Potentiometric anion selectivity of polymer-membrane electrodes based on cobalt, chromium, and aluminum salens

被引:18
作者
Badr, Ibrahim H. A. [1 ]
机构
[1] Ain Shams Univ, Fac Sci, Dept Chem, Cairo, Egypt
关键词
anion sensors; polymer-membrane electrodes; salen complexes; response mechanism;
D O I
10.1016/j.aca.2006.04.021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Metallo-salens of cobalt(II) (Co-Sal), chromium(III) (Cr-Sal), and aluminum(III) (AI-Sal) are used as the active ionophores within plasticized poly(vinyl chloride) membranes. It is shown that central metal-ion plays a critical role in directing the ionophore selectivity. Polymer-membrane electrodes based on Co-Sal, Cr-Sal, and Al-Sal are demonstrated to exhibit enhanced responses and selectivity toward nitrite/thiocyanate, thiocyanate, and fluoride anions, respectively. The improved anion selectivity of the three ionophore systems is shown to deviate significantly from the classical Hofmeister pattern that is based only on ion lipophilicity. For example, optimized membrane electrodes for nitrite ion based on Co-Sal exhibit log K-Nitrite,Anion(pot) values of -5.22, -4.66, -4.48, -2.5 towards bromide, perchlorate, nitrate, and iodide anions, respectively. Optimized membrane electrodes based on Co-Sal and Cr-Sal show near-Nernstian responses towards nitrite (-57.9 +/- 0.9 mV/decade) and thiocyanate (-56.9 +/- 0.8 mV/decade), respectively, with fast response and recovery times. In contrast, Al-Sal based membrane electrodes respond to fluoride ion in a super-Nernstian (-70 +/- 3 mV/decade) and nearly an irreversible mode. The operative response mechanism of Co-Sal, Cr-Sal, and M-Sal membrane electrodes is examined using the effect of added ionic sites on the potentiometric response characteristics. It is demonstrated that addition of lipophilic anionic sites to membrane electrodes based on the utilized metallo-salens enhances the selectivity towards the primary ion, while addition of cationic sites resulted in Hofmeister selectivity patterns suggesting that the operative response mechanism is of the charged carrier type. Electron spin resonance (ESR) data indicates that Co(II) metal-ion center of Co-Sal ionophore undergoes oxidation to Co(III). This process leads to formation of a charged anion-carrier that is consistent with the response behavior obtained for Co-Sal based membrane electrodes. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:176 / 185
页数:10
相关论文
共 65 条
[1]   Cationic or anionic sites?: Selectivity optimization of ion-selective electrodes based on charged ionophores [J].
Amemiya, S ;
Bühlmann, P ;
Pretsch, E ;
Rusterholz, B ;
Umezawa, Y .
ANALYTICAL CHEMISTRY, 2000, 72 (07) :1618-1631
[2]   Hydrogen bond based recognition of nucleotides by neutral-carrier ion-selective electrodes [J].
Amemiya, S ;
Buhlmann, P ;
Tohda, K ;
Umezawa, Y .
ANALYTICA CHIMICA ACTA, 1997, 341 (2-3) :129-139
[3]   Mercuracarborand "anti-crown ether"-based chloride sensitive liquid/polymeric membrane electrodes [J].
Badr, IHA ;
Diaz, M ;
Hawthorne, MF ;
Bachas, LG .
ANALYTICAL CHEMISTRY, 1999, 71 (07) :1371-1377
[4]   Highly selective single-use fluoride ion optical sensor based on aluminum(III)-salen complex in thin polymeric film [J].
Badr, IHA ;
Meyerhoff, ME .
ANALYTICA CHIMICA ACTA, 2005, 553 (1-2) :169-176
[5]   Highly selective optical fluoride ion sensor with submicromolar detection limit based on aluminum(III) octaethylporphyrin in thin polymeric film [J].
Badr, IHA ;
Meyerhoff, ME .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (15) :5318-5319
[6]   POTENTIOMETRIC ANION SELECTIVITY OF POLYMER MEMBRANES DOPED WITH PALLADIUM ORGANOPHOSPHINE COMPLEX [J].
BADR, IHA ;
MEYERHOFF, ME ;
HASSAN, SSM .
ANALYTICAL CHEMISTRY, 1995, 67 (15) :2613-2618
[7]   Metalloporphyrin-based polymer membrane electrode with high selectivity for 2-hydroxybenzhydroxamate [J].
Badr, IHA ;
Meyerhoff, ME ;
Hassan, SSM .
ANALYTICA CHIMICA ACTA, 1996, 321 (01) :11-19
[8]   ANION-SELECTIVE MEMBRANE ELECTRODES BASED ON METALLOPORPHYRINS - THE INFLUENCE OF LIPOPHILIC ANIONIC AND CATIONIC SITES ON POTENTIOMETRIC SELECTIVITY [J].
BAKKER, E ;
MALINOWSKA, E ;
SCHILLER, RD ;
MEYERHOFF, ME .
TALANTA, 1994, 41 (06) :881-890
[9]   Selectivity of potentiometric ion sensors [J].
Bakker, E ;
Pretsch, E ;
Bühlmann, P .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1127-1133
[10]  
Berezin B.D., 1981, COORDINATION COMPOUN