Immobilisation and evaluation of a vancomycin chiral stationary phase for capillary electrochromatography

被引:97
作者
Wikström, H [1 ]
Svensson, LA [1 ]
Torstensson, A [1 ]
Owens, PK [1 ]
机构
[1] AstraZeneca R&D Molndal, Analyt Chem Pharmceut Res & Dev, S-43183 Molndal, Sweden
关键词
capillary electrochromatography; chiral stationary phases; LC; electrochromatography; experimental design; diols; vancomycin;
D O I
10.1016/S0021-9673(99)00874-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The macrocyclic antibiotic, vancomycin, is covalently bonded to LiChrospher(R) diol silica packed columns and evaluated in capillary electrochromatography (CEC) both in the reversed-phase and polar organic mode. Initially, capillaries were packed with 5 mu m LiChrospher(R) 100 Angstrom diol silica and evaluated in CEC with a reversed-phase biphenyl-pyrene achiral test resulting in resolution and efficiency values of ca. 2.5 and 100 000 plates meter(-1), respectively. Repeatability for this test (resolution and efficiency) was also examined and found to be acceptable for both run-to-run (n=5, 0.74% and 1.5%) and column-to-column (n=5, 3.4% and 9.0%), respectively. Similar results were obtained when the 10 mu m LiChrospher(R) 1000 Angstrom diol silica was examined with the exception of efficiency, where a reduced plate height value of four times lower was obtained compared to the 100 Angstrom material. A simple three step in-situ vancomycin immobilisation procedure was subsequently carried out on these packed diol columns. Selectivity was obtained for thalidomide enantiomers on this vancomycin chiral stationary phase in reversed-phase CEC with resolution and efficiency values of ca. 2.5 and 80 000 plates meter(-1), with acceptable repeatability (n=8) 0.9% and 3.0%, respectively. Selectivity was also obtained for thalidomide enantiomers on this phase in the polar organic mode with resolution and efficiency values of ca. 2.5 and 120 000 plates meter(-1), with acceptable repeatability (n=7) 0.9% and 2.0%, respectively. It was possible to deduce from a chemometric design carried out for evaluating the mobile phase component effects that organic modifier ratio, MeOH/MeCN, played a significant role in controlling both resolution and efficiency. It was also possible to separate a number of basic analytes including four beta-adrenergic blocking agents in the polar organic mode albeit with lower resolution and efficiency values, ca. 1.5 and 45 000 plates meter(-1), respectively. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:395 / 409
页数:15
相关论文
共 50 条
[1]   A review of the current status of capillary electrochromatography technology and applications [J].
Altria, KD ;
Smith, NW ;
Turnbull, CH .
CHROMATOGRAPHIA, 1997, 46 (11-12) :664-674
[2]   MACROCYCLIC ANTIBIOTICS AS A NEW CLASS OF CHIRAL SELECTORS FOR LIQUID-CHROMATOGRAPHY [J].
ARMSTRONG, DW ;
TANG, YB ;
CHEN, SS ;
ZHOU, YW ;
BAGWILL, C ;
CHEN, JR .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :1473-1484
[3]   COVALENTLY BONDED TEICOPLANIN CHIRAL STATIONARY-PHASE FOR HPLC ENANTIOSEPARATIONS [J].
ARMSTRONG, DW ;
LIU, YB ;
EKBORGOTT, KH .
CHIRALITY, 1995, 7 (06) :474-497
[4]   EVALUATION OF THE PARAMETERS DETERMINING THE PERFORMANCE OF ELECTROCHROMATOGRAPHY IN PACKED CAPILLARY COLUMNS [J].
BEHNKE, B ;
GROM, E ;
BAYER, E .
JOURNAL OF CHROMATOGRAPHY A, 1995, 716 (1-2) :207-213
[5]   CAPILLARY ELECTROCHROMATOGRAPHY - SOME IMPORTANT CONSIDERATIONS IN THE PREPARATION OF PACKED CAPILLARIES AND THE CHOICE OF MOBILE-PHASE BUFFERS [J].
BOUGHTFLOWER, RJ ;
UNDERWOOD, T ;
PATERSON, CJ .
CHROMATOGRAPHIA, 1995, 40 (5-6) :329-335
[6]  
CARTERFINCH AS, 1999, 23 INT S HIGH PERF L
[7]  
Cikalo MG, 1998, ANALYST, V123, p87R
[8]  
CLARK BJ, 1999, 12 INT S HIGH PERF C
[9]   Capillary electrochromatography [J].
Colon, LA ;
Guo, Y ;
Fermier, A .
ANALYTICAL CHEMISTRY, 1997, 69 (15) :A461-A467
[10]   Electrochromatography [J].
Crego, AL ;
Gonzalez, A ;
Marina, ML .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1996, 26 (04) :261-304