Sagittal laser optical tomography for imaging of rheumatoid finger joints

被引:119
作者
Hielscher, AH [1 ]
Klose, AD
Scheel, AK
Moa-Anderson, B
Backhaus, M
Netz, U
Beuthan, J
机构
[1] Columbia Univ, Dept Biomed Engn, New York, NY 10027 USA
[2] Columbia Univ, Dept Radiol, New York, NY 10027 USA
[3] Univ Gottingen, Dept Nephrol & Rheumatol, D-3400 Gottingen, Germany
[4] Charite, Dept Rheumatol & Clin Immunol, Berlin, Germany
[5] Free Univ Berlin, Inst Med Phys & Laser Med, D-1000 Berlin, Germany
关键词
D O I
10.1088/0031-9155/49/7/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We present a novel optical tomographic imaging system that was designed to determine two-dimensional spatial distribution of optical properties in a sagittal plane through finger joints. The system incorporates a single laser diode and a single silicon photodetector into a scanning device that records spatially resolved light intensities as they are transmitted through a finger. These data are input to a model-based iterative image reconstruction (MOBIIR) scheme, which uses the equation of radiative transfer (ERT) as a forward model for light propagation through tissue. We have used this system to obtain tomographic images of six proximal interphalangeal finger joints from two patients with rheumatoid arthritis. The optical images were compared to clinical symptoms and ultrasound images.
引用
收藏
页码:1147 / 1163
页数:17
相关论文
共 61 条
[51]   Interobserver agreement in ultrasonography of the finger and toe joints in rheumatoid arthritis [J].
Szkudlarek, M ;
Court-Payen, M ;
Jacobsen, S ;
Klarlund, M ;
Thomsen, HS ;
Ostergaard, M .
ARTHRITIS AND RHEUMATISM, 2003, 48 (04) :955-962
[52]   Imaging of the musculoskeletal system: magnetic resonance imaging, ultrasonography and computed tomography [J].
Tan, AL ;
Wakefield, RJ ;
Conaghan, PG ;
Emery, P ;
McGonagle, D .
BEST PRACTICE & RESEARCH IN CLINICAL RHEUMATOLOGY, 2003, 17 (03) :513-528
[53]  
TROMBERG BJ, 2000, OSA BIOM TOP M 2000
[54]  
TROMBERG BJ, 2002, OSA BIOM TOP M 2002
[55]   Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging of the brain [J].
Wang, XD ;
Pang, YJ ;
Ku, G ;
Xie, XY ;
Stoica, G ;
Wang, LHV .
NATURE BIOTECHNOLOGY, 2003, 21 (07) :803-806
[56]  
Winalski CS, 1996, RADIOL CLIN N AM, V34, P243
[57]  
Wolfe F, 2001, J RHEUMATOL, V28, P1712
[58]   Imaging of in vitro and in vivo bones and joints with continuous-wave diffuse optical tomography [J].
Xu, Y ;
Iftimia, N ;
Jiang, HB ;
Key, LL ;
Bolster, MB .
OPTICS EXPRESS, 2001, 8 (07) :447-451
[59]   Absorption and scattering images of heterogeneous scattering media can be simultaneously reconstructed by use of dc data [J].
Xu, Y ;
Gu, XJ ;
Khan, T ;
Jiang, HB .
APPLIED OPTICS, 2002, 41 (25) :5427-5437
[60]   Three-dimensional diffuse optical tomography of bones and joints [J].
Xu, Y ;
Iftimia, N ;
Jiang, HB ;
Key, LL ;
Bolster, MB .
JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (01) :88-92