Flow electrochemical determination of ascorbic acid in real samples using a glassy carbon electrode modified with a cellulose acetate film bearing 2,6-dichlorophenolindophenol

被引:82
作者
Florou, AB [1 ]
Prodromidis, MI [1 ]
Karayannis, MI [1 ]
Tzouwara-Karayanni, SM [1 ]
机构
[1] Univ Ioannina, Dept Chem, GR-45110 Ioannina, Greece
关键词
electrochemical determination of ascorbic acid; controlled porosity cellulose acetate film; beverages; pharmaceuticals; flow injection analysis; 2,6-dichlorophenolindophenol;
D O I
10.1016/S0003-2670(00)00709-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ascorbate sensor based on a glassy carbon electrode modified with a cellulose acetate polymeric film bearing 2,6-dichlorophenolindophenol (CA/DCPI-CME) was constructed. The overall reaction obeys a catalytic regeneration mechanism (EC mechanism) and the electrochemical rate constant kf for the electrocatalytic oxidation of ascorbic acid was evaluated. The modified electrodes were mounted in a flow injection (FI) manifold, poised at +100 mV versus Ag/AgCl/3 M KCl at pH 6.5 and utilized for the determination of ascorbic acid in beverages and pharmaceuticals. Good correlation with a reference method was attained. Interferents of various molecular sizes were tested. Calibration graphs were linear over the range 0.02-1 and 0.1-6 mM ascorbic acid for CA/DCPI sensors hydrolyzed in KOH and ZnCl2 solution, respectively. The throughput was 25 samples per hour and the CV was for a 0.4 mM ascorbic acid solution 0.75 (n=14) and 1.2% (n=10) for CA/DCPI sensors hydrolyzed in KOH and ZnCl2 solution, respectively. The recovery was 92-110%. The sensors showed very good repeatability and operational stability. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:113 / 121
页数:9
相关论文
共 29 条
  • [11] COMPARATIVE KINETIC STUDY FOR RATE CONSTANT DETERMINATION OF REACTION OF ASCORBIC-ACID WITH 2,6-DICHLOROPHENOLINDOPHENOL
    KARAYANNIS, MI
    [J]. TALANTA, 1976, 23 (01) : 27 - 30
  • [12] Kissinger P. T., 1996, LAB TECHNIQUES ELECT
  • [13] KISSINGER PT, 1987, FOOD TECHNOL-CHICAGO, V41, P108
  • [14] KISSINGER PT, 1996, LAB TECHNIQUES ELECT, pCH3
  • [15] ELECTROCATALYTIC OXIDATION OF ASCORBIC-ACID AT CHEMICALLY MODIFIED ELECTRODES
    KULYS, J
    DRUNGILIENE, A
    [J]. ELECTROANALYSIS, 1991, 3 (03) : 209 - 214
  • [16] PRINTED ELECTROCHEMICAL SENSOR FOR ASCORBIC-ACID DETERMINATION
    KULYS, J
    DCOSTA, EJ
    [J]. ANALYTICA CHIMICA ACTA, 1991, 243 (02) : 173 - 178
  • [17] ELECTROCATALYSIS WITH FERROCYANIDE ELECTROSTATICALLY TRAPPED IN AN ALKYLAMINESILOXANE POLYMER FILM ON A PT ELECTRODE
    KUO, KN
    MURRAY, RW
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1982, 131 (JAN) : 37 - 60
  • [18] Use of surfactant-modified cellulose acetate for a high-linearity and pH-resistant glucose electrode
    Maines, A
    Cambiaso, A
    Delfino, L
    Verreschi, G
    Christie, I
    Vadgama, P
    [J]. ANALYTICAL COMMUNICATIONS, 1996, 33 (01): : 27 - 30
  • [19] MURRAY RW, 1984, ELECTROANAL CHEM, V13, P191
  • [20] ONEILL RD, 1994, ANALYST, V119, P764