Retinal Nerve Fiber Layer Imaging with Spectral-Domain Optical Coherence Tomography A Variability and Diagnostic Performance Study

被引:399
作者
Leung, Christopher Kai-shun [1 ]
Cheung, Carol Yim-lui [1 ]
Weinreb, Robert N. [2 ]
Qiu, Quanliang [1 ,3 ]
Liu, Shu [1 ]
Li, Haitao [1 ]
Xu, Guihua [1 ,3 ]
Fan, Ning [1 ,4 ]
Huang, Lina [4 ]
Pang, Chi-Pui [1 ]
Lam, Dennis Shun Chiu
机构
[1] Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Hong Kong, Hong Kong, Peoples R China
[2] Univ Calif San Diego, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
[3] Shantou Univ, Coll Med, STU CUHK Joint Shantou Int Eye Ctr, Shantou, Guangdong, Peoples R China
[4] Jinan Univ, Shenzhen Eye Hosp, Shenzhen, Peoples R China
关键词
STRATUS OCT; THICKNESS; SENSITIVITY; GLAUCOMA;
D O I
10.1016/j.ophtha.2009.04.013
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
Objective: To evaluate and compare the retinal nerve fiber layer (RNFL) measurement variability, diagnostic sensitivity and specificity for glaucoma detection, and strength of the structure-function association obtained with a spectral-domain optical coherence tomography (OCT) device (Cirrus HD-OCT; Carl Zeiss Meditec, Inc., Dublin, CA) and a time-domain OCT device (Stratus OCT; Carl Zeiss Meditec, Inc.). Design: Prospective, cross-sectional study. Participants: Ninety-seven normal subjects and 83 glaucoma patients. Methods: One eye from each subject was imaged with Cirrus HD-OCT and Stratus OCT. Sixteen and 31 normal eyes were selected randomly to evaluate intravisit repeatability and intervisit reproducibility, respectively. The agreement of RNFL measurements was evaluated with Bland-Altman plots. The diagnostic sensitivity and specificity was examined with the area under the receiver operating characteristic curve (AUC). The association between average RNFL thickness and visual field sensitivity was evaluated with a second-order regression model. Main Outcome Measures: Retinal nerve fiber layer measurement variability, AUC, and coefficient of determination (R-2). Results: The intravisit repeatability of Cirrus HD-OCT ranged between 5.12 and 15.02 mu m, and the intervisit reproducibility ranged between 4.31 and 22.01 mu m. The intervisit variabilities of sectoral and average RNFL thicknesses were lower in Cirrus HD-OCT compared with Stratus OCT with significant differences at 1, 3, 4, and 8 to 11 o'clock (P <= 0.021). There were proportional biases of RNFL measurements between the 2 OCT devices. The difference of RNFL thicknesses increased with the means. The average (AUC, 0.962 for Cirrus HD-OCT and 0.956 Stratus OCT), superior (AUC, 0.963 and 0.950, respectively), and inferior (AUC, 0.949 and 0.931, respectively) RNFL thicknesses demonstrated the greatest AUCs in both OCT devices with no significant difference detected between the respective measurements (P >= 0.120). The strength of the structure-function association was comparable between Cirrus HD-OCT (R-2 = 0.580) and stratus OCT devices (R-2 = 0.623; P = 0.918). Conclusions: Although the diagnostic performance and the strength of the structure-function association were comparable between Cirrus HD-OCT and Stratus OCT RNFL measurements, Cirrus HD-OCT demonstrated lower measurement variability compared with Stratus OCT with significant differences at 1, 3, 4, and 8 to 11 o'clock. The poor agreement was likely related to the different inherent characteristics of the 2 OCT systems. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology 2009;116:1257-1263 C 2009 by the American Academy of Ophthalmology.
引用
收藏
页码:1257 / 1263
页数:7
相关论文
共 18 条
[1]
Bland JM, 1996, BRIT MED J, V313, P744
[2]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]
BLAND JM, COMP WITHIN SUBJECT
[4]
Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes [J].
Budenz, Donald L. ;
Fredette, Marie-Josee ;
Feuer, William J. ;
Anderson, Douglas R. .
OPHTHALMOLOGY, 2008, 115 (04) :661-666
[5]
Determinants of normal retinal nerve fiber layer thickness measured by stratus OCT [J].
Budenz, Donald L. ;
Anderson, Douglas R. ;
Varma, Rohit ;
Schuman, Joel ;
Cantor, Louis ;
Savell, Jonathan ;
Greenfeld, David S. ;
Patella, Vincent Michael ;
Quigley, Harry A. ;
Tielsch, James .
OPHTHALMOLOGY, 2007, 114 (06) :1046-1052
[6]
*C ZEISS MED INC, 2008, CIRR HD OCT US MAN
[7]
Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[8]
Optical coherence tomography scan circle location and mean retinal nerve fiber layer measurement variability [J].
Gabriele, Michelle L. ;
Ishikawa, Hiroshi ;
Wollstein, Gadi ;
Bilonick, Richard A. ;
Townsend, Kelly A. ;
Kagemann, Larry ;
Wojtkowski, Maciej ;
Srinivasan, Vivek J. ;
Fujimoto, James G. ;
Duker, Jay S. ;
Schuman, Joel S. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (06) :2315-2321
[9]
A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1983, 148 (03) :839-843
[10]
THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36