Four-dimensional superquadric-based cardiac phantom for Monte Carlo simulation of radiological imaging systems

被引:24
作者
Peter, J [1 ]
Gilland, DR [1 ]
Jaszczak, RJ [1 ]
Coleman, RE [1 ]
机构
[1] Duke Univ, Med Ctr, Durham, NC 27110 USA
关键词
D O I
10.1109/23.819306
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A four-dimensional (x,y,z,t) composite superquadric-based object model of the human heart for Monte Carlo simulation of radiological imaging systems has been developed. The phantom models the real temporal geometric conditions of a beating heart for frame rates up to 32 per cardiac cycle. Phantom objects are described by boolean combinations of superquadric ellipsoid sections. Moving spherical coordinate systems are chosen to model wall movement whereby points of the ventricle and atria walls are assumed to move towards a moving center-of-gravity point. Due to the non-static coordinate systems, the atrial/ventricular valve plane of the mathematical heart phantom moves up and down along the left ventricular long axis resulting in reciprocal emptying and filling of atria and ventricles. Compared to the base movement, the epicardial apex as well as the superior atria area are almost fixed in space. Since geometric parameters of the objects are directly applied on intersection calculations of the photon ray with object boundaries during Monte Carlo simulation, no phantom discretization artifacts are involved.
引用
收藏
页码:2211 / 2217
页数:7
相关论文
共 44 条
[21]   Echocardiographic quantification of regional left ventricular wall motion with color kinesis [J].
Lang, RM ;
Vignon, P ;
Weinert, L ;
Bednarz, J ;
Korcarz, C ;
Sandelski, J ;
Koch, R ;
Prater, D ;
MorAvi, V .
CIRCULATION, 1996, 93 (10) :1877-1885
[22]   Regional three-dimensional geometry of the normal human left ventricle using cine computed tomography [J].
Lessick, J ;
Fisher, Y ;
Beyar, R ;
Sideman, S ;
Marcus, ML ;
Azhari, H .
ANNALS OF BIOMEDICAL ENGINEERING, 1996, 24 (05) :583-594
[23]   ECHOCARDIOGRAPHIC MEASUREMENT OF RIGHT VENTRICULAR VOLUME [J].
LEVINE, RA ;
GIBSON, TC ;
ARETZ, T ;
GILLAM, LD ;
GUYER, DE ;
KING, ME ;
WEYMAN, AE .
CIRCULATION, 1984, 69 (03) :497-505
[24]  
MARCASSA C, 1990, J NUCL MED, V31, P173
[26]  
McVeigh Elliot, 1998, Cardiology Clinics, V16, P189, DOI 10.1016/S0733-8651(05)70008-4
[27]  
NAITO H, 1995, BRIT HEART J, V74, P186
[28]   Deformable models with parameter functions for cardiac motion analysis from tagged MRI data [J].
Park, J ;
Metaxas, D ;
Young, AA ;
Axel, L .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (03) :278-289
[29]  
PARK J, 1996, MED IMAGE ANAL J, V1, P1
[30]  
PETER J, 1999, UNPUB IEEE MECH IMAG