Dosimetric comparison of stereotactic body radiotherapy using 4D CT and multiphase CT images for treatment planning of lung cancer: Evaluation of the impact on daily dose coverage

被引:49
作者
Wang, Lu [1 ]
Hayes, Shelly [1 ]
Paskalev, Kamen [1 ]
Jin, Lihui [1 ]
Buyyounouski, Mark K. [1 ]
Ma, Charlie C. -M. [1 ]
Feigenberg, Steve [1 ]
机构
[1] Fox Chase Canc Ctr, Dept Radiat Oncol, Philadelphia, PA 19111 USA
关键词
4D CT; Lung cancer; SBRT; Image-guided RT; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; INTERNAL TARGET VOLUME; RADIATION-THERAPY; TUMOR MOTION; BREATHING MOTION; GATED CT; SCANS; RESPIRATION; ARTIFACTS; 4D-CT;
D O I
10.1016/j.radonc.2008.11.018
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate the dosimetric impact of using 4D CT and multiphase (helical) CT images for treatment planning target definition and the daily target coverage in hypofractionated stereotactic body radiotherapy (SBRT) of lung cancer. Materials and methods: For 10 consecutive patients treated with SBRT, a set of 4D CT images and three sets of multiphase helical CT scans, taken during free-breathing, end-inspiration and end-expiration breath-hold, were obtained. Three separate planning target volumes (PTVs) were created from these image sets. A PTV4D was created from the maximum intensity projection (MIP) reconstructed 4D images by adding a 3 mm margin to the internal target volume (ITV). A PTV3CT was created by generating ITV from gross target volumes (GTVs) contoured from the three multiphase images. Finally, a third conventional PTV (denoted PTVconv) was created by adding 5 mm in the axial direction and 10 mm in the longitudinal direction to the GTV (in this work, GTV = CTV = clinical target volume) generated from free-breathing helical CT scans. Treatment planning was performed based on PTV4D (denoted as Plan-1), and the plan was adopted for PTV3CT and PTVconv to form Plan-2 and Plan-3, respectively, by superimposing "Plan-1" onto the helical free-breathing CT data set using modified beam apertures that conformed to either PTV3CT or PTVconv. first studied the impact of PTV design on treatment planning by evaluating the dosimetry of the three PTVs under the three plans, respectively. Then we examined the effect of the PTV designs on the daily target coverage by utilizing pre-treatment localization CT (CT-on-rails) images for daily GTV contouring and dose recalculation. The changes in the dose parameters of D-95 and D-99 (the dose received by 95% and 99% of the target volume, respectively), and the V-p (the volume receiving the prescription dose) of the daily GTVs were compared under the three plans before and after setup error correction. Results: For all 10 patients, we found that the PTV4D consistently resulted in the smallest volumes compared with the other PTV's (p = 0.005). In general, the plans generated based PTV3CT could provide reasonably good coverage for PTV4D, while the reverse can only achieve 90% of the planned values for PTV3CT. The coverage of both PTV4D and PTV3CT in Plan-3 generally reserves the original planned values in terms of D95, D99, and Vp. with the average ratios of 0.996, 0.977, and 0.977, respectively, for PTV3CT, and 1.025, 1.025, and 1.0, respectively, for PTV4D. However, it increased the dose significantly to normal lung tissue. Additionally, the plans generated using the PTV4D presented an equivalent daily target coverage compared to the plans generated using the PTV3CT (p = 0.953) and PTVconv (p = 0.773) after setup error correction. Consequently, this minimized the dose to the surrounding normal lung. Conclusion: Compared to the conventional approach using helical images for target definition, 4D CT and multiphase 3D CT have the advantage to provide patient-specific tumor motion information, based on which such designed PTVs could ensure daily target coverage. 4D CT-based treatment planning further reduces the amount of normal lung being irradiated while still providing a good target coverage when image guidance is used. (C) 2008 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 91 (2009) 314-324
引用
收藏
页码:314 / 324
页数:11
相关论文
共 42 条
[1]   Dose calculations accounting for breathing motion in stereotactic lung radiotherapy based on 4D-CT and the internal target volume [J].
