Modeling and fabrication of capillary stop valves for planar microfluidic systems

被引:81
作者
Gliere, Alain [1 ]
Delattre, Cyril [1 ]
机构
[1] CEA Rech Technol, LETI, F-38054 Grenoble, France
关键词
capillary stop valves; modeling; finite element method; deep reactive ion etching; microfluidics;
D O I
10.1016/j.sna.2005.12.011
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work reports numerical and experimental investigations of capillary stop valves, which simply rely on the sudden expansion of a microchannel to control the liquid position. The simulation approach is based on the solution of the free surface equilibrium problem by the Finite Element Method. In contrast to analytical solutions, it deals rigorously with the complex geometries found in planar microfluidic systems. In contrast to energy minimization approach, it leaves the way open to the future introduction of dynamic effects. Microfluidic systems, including a new design of capillary stop valves expanding along both channel width and depth, have been fabricated by a two-level Deep Reactive Ion Etching technology, The silicon substrate is limited by a bonded PolyDimethlylSiloxane (PDMS) cover. The microvalves with cross-section dimensions down to 15 mu m x 15 mu m, which are able to stop biological buffers and burst at pressures in the 1-10 kPa range, are suitable for Lab-on-a-Chip applications. The computed burst pressure agrees well with the measurements when the liquid is water. However, when liquids containing surfactants are used a deviation is ascertained. It may be explained by the transient variation of surface tension due to the dynamics of meniscus expansion. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:601 / 608
页数:8
相关论文
共 18 条
[1]   Microfabricated cross-flow chemical reactor for catalyst testing [J].
Ajmera, SK ;
Delattre, C ;
Schmidt, MA ;
Jensen, KF .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 82 (2-3) :297-306
[2]   Hydrophobic valves of plasma deposited octafluorocyclobutane in DRIE channels [J].
Andersson, H ;
van der Wijngaart, W ;
Griss, P ;
Niklaus, F ;
Stemme, G .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 75 (1-2) :136-141
[3]   Characterization of a time multiplexed inductively coupled plasma etcher [J].
Ayón, AA ;
Braff, R ;
Lin, CC ;
Sawin, HH ;
Schmidt, MA .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1999, 146 (01) :339-349
[4]  
BHARDWAJ J, 1997, S MICR MICR SYST ANN
[5]  
Brakke K., 1992, EXP MATH, V1, P141, DOI DOI 10.1080/10586458.1992.10504253
[6]  
CHO H, 2004, P 2004 NAN C TRAD SH
[7]   Adsorption relaxation for nonionic surfactants under mixed barrier-diffusion and micellization-diffusion control [J].
Danov, KD ;
Valkovska, DS ;
Kralchevsky, PA .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2002, 251 (01) :18-25
[8]   Microfabricated centrifugal microfluidic systems: Characterization and multiple enzymatic assays [J].
Duffy, DC ;
Gillis, HL ;
Lin, J ;
Sheppard, NF ;
Kellogg, GJ .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4669-4678
[9]  
EGIDI G, 2003, 12 INT C SOL STAT AC
[10]   Pressure barrier of capillary stop valves in micro sample separators [J].
Leu, TS ;
Chang, PY .
SENSORS AND ACTUATORS A-PHYSICAL, 2004, 115 (2-3) :508-515