changes and degree of irregular astigmatism were examined using videokeratography preoperatively as well as 2 days and 1, 2, 4, and 8 weeks postoperatively. RESULTS: One hundred twenty eyes of 60 patients scheduled for phacoemulsification were evaluated. Sixty eyes had MICS (2.00 mm), and the 60 contralateral eyes had SICS (2.65 mm). The mean induced corneal astigmatism was significantly less in the MICS group than in the SICS group (P <=.0495) 1 week postoperatively and subsequently. The averaged difference map on videokeratography showed focal corneal flattening corresponding to the incision and coupled steepening around the flattened area 2 days postoperatively in both groups. The flattening and steepening gradually reduced to virtually the preoperative shape by 8 weeks; the changes were significantly less in the MICS group than in the SICS group. Of the irregular astigmatic components, higher-order irregularity was significantly less in the MICS group than in the SICS group up to 2 weeks postoperatively (P <=.0470). CONCLUSION: Induced astigmatism, focal wound-related flattening of the peripheral cornea, and corneal surface irregularity were signficantly less after coaxial MICS than after SICS.
引用
收藏
页码:233 / 239
页数:7
相关论文
共 37 条
[1]
Phakonit: Phacoemulsification through a 0.9 mm corneal incision [J].
Agarwal, A ;
Agarwal, A ;
Agarwal, S ;
Narang, P ;
Narang, S .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (10) :1548-1552
[2]
Outcomes of microincision cataract surgery versus coaxial phacoemulsification [J].
Alió, J ;
Rodríguez-Prats, JL ;
Galal, A ;
Ramzy, M .
OPHTHALMOLOGY, 2005, 112 (11) :1997-2003
[3]
Visual outcome of microincision cataract surgery with implantation of an Acri.Smart lens [J].
Alió, JL ;
Rodriguez-Prats, JL ;
Vianello, A ;
Galal, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (08) :1549-1556
[4]
Retinal image quality after microincision intraocular lens implantation [J].
Alió, JL ;
Schimchak, P ;
Montés-Micó, R ;
Galal, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (08) :1557-1560
[5]
Corneal wound architecture and integrity after phacoemulsification - Evaluation of coaxial, microincision coaxial, and microincision bimanual techniques [J].
Berdahl, John P. ;
DeStafeno, John J. ;
Kim, Terry .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03) :510-515
[6]
Feasibility of sleeveless bimanual phacoemulsification with the Millennium microsurgical system [J].
Braga-Mele, R ;
Liu, E .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (11) :2199-2203
[7]
Bimanual microphacoemulsification versus coaxial miniphacoemulsification: Prospective study [J].
Cavallini, Gian Maria ;
Campi, Luca ;
Masini, Cristina ;
Pelloni, Simone ;
Pupino, Alessandro .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03) :387-392
[8]
Endophthalmitis after microincision cataract surgery [J].
Chee, SP ;
Bacsal, K .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) :1834-1835
[9]
Early visual results with the rollable ThinOptX intraocular lens [J].
Dogru, M ;
Honda, R ;
Omoto, M ;
Fujishima, H ;
Yagi, Y ;
Tsubota, K .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (03) :558-565
[10]
Efficacy and wound-temperature gradient of WhiteStar phacoemulsification through a 1.2 mm incision [J].
Donnenfeld, ED ;
Olson, RJ ;
Solomon, R ;
Finger, PT ;
Biser, SA ;
Perry, HD ;
Doshi, S .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (06) :1097-1100