Formaldehyde-releasers: relationship to formaldehyde contact allergy. Contact allergy to formaldehyde and inventory of formaldehyde-releasers

被引:139
作者
de Groot, Anton C. [1 ]
Flyvholm, Mari-ann [2 ]
Lensen, Gerda [1 ]
Menne, Torkil [3 ]
Coenraads, Pieter-Jan [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Dermatol, NL-9700 RB Groningen, Netherlands
[2] Natl Res Ctr Working Environm, DK-2100 Copenhagen, Denmark
[3] Gentofte Univ Hosp, Dermatoallergol Dept K, DK-2900 Hellerup, Denmark
关键词
contact allergy; formaldehyde; formaldehyde releaser; patch testing; review article; threshold; EUROPEAN STANDARD SERIES; PATCH TEST REACTIONS; DERMATITIS GROUP; PRESERVATIVES; SENSITIZATION; MULTICENTER; SENSITIVITY; EXPOSURE; TRENDS; HPLC;
D O I
10.1111/j.1600-0536.2009.01582.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
This is one of series of review articles on formaldehyde and formaldehyde-releasers (others: formaldehyde in cosmetics, in clothes and in metalworking fluids and miscellaneous). Thirty-five chemicals were identified as being formaldehyde-releasers. Although a further seven are listed in the literature as formaldehyde-releasers, data are inadequate to consider them as such beyond doubt. Several (nomenclature) mistakes and outdated information are discussed. Formaldehyde and formaldehyde allergy are reviewed: applications, exposure scenarios, legislation, patch testing problems, frequency of sensitization, relevance of positive patch test reactions, clinical pattern of allergic contact dermatitis from formaldehyde, prognosis, threshold for elicitation of allergic contact dermatitis, analytical tests to determine formaldehyde in products and frequency of exposure to formaldehyde and releasers. The frequency of contact allergy to formaldehyde is consistently higher in the USA (8-9%) than in Europe (2-3%). Patch testing with formaldehyde is problematic; the currently used 1% solution may result in both false-positive and false-negative (up to 40%) reactions. Determining the relevance of patch test reactions is often challenging. What concentration of formaldehyde is safe for sensitive patients remains unknown. Levels of 200-300 p.p.m. free formaldehyde in cosmetic products have been shown to induce dermatitis from short-term use on normal skin.
引用
收藏
页码:63 / 85
页数:23
相关论文
共 110 条
[51]   Antimicrobials: preservatives, antiseptics and disinfectants [J].
Goossens, A ;
Claes, L ;
Drieghe, J ;
Put, E .
CONTACT DERMATITIS, 1998, 39 (03) :133-134
[52]  
Gruvberger B, 1998, ACTA DERM-VENEREOL, V78, P52
[53]  
GRUVBERGER B, 2006, CONTACT DERMATITIS, P413
[54]   A COMPARATIVE-STUDY OF FORMALDEHYDE DETECTION USING CHROMOTROPIC-ACID, ACETYLACETONE AND HPLC IN COSMETICS AND HOUSEHOLD CLEANING PRODUCTS [J].
GRYLLAKIBERGER, M ;
MUGNY, C ;
PERRENOUD, D ;
PANNATIER, A ;
FRENK, E .
CONTACT DERMATITIS, 1992, 26 (03) :149-154
[55]  
HAMANN K, 1980, CONTACT DERMATITIS, V6, P446
[56]   Patch test reactions to cosmetic allergens in 1995-1997 and 2000-2002 in Finland - a multicentre study [J].
Hasan, T ;
Rantanen, T ;
Alanko, K ;
Harvima, RJ ;
Jolanki, R ;
Kalimo, K ;
Lahti, A ;
Lammintausta, K ;
Lauerma, AI ;
Laukkanen, A ;
Luukkaala, T ;
Riekki, R ;
Turjanmaa, K ;
Varjonen, E ;
Vuorela, AM .
CONTACT DERMATITIS, 2005, 53 (01) :40-45
[57]   Analysis of allergens in metalworking fluids [J].
Henriks-Eckerman, Maj-Len ;
Suuronen, Katri ;
Jolanki, Riitta .
CONTACT DERMATITIS, 2008, 59 (05) :261-267
[58]   Formaldehyde and formaldehyde releasers: How much avoidance of cross-reacting agents is required? [J].
Herbert, C ;
Rietschel, RL .
CONTACT DERMATITIS, 2004, 50 (06) :371-373
[59]   RESULTS OF ROUTINE PATCH TESTING OF 542 PATIENTS IN SASKATOON, CANADA [J].
HOGAN, DJ ;
HILL, M ;
LANE, PR .
CONTACT DERMATITIS, 1988, 19 (02) :120-124
[60]  
Horsfall FL, 1934, J IMMUNOL, V27, P569