Comparison of helical, maximum intensity projection (MIP), and averaged intensity (Al) 4D CT imaging for stereotactic body radiation therapy (SBRT) planning in lung cancer

被引:94
作者
Bradley, Jeffrey D. [1 ]
Nofal, Ahmed N. [1 ]
El Naqa, Issam M. [1 ]
Lu, Wei [1 ]
Liu, Jubei [1 ]
Hubenschmidt, James [1 ]
Low, Daniel A. [1 ]
Drzymala, Robert E. [1 ]
Khullar, Divya [1 ]
机构
[1] Washington Univ, Sch Med, Dept Radiat Oncol, Alvin J Siteman Canc Ctr, St Louis, MO 63110 USA
关键词
lung cancer; stereotactic body radiation therapy; helical; maximum intensity projection; 4D CT imaging;
D O I
10.1016/j.radonc.2006.10.009
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and Purpose: To compare helical, MIP and Al 4D CT imaging, for the purpose of determining the best CT-based volume definition method for encompassing the mobile gross tumor volume (mGTV) within the planning target volume (PTV) for stereotactic body radiation therapy (SBRT) in stage I lung cancer. Materials and methods: Twenty patients with medically inoperable peripheral stage 1 lung cancer were planned for SBRT. Free-breathing helical and 4D image datasets were obtained for each patient. Two composite images, the MIP and Al, were automatically generated from the 4D image datasets. The mGTV contours were delineated for the MIP, Al and helical image datasets for each patient. The volume for each was calculated and compared using analysis of variance and the Wilcoxon rank test. A spatial analysis for comparing center of mass (COM) (i.e. isocenter) coordinates for each imaging method was also performed using multivariate analysis of variance. Results: The MIP-defined mGTVs were significantly larger than both the helical- (p = 0.001) and Al-defined mGTVs (p = 0.012). A comparison of COM coordinates demonstrated no significant spatial difference in the x-, y-, and z-coordinates for each tumor as determined by helical, MIP, or Al imaging methods. Conclusions: In order to incorporate the extent of tumor motion from breathing during SBRT, MIP is superior to either helical or Al images for defining the mGTV. The spatial isocenter coordinates for each tumor were not altered significantly by the imaging methods. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:264 / 268
页数:5
相关论文
共 14 条
[1]   STEREOTAXIC HIGH-DOSE FRACTION RADIATION-THERAPY OF EXTRACRANIAL TUMORS USING AN ACCELERATOR - CLINICAL-EXPERIENCE OF THE FIRST 31 PATIENTS [J].
BLOMGREN, H ;
LAX, I ;
NASLUND, I ;
SVANSTROM, R .
ACTA ONCOLOGICA, 1995, 34 (06) :861-870
[2]   CERR: A computational environment for radiotherapy research [J].
Deasy, JO ;
Blanco, AI ;
Clark, VH .
MEDICAL PHYSICS, 2003, 30 (05) :979-985
[3]   Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking [J].
Keall, PJ ;
Joshi, S ;
Vedam, SS ;
Siebers, JV ;
Kini, VR ;
Mohan, R .
MEDICAL PHYSICS, 2005, 32 (04) :942-951
[4]   A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing [J].
Low, DA ;
Nystrom, M ;
Kalinin, E ;
Parikh, P ;
Dempsey, JF ;
Bradley, JD ;
Mutic, S ;
Wahab, SH ;
Islam, T ;
Christensen, G ;
Politte, DG ;
Whiting, BR .
MEDICAL PHYSICS, 2003, 30 (06) :1254-1263
[5]   Quantitation of the reconstruction quality of a four-dimensional computed tomography process for lung cancer patients [J].
Lu, W ;
Parikh, PJ ;
El Naqa, IM ;
Nystrom, MM ;
Hubenschmidt, JP ;
Wahab, SH ;
Mutic, S ;
Singh, AK ;
Christensen, GE ;
Bradley, JD ;
Low, DA .
MEDICAL PHYSICS, 2005, 32 (04) :890-901
[6]   Stereotactic body radiation therapy of early-stage non-small-cell lung carcinoma: Phase I study [J].
McGarry, RC ;
Papiez, L ;
Williams, M ;
Whitford, T ;
Timmerman, RD .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (04) :1010-1015
[7]   Clinical outcomes of a phase I/II study of 48 Gy of stereotactic body radiotherapy in 4 fractions for primary lung cancer using a stereotactic body frame [J].
Nagata, Y ;
Takayama, K ;
Matsuo, Y ;
Norihisa, Y ;
Mizowaki, T ;
Sakamoto, T ;
Sakamoto, M ;
Mitsumori, M ;
Shibuya, K ;
Araki, N ;
Yano, S ;
Hiraoka, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (05) :1427-1431
[8]  
Onishi H., 2003, International Journal of Radiation Oncology Biology Physics, V57, pS142, DOI 10.1016/S0360-3016(03)00853-8
[9]   Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion [J].
Rietzel, E ;
Chen, GTY ;
Choi, NC ;
Willet, CG .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (05) :1535-1550
[10]  
Song DY, 2004, ONCOLOGY-NY, V18, P1419