Do sinusoidal models of respiration accurately reflect the respiratory events of patients breathing on nebulizers?

被引:15
作者
Coates, AL [1 ]
Macneish, CF [1 ]
Allen, PD [1 ]
Ho, SL [1 ]
Lands, LC [1 ]
机构
[1] Univ Toronto, Hosp Sick Children, Div Resp Med, Toronto, ON M5G 1X8, Canada
来源
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG | 1999年 / 12卷 / 04期
关键词
pattern of breathing; nebulization; inhaled antibiotics; cystic fibrosis;
D O I
10.1089/jam.1999.12.265
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The amount of drug that is delivered by nebulization is a combination of the physical properties of the agent being nebulized, the performance of the nebulizer, and the pattern of breathing of the patient. To avoid biological variation, mechanical models of breathing are frequently employed during the evaluation of the performance of a device. For simplicity, many investigators use sinusoidal models of breathing to calculate the expected inhaled mass, although some use square waves and other more complex models. Most assume that the duration of inspiration (T-i) is half of the total respiratory time (T-tot), This study compared the calculated inhaled mass from which the expected pulmonary deposition was estimated from the actual pattern of breathing of 43 children with cystic fibrosis (CF) breathing from an unvented nebulizer with a low dead volume and appropriate particle size distribution with that from a sinusoidal pattern of breathing using the same tidal volume (VT) and respiratory rate. The respiratory duty cycle (T-i/T-tot) was 0.45 +/- 0.05, which meant that less time was spent during inspiration than that found in a pure sinusoidal pattern. The difference between the predicted deposition from the actual pattern of breathing and that calculated from the sinusoidal model was 12 +/- 7%, which correlated with the respiratory rate (r = 0.67, P < 0.001). The degree of lung disease did not influence the discrepancy between the two values. In general, the actual V(T)s and respiratory rates were less in the patients than those employed in mechanical models of pediatric breathing. Although some patients had respiratory patterns that could be represented accurately with a sinusoidal model, most did not, and there were wide variations from child to child. These results suggest that there are both systematic and random errors arising from the use of a sinusoidal waveform to mimic respiratory events in patients.
引用
收藏
页码:265 / 273
页数:9
相关论文
共 35 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   THE INFLUENCE OF AGE ON AEROSOL DEPOSITION IN CHILDREN WITH CYSTIC-FIBROSIS [J].
CHUA, HL ;
COLLIS, GG ;
NEWBURY, AM ;
CHAN, K ;
BOWER, GD ;
SLY, PD ;
LESOUEF, PN .
EUROPEAN RESPIRATORY JOURNAL, 1994, 7 (12) :2185-2191
[3]   The choice of jet nebulizer, nebulizing flow, and addition of albuterol affects the output of tobramycin aerosols [J].
Coates, AL ;
MacNeish, CF ;
Meisner, D ;
Kelemen, S ;
Thibert, R ;
MacDonald, J ;
Vadas, E .
CHEST, 1997, 111 (05) :1206-1212
[4]   A comparison of the availability of tobramycin for inhalation from vented vs unvented nebulizers [J].
Coates, AL ;
MacNeish, CF ;
Lands, LC ;
Meisner, D ;
Kelemen, S ;
Vadas, EB .
CHEST, 1998, 113 (04) :951-956
[5]  
COATES AL, UNPUB PEDIAT PULMON
[6]   AN ALTERNATE METHOD FOR THE DETERMINATION OF FUNCTIONAL RESIDUAL CAPACITY IN A PLETHYSMOGRAPH [J].
DESMOND, KJ ;
DEMIZIO, DL ;
ALLEN, PD ;
BEAUDRY, PH ;
COATES, AL .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1988, 137 (02) :273-276
[7]   Comparison of drug delivery from conventional versus "Venturi" nebulizers [J].
Devadason, SG ;
Everard, ML ;
Linto, JM ;
Le Souef, PN .
EUROPEAN RESPIRATORY JOURNAL, 1997, 10 (11) :2479-2483
[8]   DRUG DELIVERY FROM JET NEBULIZERS [J].
EVERARD, ML ;
CLARK, AR ;
MILNER, AD .
ARCHIVES OF DISEASE IN CHILDHOOD, 1992, 67 (05) :586-591
[9]  
FINDLAY JP, IN PRESS J AEROSOL M
[10]   Variations in predicted regional lung deposition of salbutamol sulphate between 19 nebulizer types [J].
Finlay, WH ;
Stapleton, KW ;
Zuberbuhler, P .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1998, 11 (02) :65-80