Admiraal, Marjan A. ;
Schuring, Danny ;
Hurkmans, Coen W. .
RADIOTHERAPY AND ONCOLOGY, 2008, 86 (01) :55-60
[2]   A novel four-dimensional radiotherapy method for lung cancer: imaging, treatment planning and delivery [J].
Alasti, H. ;
Cho, Y. B. ;
Vandermeer, A. D. ;
Abbas, A. ;
Norrlinger, B. ;
Shubbar, S. ;
Bezjak, A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (12) :3251-3267
[3]   Comparison of helical, maximum intensity projection (MIP), and averaged intensity (Al) 4D CT imaging for stereotactic body radiation therapy (SBRT) planning in lung cancer [J].
Bradley, Jeffrey D. ;
Nofal, Ahmed N. ;
El Naqa, Issam M. ;
Lu, Wei ;
Liu, Jubei ;
Hubenschmidt, James ;
Low, Daniel A. ;
Drzymala, Robert E. ;
Khullar, Divya .
RADIOTHERAPY AND ONCOLOGY, 2006, 81 (03) :264-268
[4]   Four-dimensional Imaging and treatment planning of moving targets [J].
Chen, George T. Y. ;
Kung, Jong H. ;
Rietzel, Eike .
IMRT, IGRT, SBRT: ADVANCES IN THE TREATMENT PLANNING AND DELIVERY OF RADIOTHERAPY, 2007, 40 :59-71
[5]   Individualized planning target volumes for intrafraction motion during hypofractionated intensity-modulated radiotherapy boost for prostate cancer [J].
Cheung, P ;
Sixel, K ;
Morton, G ;
Loblaw, DA ;
Tirona, R ;
Pang, G ;
Choo, R ;
Szumacher, E ;
DeBoer, G ;
Pignol, JP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (02) :418-425
[6]   The use of gated and 4D CT imaging in planning for stereotactic body radiation therapy [J].
D'Souza, Warren D. ;
Nazareth, Daryl P. ;
Zhang, Bin ;
Deyoung, Chad ;
Suntharalingam, Mohan ;
Kwok, Young ;
Yu, Cedric X. ;
Regine, William F. .
MEDICAL DOSIMETRY, 2007, 32 (02) :92-101
[7]   Gated CT imaging using a free-breathing respiration signal from flow-volume spirometry [J].
D'Souza, WD ;
Kwok, Y ;
Deyoung, C ;
Zacharapoulos, N ;
Pepelea, M ;
Klahr, P ;
Yu, CX .
MEDICAL PHYSICS, 2005, 32 (12) :3641-3649
[8]   Tumor location cannot predict the mobility of lung tumors: A 3D analysis of data generated from multiple CT scans [J].
de Koste, JRV ;
Lagerwaard, FJ ;
Nijssen-Visser, MRJ ;
Graveland, WJ ;
Senan, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (02) :348-354
[9]   Assessment of intrafraction mediastinal and hilar lymph node movement and comparison to lung tumor motion using four-dimensional CT [J].
Donnelly, Eric D. ;
Parikh, Parag J. ;
Lu, Wei ;
Zhao, Tianyu ;
Lechleiter, Kristen ;
Nystrom, Michelle ;
Hubenschmidt, James P. ;
Low, Daniel A. ;
Bradley, Jeffrey D. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (02) :580-588
[10]   Small-volume image-guided radiotherapy using hypofractionated, coplanar, and noncoplanar multiple fields for patients with inoperable stage I nonsmall cell lung carcinomas [J].
Fukumoto, S ;
Shirato, H ;
Shimzu, S ;
Ogura, S ;
Onimaru, R ;
Kitamura, K ;
Yamazaki, K ;
Miyasaka, K ;
Nishimura, M ;
Dosaka-Akita, H .
CANCER, 2002, 95 (07) :1546-1553