Effect of degradation rates of resorbable phosphate invert glasses on in vitro osteoblast proliferation

被引:36
作者
Brauer, DS
Rüssel, C
Li, W
Habelitz, S
机构
[1] Univ Calif San Francisco, Dept Prevent & Restorat Dent Sci, San Francisco, CA 94143 USA
[2] Univ Jena, Otto Schott Inst, D-07743 Jena, Germany
[3] Univ Calif San Francisco, Dept Orofacial Sci, San Francisco, CA 94143 USA
关键词
degradable phosphate glasses; porous scaffolds; in vitro biocompatibility; hard tissue replacement; bioresorbable implant materials;
D O I
10.1002/jbm.a.30610
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Four resorbable phosphate invert glasses for use as bone replacement were synthesized in the system P2O5CaO-MgO-Na2O. TiO2 and SiO2 were added at concentrations of 1 and 5.5 mol % to control solubility and crystallization. Both bulk glasses and samples with an open porosity of 65% and pore sizes of 150 to 400 mu m were produced using a salt sintering process. Addition of TiO2 decreased the solubility in water and simulated body fluid, while the glass with addition of SiO2 showed a higher dissolution rate than did the original glass. The hypothesis that dissolution rates of the glasses will affect cell proliferation of osteoblastlike cells was tested using a MC3T3-E1.4 murine preosteoblast cell line. Cells were cultured on nonporous polished and porous glasses with tissue culture polystyrene (TCPS) as control. Cell proliferation was studied over 24 and 72 h in culture. Cells proliferated on all polished glasses, but proliferation on porous glasses showed variations with glass composition. Cell proliferation increased with decreased solubility of the glass. It is suggested that resorbable implant materials require the adjustment of dissolution rate so as to facilitate cell adhesion and proliferation and thus a gradual transition from artificial implant to new bone structure. (c) 2005 Wiley Periodicals, Inc.
引用
收藏
页码:213 / 219
页数:7
相关论文
共 29 条
[1]   Processing, characterisation and biocompatibility of iron-phosphate glass fibres for tissue engineering [J].
Ahmed, I ;
Collins, CA ;
Lewis, MP ;
Olsen, I ;
Knowles, JC .
BIOMATERIALS, 2004, 25 (16) :3223-3232
[2]   Phosphate glasses for tissue engineering:: Part 2.: Processing and characterisation of a ternary-based P2O5-CaO-Na2O glass fibre system [J].
Ahmed, I ;
Lewis, M ;
Olsen, I ;
Knowles, JC .
BIOMATERIALS, 2004, 25 (03) :501-507
[3]   Phosphate glasses for tissue engineering:: Part 1.: Processing and characterisation of a ternary-based P2O5-CaO-Na2O glass system [J].
Ahmed, I ;
Lewis, M ;
Olsen, I ;
Knowles, JC .
BIOMATERIALS, 2004, 25 (03) :491-499
[4]  
[Anonymous], 1989, 719 DIN ISO
[5]   Soluble phosphate glasses: in vitro studies using human cells of hard and soft tissue origin [J].
Bitar, M ;
Salih, V ;
Mudera, V ;
Knowles, JC ;
Lewis, MP .
BIOMATERIALS, 2004, 25 (12) :2283-2292
[6]   Growth of osteoblast-like cells on porous hydroxyapatite ceramics:: an in vitro study [J].
Cerroni, L ;
Filocamo, R ;
Fabbri, M ;
Piconi, C ;
Caropreso, S ;
Condò, SG .
BIOMOLECULAR ENGINEERING, 2002, 19 (2-6) :119-124
[7]   DEPENDENCE OF APATITE FORMATION ON SILICA-GEL ON ITS STRUCTURE - EFFECT OF HEAT-TREATMENT [J].
CHO, SB ;
NAKANISHI, K ;
KOKUBO, T ;
SOGA, N ;
OHTSUKI, C ;
NAKAMURA, T ;
KITSUGI, T ;
YAMAMURO, T .
JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1995, 78 (07) :1769-1774
[8]  
Chouteau J, 2003, REV CHIR ORTHOP, V89, P44
[9]   Analysis of the structural changes of a phosphate glass during its dissolution in simulated body fluid [J].
Clément, J ;
Manero, JM ;
Planell, JA ;
Avila, G ;
Martínez, S .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1999, 10 (12) :729-732
[10]   Current state of the art of biphasic calcium phosphate bioceramics [J].
Daculsi, G ;
Laboux, O ;
Malard, O ;
Weiss, P .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2003, 14 (03) :195-200