The effects of bipolar electrode montage on conduction velocity estimation from the surface electromyogram

被引:9
作者
Beck, RBJ
O'Malley, M [1 ]
van Dijk, JP
Nolan, P
Stegeman, DF
机构
[1] Natl Univ Ireland Univ Coll Dublin, Dept Elect & Elect Engn, Dublin 4, Ireland
[2] Univ Med Ctr Nijmegen, Dept Clin Neurophysiol, Inst Neurol, Nijmegen, Netherlands
[3] Interuniv Inst Fundamental & Clin Human Movement, Nijmegen, Netherlands
[4] Univ Coll Dublin, Conway Inst, Dept Human Anat & Physiol, Dublin 2, Ireland
关键词
surface EMG; electrode montage; inter-electrode distance; conduction velocity;
D O I
10.1016/j.jelekin.2003.09.024
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
This study examines the influence of the bipolar electrode montage on conduction velocity (CV) estimation. Electrode montage refers to the combination of two parameters, the inter-electrode distance (IED), the distance between the two electrodes of a bipolar pair, and the inter-signal distance (ISD), the distance between two bipolar signals used to calculate CV. Data from the biceps brachii (BB) and tibialis anterior (TA) of healthy subjects are analysed. Two approaches are used for CV estimation. The first returns a single value per epoch. The second is based on finding velocity values from individual peaks in the signal and results in a peak velocity (PV) distribution being generated per epoch. It is concluded that CV estimation is significantly dependent on the choice of the (IED, ISD) electrode montage. The main results are that the electrode montage affects (1) the mean PV and CV estimates, (typically P<0.001), (2) the degree of spatial variability, and (3) the width of the PV distributions. The combination of a small IED and large an ISD is recommended. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:505 / 514
页数:10
相关论文
共 39 条
[1]   A high-density multichannel surface electromyography system for the characterization of single motor units [J].
Blok, JH ;
van Dijk, JP ;
Drost, G ;
Zwarts, MJ ;
Stegeman, DF .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (04) :1887-1897
[2]   Three-layer volume conductor model and software package for applications in surface electromyography [J].
Blok, JH ;
Stegeman, DF ;
van Oosterom, A .
ANNALS OF BIOMEDICAL ENGINEERING, 2002, 30 (04) :566-577
[3]   MYOELECTRIC SIGNAL CONDUCTION-VELOCITY AND SPECTRAL PARAMETERS - INFLUENCE OF FORCE AND TIME [J].
BROMAN, H ;
BILOTTO, G ;
DE LUCA, CJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 58 (05) :1428-1437
[4]   PHYSIOLOGY AND MATHEMATICS OF MYOELECTRIC SIGNALS [J].
DE LUCA, CJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1979, 26 (06) :313-325
[5]   Neither high-pass filtering nor mathematical differentiation of the EMG signals can considerably reduce cross-talk [J].
Dimitrova, NA ;
Dimitrov, GV ;
Nikitin, OA .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2002, 12 (04) :235-246
[6]   Comparison of algorithms for estimation of EMG variables during voluntary isometric contractions [J].
Farina, D ;
Merletti, R .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2000, 10 (05) :337-349
[7]   Influence of anatomical, physical, and detection-system parameters on surface EMG [J].
Farina, D ;
Cescon, C ;
Merletti, R .
BIOLOGICAL CYBERNETICS, 2002, 86 (06) :445-456
[8]   Estimation of single motor unit conduction velocity from surface electromyogram signals detected with linear electrode arrays [J].
Farina, D ;
Muhammad, W ;
Fortunato, E ;
Meste, O ;
Merletti, R ;
Rix, H .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2001, 39 (02) :225-236
[9]   DETECTION OF MOTOR UNIT ACTION-POTENTIALS WITH SURFACE ELECTRODES - INFLUENCE OF ELECTRODE SIZE AND SPACING [J].
FUGLEVAND, AJ ;
WINTER, DA ;
PATLA, AE ;
STASHUK, D .
BIOLOGICAL CYBERNETICS, 1992, 67 (02) :143-153
[10]   DEPENDENCE OF THE MEAN POWER FREQUENCY OF THE ELECTROMYOGRAM ON MUSCLE FORCE AND FIBER TYPE [J].
GERDLE, B ;
HENRIKSSONLARSEN, K ;
LORENTZON, R ;
WRETLING, ML .
ACTA PHYSIOLOGICA SCANDINAVICA, 1991, 142 (04) :457-465