Investigation of charge collection in multi-electrode CdZnTe detectors

被引:11
作者
Prettyman, TH [1 ]
Smith, MK [1 ]
Luke, PN [1 ]
Amman, M [1 ]
Lee, J [1 ]
机构
[1] Univ Calif Los Alamos Natl Lab, Los Alamos, NM 87545 USA
来源
HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS | 1999年 / 3768卷
关键词
CdZnTe; coplanar grid; charge collection; room temperature; gamma ray; detector;
D O I
10.1117/12.366595
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Preliminary results of experiments to investigate charge collection in CdZnTe detectors are presented. The experiments support the development of semiconductor-modeling tools for device engineering that will be used to design large volume CdZnTe detectors for gamma ray spectroscopy. Improved diagnostic methods are described, including an automated alpha particle scanner for charge pulse mapping. Semiconductor modeling techniques are presented along with methods to visualize charge transport. Experimental results are compared to a physical model that has been used routinely in research on room temperature devices for gamma ray detection.
引用
收藏
页码:27 / 36
页数:10
相关论文
共 20 条
[1]   Electron transport uniformity characterization of CdZnTe using alpha particles [J].
Amman, M ;
Lee, JS ;
Luke, PN .
HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS AND APPLICATIONS, 1998, 3446 :179-190
[2]   Optimization criteria for coplanar-grid detectors [J].
Amman, M ;
Luke, PN .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :205-212
[3]   Coplanar-grid detector with single-electrode readout [J].
Amman, M ;
Luke, PN .
HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS, OPTICS, AND APPLICATIONS, 1997, 3115 :205-213
[4]   Room temperature semiconductor detectors for safeguards measurements [J].
Arlt, R ;
Rundquist, DE .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) :455-461
[6]   Charge transport and signal generation in CdTe pixel detectors [J].
Hamel, LA ;
Paquet, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) :238-240
[7]   Numerical simulation of pixellated CdZnTe detector for medical radionuclide imaging application [J].
Iwata, K ;
Hasegawa, BH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :385-391
[8]   Device simulation and optimization of laterally-contacted-unipolar-nuclear detector [J].
Lee, EY ;
James, RB .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (01) :66-71
[9]   Effect of electron transport properties on unipolar CdZnTe radiation detectors: LUND, SpectrumPlus, and coplanar grid [J].
Lee, EY ;
James, RB .
JOURNAL OF ELECTRONIC MATERIALS, 1999, 28 (06) :843-849
[10]   SINGLE-POLARITY CHARGE SENSING IN IONIZATION DETECTORS USING COPLANAR ELECTRODES [J].
LUKE, PN .