Rapid determination of three anticoagulant rodenticides in whole blood by liquid chromatography coupled with electrospray ionization mass spectrometry

被引:32
作者
Jin, Mi-cong [1 ]
Chen, Xiao-hong [1 ]
机构
[1] Ningbo Municipal Ctr Dis Control & Prevent, Ningbo 315010, Peoples R China
关键词
D O I
10.1002/rcm.2654
中图分类号
Q5 [生物化学];
学科分类号
071010 [生物化学与分子生物学]; 081704 [应用化学];
摘要
A rapid, sensitive and selective method for the simultaneous determination of bromadiolone, flocoumafen and brodifacoum in whole blood using warfarin as internal standard (IS) by high-performance liquid chromatography coupled with electrospray ionization mass spectrometry (HPLC/ ESI-MS) has been developed and validated. The target compounds were extracted from the whole blood with ethyl acetate and separated on an XDB C-18 column (150 mm X 2.1 mm i.d. X 5 mu m) by using a mobile phase consisting of 0.2% acetic acid/methanol (12/88, v/v) at a constant flow rate of 0.50 mL/min. The analytes were detected using negative ESI-MS in the selected ion monitoring (SIM) mode. The molecular ions [M-H](-) of m/z 527, 541,523 and 307 were selected for the quantification for bromadiolone, flocoumafen, brodifacoum and the IS, respectively. The calibration curves were linear (r(2) > 0.995) in the concentration range of 0.50-100.00 ng/mL. The method showed a satisfactory sensitivity (0.05-0.5 ng/mL using 200 mu L blood), precision (RSD < 11.9%), accuracy (recovery: 82.0-96.1%) and selectivity. This method was successfully applied to the determination of the analytes for the diagnoses of poisoned human beings and animals. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:2741 / 2746
页数:6
相关论文
共 16 条
[1]
Development of a liquid chromatography/tandem mass spectrometry method for the simultaneous determination of 16 mycotoxins on cellulose filters and in fungal cultures [J].
Delmulle, B ;
De Saeger, S ;
Adams, A ;
De Kimpe, N ;
Van Peteghem, C .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (05) :771-776
[2]
Reversed-phase HPLC determination of eight anticoagulant rodenticides in animal liver [J].
Fauconnet, V ;
Pouliquen, H ;
Pinault, L .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1997, 21 (07) :548-553
[3]
A method for simultaneous determination of five anticoagulant rodenticides in whole blood by high-performance liquid chromatography [J].
Guan, F ;
Ishii, A ;
Seno, H ;
Watanabe, K ;
Kumazawa, T ;
Suzuki, O .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 21 (01) :179-185
[4]
Use of an ion-pairing reagent for high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry determination of anionic anticoagulant rodenticides in body fluids [J].
Guan, FY ;
Ishii, A ;
Seno, H ;
Watanabe-Suzuki, K ;
Kumazawa, T ;
Suzuki, O .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 731 (01) :155-165
[5]
GUAN FY, 1995, ANAL CHEM, V23, P159
[6]
Simultaneous determination of 19 chlorophenols in water by liquid chromatography-mass spectrometry with solid-phase extraction [J].
Jin, Micong ;
Chen, Xiaohong ;
Pan, Bingxian .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2006, 29 (09) :1369-1380
[7]
A METHOD FOR THE SIMULTANEOUS IDENTIFICATION AND QUANTITATION OF 5 SUPERWARFARIN RODENTICIDES IN HUMAN SERUM [J].
KUIJPERS, EAP ;
DENHARTIGH, J ;
SAVELKOUL, TJF ;
DEWOLFF, FA .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1995, 19 (07) :557-562
[8]
Progress of liquid chromatography-mass spectrometry in clinical and forensic toxicology [J].
Marquet, P .
THERAPEUTIC DRUG MONITORING, 2002, 24 (02) :255-276
[9]
Matrix effect in quantitative LC/MS/MS analyses of biological fluids: A method for determination of finasteride in human plasma at picogram per milliliter concentrations [J].
Matuszewski, BK ;
Constanzer, ML ;
Chavez-Eng, CM .
ANALYTICAL CHEMISTRY, 1998, 70 (05) :882-889
[10]
PAULA RR, 2000, J PHARM BIOMED ANAL, V22, P573