Improvement of stenting therapy with a silicon carbide coated tantalum stent

被引:55
作者
Amon, M
Bolz, A
Schaldach, M
机构
[1] Department of Biomedical Engineering, Friedrich-Alexander-Univ. E., D-91054 Erlangen
关键词
D O I
10.1007/BF00058566
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
State of the art cardiovascular stent materials are a compromise between bulk properties and surface related properties. As a consequence, deficiencies in both characteristics lead to serious limitations of stenting therapy. Beside a dissatisfying X-ray visibility of current stent materials, which hinders precise angiographic control of the stent during implantation, insufficient hemocompatibility causes subacute vessel occlusions despite stringent anticoagulant medication. Additionally, bleeding complications result which further limit the therapeutical success. Therefore it is essential to develop a new coronary stent with improved material properties for the bulk of the stent and its surface. This is realized by a hybrid concept. The stent is manufactured from tantalum, having a high inherent radio-opacity. The stent is coated with amorphous silicon carbide, optimized for hemocompatibility. An appropriate deposition technology to maximize coating adhesion was developed. Amorphous silicon carbide was investigated in vitro and in vivo to assess its suitability for coronary stents.
引用
收藏
页码:273 / 278
页数:6
相关论文
共 10 条
[1]  
ARAJ T, 1987, THIN SOLID FILMS, V154, P387
[2]   PHYSICAL-MECHANISMS OF SOLID-PROTEIN INTERACTIONS AT THE INTERFACE BETWEEN AMORPHOUS-SILICON CARBIDE AND FIBRINOGEN [J].
BOLZ, A ;
SCHALDACH, M .
BIOMEDIZINISCHE TECHNIK, 1992, 37 (11) :244-253
[3]  
BOLZ A, 1991, THESIS FAU ERLANGEN
[4]   CLINICAL, PHYSIOLOGICAL, ANATOMIC AND PROCEDURAL FACTORS PREDICTIVE OF RESTENOSIS AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY [J].
BOURASSA, MG ;
LESPERANCE, J ;
EASTWOOD, C ;
SCHWARTZ, L ;
COTE, G ;
KAZIM, F ;
HUDON, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (02) :368-376
[5]   FAILURE MODES IN SCRATCH ADHESION TESTING [J].
BULL, SJ .
SURFACE & COATINGS TECHNOLOGY, 1991, 50 (01) :25-32
[6]   ABRUPT CORONARY-ARTERY OCCLUSION DURING PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY [J].
DEFEYTER, PJ ;
DEJAEGERE, PPT ;
MURPHY, ES ;
SERRUYS, PW .
AMERICAN HEART JOURNAL, 1992, 123 (06) :1633-1642
[7]  
HERMANN HC, 1992, CIRCULATION, V86, P812
[8]   LONG-TERM CLINICAL AND ANGIOGRAPHIC FOLLOW-UP AFTER PLACEMENT OF PALMAZ-SCHATZ CORONARY STENT - A SINGLE-CENTER EXPERIENCE [J].
KIMURA, T ;
TAMURA, T ;
YOKOI, H ;
NOBUYOSHI, M .
JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1994, 7 (02) :129-139
[9]  
SCHATZ RA, 1993, CIRCULATION S, V88, P1
[10]  
SERRUYS PW, 1993, CIRCULATION, V88, P1