Dynamic MR digital subtraction angiography using contrast enhancement, fast data acquisition, and complex subtraction

被引:139
作者
Wang, Y
Johnston, DL
Breen, JF
Huston, J
Jack, CR
Julsrud, PR
Kiely, MJ
King, BF
Riederer, SL
Ehman, RL
机构
[1] Diagnostic Radiology, Mayo Clinic, Rochester, MN
[2] Cardiology, Mayo Clinic, Rochester, MN
[3] MRI Laboratory, Diagnostic Radiology, Mayo Clinic, Rochester, MN 55905, 200 First Street, SW
关键词
MR DSA; MRA; enhancement; complex subtraction;
D O I
10.1002/mrm.1910360408
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A dynamic MR angiography technique, MR digital subtraction angiography (MR DSA), is proposed using fast acquisition, contrast enhancement, and complex subtraction, When a bolus of contrast is injected into a patient, data acquisition begins, dynamically acquiring a thick slab using a fast gradient echo sequence for 10-100 s, Similar to x-ray DSA, a mask is selected from the images without contrast enhancement, and later images are subtracted from the mask to generate angiograms. Complex subtraction is used to overcome the partial volume effects related to the phase difference between the flowing and stationary magnetization in a voxel, Vessel signal is the enhancement of flow magnetization resulting from the contrast bolus, MR DSA was performed in 28 patients, including vessels in the lungs, brains, legs, abdomen, and pelvis, All targeted vessels were well depicted with MR DSA, Corresponding dynamic information (contrast arrival time t(a) and duration of the arterial phase t(av)) was measured: t(a)/t(av) = 3.4/4.7 s for the lung, 10.3/4.9 s for the brain, 12.8/19.3 for the aorta, 15.2/12.6 s for the leg, MR DSA can provide dynamic angiographic images using a very short acquisition time.
引用
收藏
页码:551 / 556
页数:6
相关论文
共 13 条
[1]   DYNAMIC CONTRAST-ENHANCED SUBTRACTION MR-ANGIOGRAPHY OF THE LOWER-EXTREMITIES - INITIAL EVALUATION WITH A MULTISECTION 2-DIMENSIONAL TIME-OF-FLIGHT SEQUENCE [J].
ADAMIS, MK ;
LI, W ;
WIELOPOLSKI, PA ;
KIM, D ;
SAX, EJ ;
KENT, KC ;
EDELMAN, RR .
RADIOLOGY, 1995, 196 (03) :689-695
[2]  
Anderson CM, 1993, CLIN MAGNETIC RESONA
[3]   PROJECTION ANGIOGRAMS OF BLOOD LABELED BY ADIABATIC FAST PASSAGE [J].
DIXON, WT ;
DU, LN ;
FAUL, DD ;
GADO, M ;
ROSSNICK, S .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (03) :454-462
[4]   FAST MR-ANGIOGRAPHY OF THE AORTOILIAC ARTERIES AND ARTERIES OF THE LOWER-EXTREMITY - VALUE OF BOLUS-ENHANCED, WHOLE-VOLUME SUBTRACTION TECHNIQUE [J].
DOUEK, PC ;
REVEL, D ;
CHAZEL, S ;
FALISE, B ;
VILLARD, J ;
AMIEL, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) :431-437
[5]   MAGNETIC-RESONANCE ANGIOGRAPHY [J].
DUMOULIN, CL ;
HART, HR .
RADIOLOGY, 1986, 161 (03) :717-720
[6]  
EDWARDS WD, 1991, CARDIOLOGY FUNDAMENT, V1, P75
[7]   CAROTID-ARTERY - PROSPECTIVE BLINDED COMPARISON OF 2-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY WITH CONVENTIONAL ANGIOGRAPHY AND DUPLEX US [J].
HUSTON, J ;
LEWIS, BD ;
WIEBERS, DO ;
MEYER, FB ;
RIEDERER, SJ ;
WEAVER, AL .
RADIOLOGY, 1993, 186 (02) :339-344
[8]  
KRUGER RA, 1984, DIGITAL SUBTRACTION
[9]   MR ANGIOGRAPHY BY SELECTIVE INVERSION RECOVERY [J].
NISHIMURA, DG ;
MACOVSKI, A ;
PAULY, JM ;
CONOLLY, SM .
MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (02) :193-202
[10]  
POTCHEN EJ, 1993, MAGNETIC RESONANCE C