共 21 条
Phase-sensitive optical low-coherence reflectometry for the detection of analyte concentrations
被引:42
作者:
Larin, KV
[1
]
Akkin, T
Esenaliev, RO
Motamedi, M
Milner, TE
机构:
[1] Univ Texas, Med Branch, Lab Opt Sensing & Monitoring, Galveston, TX 77555 USA
[2] Univ Texas, Med Branch, Ctr Biomed Engn, Galveston, TX 77555 USA
[3] Univ Texas, Dept Biomed Engn, Austin, TX 78712 USA
关键词:
D O I:
10.1364/AO.43.003408
中图分类号:
O43 [光学];
学科分类号:
070207 ;
0803 ;
摘要:
Optical techniques may potentially be used for noninvasive glucose sensing. We investigated the application of phase-sensitive optical low-coherence reflectometry (PS-OLCR) to the measurement of analyte concentrations. The dependence of the PS-OLCR signal on the concentration of various analytes, including aqueous solutions of glucose, calcium chloride, magnesium chloride, sodium chloride, potassium chloride, potassium bicarbonate, urea, bovine serum albumin, and bovine globulin, were determined in clear and turbid media. Obtained results demonstrated (1) a high degree of sensitivity and accuracy of the phase measurements of analyte concentrations with PS-OLCR; (2) a concentration-dependent change in the phase-shift for glucose that is significantly greater than that of other analytes sampled over the same physiological range; and (3) a high submillimolar sensitivity of PS-OLCR for the measurement of glucose concentration. Further exploration of the application of PS-OLCR to the noninvasive, sensitive, and specific monitoring of glucose concentration seems warranted. (C) 2004 Optical Society of America.
引用
收藏
页码:3408 / 3414
页数:7
相关论文