Reversed-phase HPLC determination of eight anticoagulant rodenticides in animal liver

被引:39
作者
Fauconnet, V [1 ]
Pouliquen, H [1 ]
Pinault, L [1 ]
机构
[1] ECOLE NATL VET,LAB PHARM & TOXICOL,F-44307 NANTES 03,FRANCE
关键词
D O I
10.1093/jat/21.7.548
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A reversed-phase high-performance liquid chromatographic method was developed for the analysis of eight anticoagulant rodenticides in animal liver. Coumarinic anticoagulant rodenticides (brodifacoum, bromadiolone, coumachlor, coumatetralyl, difenacoum, and warfarin) were detected by using a gradient elution and a fluorimetric detection. Indanedione anticoagulant rodenticides (chlorophacinone and diphacinone) were detected by using an isocratic elution and an UV detection. Anticoagulants were extracted from liver with mixtures of acetone/diethylether and acetone/chloroform. Extracts were applied to solid-phase extraction cartridges. Linearity was checked over the concentration range 0.1-0.6 μg/g. Relative standard deviations of within-run and between-run variability were all between 5.7 and 10.3%. Recoveries from spiked liver samples were between 51.7 (difenacoum) and 78.2% (warfarin). Limits of detection were between 0.01 (difenacoum and warfarin) and 0.11 μg/g (chlorophacinone).
引用
收藏
页码:548 / 553
页数:6
相关论文
共 21 条
[1]  
ADDISON JB, 1982, J ASSOC OFF ANA CHEM, V65, P1299
[2]  
[Anonymous], STP PHARM PRATIQUES
[3]   ANTICOAGULANT POISONING IN ANIMALS - A SIMPLE NEW HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHIC (HPTLC) METHOD FOR THE SIMULTANEOUS DETERMINATION OF 8 ANTICOAGULANT RODENTICIDES IN LIVER SAMPLES [J].
BERNY, PJ ;
BURONFOSSE, T ;
LORGUE, G .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1995, 19 (07) :576-580
[4]   SIMULTANEOUS DETERMINATION OF 8 ANTICOAGULANT RODENTICIDES IN BLOOD-SERUM AND LIVER [J].
CHALERMCHAIKIT, T ;
FELICE, LJ ;
MURPHY, MJ .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1993, 17 (01) :56-61
[5]   THE DETERMINATION OF THE ANTICOAGULANT RODENTICIDE BRODIFACOUM IN BLOOD-SERUM BY LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
FELICE, LJ ;
MURPHY, MJ .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1989, 13 (04) :229-231
[6]   IMPROVED HPLC METHOD FOR DETERMINING BRODIFACOUM IN ANIMAL-TISSUES [J].
HOOGENBOOM, JJL ;
RAMMELL, CG .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1983, 31 (02) :239-243
[7]   REVERSED-PHASE ION-PAIR LIQUID-CHROMATOGRAPHIC DETERMINATION OF CHLOROPHACINONE RESIDUES IN ANIMAL-TISSUES [J].
HUNTER, K .
JOURNAL OF CHROMATOGRAPHY, 1984, 299 (02) :405-414
[8]   DETERMINATION OF COUMARIN ANTICOAGULANT RODENTICIDE RESIDUES IN ANIMAL TISSUE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. FLUORESCENCE DETECTION USING POST-COLUMN TECHNIQUES [J].
HUNTER, K .
JOURNAL OF CHROMATOGRAPHY, 1983, 270 (NOV) :267-276
[9]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC STRATEGIES FOR THE DETERMINATION AND CONFIRMATION OF ANTICOAGULANT RODENTICIDE RESIDUES IN ANIMAL-TISSUES [J].
HUNTER, K .
JOURNAL OF CHROMATOGRAPHY, 1985, 321 (02) :255-272
[10]   HPLC determination of anticoagulant rodenticide residues in animal livers [J].
Jones, A .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1996, 56 (01) :8-15