Hyphenation of column liquid chromatography and Raman spectroscopy via a liquid-core waveguide: chemometrical elimination of spectral eluent background

被引:13
作者
Dijkstra, RJ
Boelens, HFM
Westerhuis, JA
Ariese, F
Brinkman, UAT
Gooijer, C
机构
[1] Vrije Univ Amsterdam, Ctr Laser, Dept Analyt Chem & Appl Spect, NL-1081 HV Amsterdam, Netherlands
[2] Univ Amsterdam, Dept Chem Engn, NL-1018 WV Amsterdam, Netherlands
关键词
Raman spectroscopy; liquid chromatography; liquid-core waveguide; spectral background; library fit;
D O I
10.1016/j.aca.2004.06.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In column liquid chromatography (LC) coupled to conventional Raman spectroscopy (RS) removal of the spectral background of the eluent is often demanding, because of the strong signals of the organic modifier. A new chemometrical method is proposed, called the eluent back-round subtraction (EBS) method, which can correct for small shape and intensity differences of the eluent spectra. The variations in the eluent spectra are modelled using principal component analysis (PCA). The PCA loading vectors are subsequently used for eluent background correction of the elution spectra of the analyte. The loading vectors are fitted under these spectra by an asymmetric least-squares method. This method was successfully applied under various experimental conditions and performed much better than conventional background correction methods. Analyte delectability was improved by (weighted) averaging of all elution spectra and smoothing via a p-spline function. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:129 / 136
页数:8
相关论文
共 16 条
[1]  
BOELENS HFM, UNPUB J CHROMATOGR
[2]   Application of the needle algorithm for exploratory analysis and resolution of HPLC-DAD data [J].
deJuan, A ;
vandenBogaert, B ;
Sanchez, FC ;
Massart, DL .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1996, 33 (02) :133-145
[3]   Liquid-core waveguide technology for coupling column liquid chromatography and Raman spectroscopy [J].
Dijkstra, RJ ;
Slooten, GJ ;
Stortelder, A ;
Buijs, JB ;
Ariese, F ;
Brinkman, UAT ;
Gooijer, G .
JOURNAL OF CHROMATOGRAPHY A, 2001, 918 (01) :25-36
[4]   On-line identification method in column liquid chromatography: UV resonance Raman spectroscopy [J].
Dijkstra, RJ ;
Martha, CT ;
Ariese, F ;
Brinkman, UAT ;
Gooijer, C .
ANALYTICAL CHEMISTRY, 2001, 73 (20) :4977-4982
[5]   On-line coupling of column liquid chromatography and raman spectroscopy using a liquid core waveguide [J].
Dijkstra, RJ ;
Bader, AN ;
Hoornweg, GP ;
Brinkman, UAT ;
Gooijer, C .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4575-4579
[6]   Flexible smoothing with B-splines and penalties [J].
Eilers, PHC ;
Marx, BD .
STATISTICAL SCIENCE, 1996, 11 (02) :89-102
[7]  
EILERS PHC, 1988, KWANTITATIEVE METHOD, V23, P45
[8]  
HARTSTRA J, 1997, THESIS RIKHSUNIVERSI
[9]   Small-volume raman spectroscopy with a liquid core waveguide [J].
Holtz, M ;
Dasgupta, PK ;
Zhang, GF .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2934-2938
[10]   A Raman waveguide detector for liquid chromatography [J].
Marquardt, BJ ;
Vahey, PG ;
Synovec, RE ;
Burgess, LW .
ANALYTICAL CHEMISTRY, 1999, 71 (21) :4808-4814