MR angiographic evaluation of complications in surgically treated type A aortic dissection

被引:22
作者
Garcia, Angela [1 ]
Ferreiros, Joaquin [1 ]
Santamaria, Monica [1 ]
Bustos, Ana [1 ]
Abades, Jose Luis [1 ]
Santamaria, Nuria [1 ]
机构
[1] Univ Complutense, Hosp Clin San Carlos, Dept Diagnost Imaging, E-28040 Madrid, Spain
关键词
D O I
10.1148/rg.264055082
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Thoracic aortic dissection is a life-threatening disease with a high mortality rate and an elevated incidence of early and long-term complications. Advances in surgical treatment of ascending (Stanford type A) aortic dissection have helped improve patient survival, but follow-up imaging is critically important for the identification of postsurgical complications. Gadolinium-enhanced three-dimensional (3D) magnetic resonance (MR) angiography, along with multisection computed tomography, is the technique of choice for this purpose. For accurate assessment of 3D MR angiograms, it is important to know what surgical procedure was performed and to be familiar with the appearance of the normal postsurgical anatomy. A thorough understanding of potential postsurgical complications also is essential. Some complications (eg, formation of a periprosthetic hematoma or pseudoaneurysm, stenosis in a graft anastomosis) may derive from the prosthesis. Complications also may occur in the remnant of the native aorta, where persistent dissection distal to the prosthesis is common and may result in false channel thrombosis or aneurysmatic dilatation with collapse of the true lumen. Residual dissection that involves the supra-aortic trunks or the visceral aortic branches may produce neurologic effects or renal and mesenteric ischemia, respectively. (C) RSNA, 2006.
引用
收藏
页码:981 / 992
页数:12
相关论文
共 21 条
[1]
A TECHNIQUE FOR COMPLETE REPLACEMENT OF ASCENDING AORTA [J].
BENTALL, H ;
DEBONO, A .
THORAX, 1968, 23 (04) :338-&
[2]
EXTENSIVE AORTIC REPLACEMENT USING ELEPHANT TRUNK PROSTHESIS [J].
BORST, HG ;
WALTERBUSCH, G ;
SCHAPS, D .
THORACIC AND CARDIOVASCULAR SURGEON, 1983, 31 (01) :37-40
[3]
CABROL C, 1986, J THORAC CARDIOV SUR, V91, P17
[4]
True-lumen collapse in aortic dissection - Part I. Evaluation of causative factors in phantoms with pulsatile flow [J].
Chung, JW ;
Elkins, C ;
Sakai, T ;
Kato, N ;
Vestring, T ;
Semba, CP ;
Slonim, SM ;
Dake, MD .
RADIOLOGY, 2000, 214 (01) :87-98
[5]
DAVID TE, 1992, J THORAC CARDIOV SUR, V103, P617
[6]
DEBAKEY ME, 1982, SURGERY, V92, P1118
[7]
Diagnosis and management of aortic dissection - Recommendations of the Task Force on Aortic Dissection, European Society of Cardiology [J].
Erbel, R ;
Alfonso, F ;
Boileau, C ;
Dirsch, O ;
Eber, B ;
Haverich, A ;
Rakowski, H ;
Struyven, J ;
Radegran, K ;
Sechtem, U ;
Taylor, J ;
Zollikofer, C ;
Klein, WW ;
Mulder, B ;
Providencia, LA .
EUROPEAN HEART JOURNAL, 2001, 22 (18) :1642-1681
[8]
POSTOPERATIVE MR FOLLOW-UP OF TYPE-A AORTIC DISSECTION [J].
FEDRIGA, E ;
GORDINI, V ;
PELLEGRINI, A ;
PAPAGNI, L .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1993, 17 (06) :873-877
[9]
TYPE-A DISSECTION OF THE THORACIC AORTA - USE OF MR-IMAGING FOR LONG-TERM FOLLOW-UP [J].
GAUBERT, JY ;
MOULIN, G ;
MESANA, T ;
CHAGNAUD, C ;
CAUS, T ;
DELANNOY, L ;
BLIN, D ;
BARTOLI, JM ;
KASBARIAN, M .
RADIOLOGY, 1995, 196 (02) :363-369
[10]
Thoracic aorta imaging with multisclice CT [J].
Gotway, MB ;
Dawn, SK .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2003, 41 (03) :521-+