Inert metal-modified, composite ceramic-carbon, amperometric biosensors: Renewable, controlled reactive layer

被引:187
作者
Sampath, S [1 ]
Lev, O [1 ]
机构
[1] HEBREW UNIV JERUSALEM, FREDY & NADINE HERMANN SCH APPL SCI, DIV ENVIRONM SCI, IL-91904 JERUSALEM, ISRAEL
关键词
D O I
10.1021/ac951094b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new type of sol-gel-derived, inert metal-modified, composite, amperometric biosensor is developed. The electrodes are comprised of a dispersion of biochemically and chemically modified graphite powder in a porous, organically modified silicate (Ormosil) network. The percolating carbon dispersion provides electrical conductivity, oxidoreductase enzymes (e.g., glucose oxidase, lactate oxidase, or L-amino acid oxidase) are used for biocatalysis, metallic palladium is used for electrocatalysis of the biochemical reaction product, and the porous organically modified silica provides a rigid skeleton. The hydrophobicity of this composite material guarantees that only a limited section of the electrode is wetted by the aqueous analyte, thus providing a controlled-thickness reactive layer. The thickness of the reaction layer can be tuned by the addition of hydrophilic components, The electrode can be reproducibly renewed by removing its upper layer and exposing a new, thin, porous bioreactive section, The same technology is applicable for the production of thick-film, low-leaching, disposable sensors. In this configuration, the analysis is conducted using a single drop of the analyte applied on the hydrophobic film. The sensors are found to be stable over long periods.
引用
收藏
页码:2015 / 2021
页数:7
相关论文
共 41 条
  • [21] ROTATING-RING-DISK ENZYME ELECTRODE FOR BIOCATALYSIS KINETIC-STUDIES AND CHARACTERIZATION OF THE IMMOBILIZED ENZYME LAYER
    KAMIN, RA
    WILSON, GS
    [J]. ANALYTICAL CHEMISTRY, 1980, 52 (08) : 1198 - 1205
  • [22] KELLY TE, 1984, CLIN CHEM, P832
  • [23] ORGANICALLY MODIFIED SOL-GEL SENSORS
    LEV, O
    TSIONSKY, M
    RABINOVICH, L
    GLEZER, V
    SAMPATH, S
    PANKRATOV, I
    GUN, J
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (01) : A22 - A30
  • [24] LEY O, 1992, ANALUSIS, V20, P543
  • [25] GLUCOSE FAST-RESPONSE AMPEROMETRIC SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN ELECTROPOLYMERIZED POLY(ORTHO-PHENYLENEDIAMINE) FILM
    MALITESTA, C
    PALMISANO, F
    TORSI, L
    ZAMBONIN, PG
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (24) : 2735 - 2740
  • [26] GLUCOSE BIOSENSOR BASED ON A SOL-GEL-DERIVED PLATFORM
    NARANG, U
    PRASAD, PN
    BRIGHT, FV
    RAMANATHAN, K
    KUMAR, ND
    MALHOTRA, BD
    KAMALASANAN, MN
    CHANDRA, S
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (19) : 3139 - 3144
  • [27] SOL-GEL DERIVED RENEWABLE-SURFACE BIOSENSORS
    PANKRATOV, I
    LEV, O
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 393 (1-2) : 35 - 41
  • [28] APPARENT LOW SURFACE-AREAS IN MICROPOROUS SIO2-XEROGELS
    POLEVAYA, Y
    SAMUEL, J
    OTTOLENGHI, M
    AVNIR, D
    [J]. JOURNAL OF SOL-GEL SCIENCE AND TECHNOLOGY, 1995, 5 (01) : 65 - 70
  • [29] A CRITICAL-EVALUATION OF A GLUCOSE BIOSENSOR MADE BY CODEPOSITION OF PALLADIUM AND GLUCOSE-OXIDASE ON GLASSY-CARBON
    SAKSLUND, H
    WANG, J
    HAMMERICH, O
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 374 (1-2): : 71 - 79
  • [30] SURFACE-MODIFIED ELECTROCHEMICAL DETECTOR FOR LIQUID-CHROMATOGRAPHY
    SITTAMPALAM, G
    WILSON, GS
    [J]. ANALYTICAL CHEMISTRY, 1983, 55 (09) : 1608 - 1610