Improved detection of lung nodules by using a temporal subtraction technique

被引:43
作者
Kakeda, S
Nakamura, K
Kamada, K
Watanabe, H
Nakata, H
Katsuragawa, S
Doi, K
机构
[1] Univ Occupat & Environm Hlth, Sch Med, Dept Radiol, Yahatanisi Ku, Kitakyushu, Fukuoka 8078555, Japan
[2] Nippon Bunri Univ, Res Ctr, Oita, Japan
[3] Univ Chicago, Dept Radiol, Kurt Rossmann Labs Radiol Image Res, Chicago, IL 60637 USA
关键词
diagnostic radiography; observer performance; diagnostic radiology; lung; abnormalities; lung neoplasms; diagnosis; subtraction; digital;
D O I
10.1148/radiol.2241010719
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the effect of a temporal subtraction technique for digital chest radiography with regard to the accuracy of detection of lung nodules. MATERIALS AND METHODS: Twenty solitary lung nodules smaller than 30 mm in diameter, including 10 lung cancers and 10 benign nodules, were used. The nodules were grouped subjectively according to their subtlety. For nonnodular cases, 20 nodules without perceptible interval changes were selected. All chest radiographs were obtained by using a computed radiographic system, and temporal subtraction images were produced by using a program developed at the University of Chicago. The effect of the temporal subtraction image was evaluated by using an observer performance study, with use of receiver operating characteristic analysis. RESULTS: Observer performance with temporal subtraction images was substantially improved (A(z) = 0.980 and 0.958), as compared with that without temporal subtraction images (A(z) = 0.920 and 0.825) for the certified radiologists and radiology residents, respectively. The temporal subtraction technique clearly improved diagnostic accuracy for detecting lung nodules, especially subtle cases. CONCLUSION: The temporal subtraction technique is useful for improving detection accuracy for peripheral lung nodules on digital chest radiographs. (C) RSNA, 2002.
引用
收藏
页码:145 / 151
页数:7
相关论文
共 25 条
[1]   MISSED BRONCHOGENIC-CARCINOMA - RADIOGRAPHIC FINDINGS IN 27 PATIENTS WITH A POTENTIALLY RESECTABLE LESION EVIDENT IN RETROSPECT [J].
AUSTIN, JHM ;
ROMNEY, BM ;
GOLDSMITH, LS .
RADIOLOGY, 1992, 182 (01) :115-122
[2]   MALPRACTICE AND RADIOLOGISTS, UPDATE 1986 - AN 11.5-YEAR PERSPECTIVE [J].
BERLIN, L .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (06) :1291-1298
[3]  
BROGDON BG, 1983, RADIOL CLIN N AM, V21, P633
[4]   MEDICAL MALPRACTICE CLAIMS IN DIAGNOSTIC-RADIOLOGY - UPDATE [J].
DAHLEN, RT ;
FOLEY, HT .
RADIOLOGY, 1989, 170 (01) :277-277
[5]   Digital chest radiography: Effect of temporal subtraction images on detection accuracy [J].
Difazio, MC ;
MacMahon, H ;
Xu, XW ;
Tsai, P ;
Shiraishi, J ;
Armato, SG ;
Doi, K .
RADIOLOGY, 1997, 202 (02) :447-452
[6]  
FORREST JV, 1981, WESTERN J MED, V134, P485
[7]   MEDICAL MALPRACTICE IN DIAGNOSTIC-RADIOLOGY - CLAIMS, COMPENSATION, AND PATIENT INJURY [J].
HAMER, MM ;
MORLOCK, F ;
FOLEY, HT ;
ROS, PR .
RADIOLOGY, 1987, 164 (01) :263-266
[8]   NON-SMALL-CELL LUNG-CANCER - RESULTS OF THE NEW-YORK SCREENING-PROGRAM [J].
HEELAN, RT ;
FLEHINGER, BJ ;
MELAMED, MR ;
ZAMAN, MB ;
PERCHICK, WB ;
CARAVELLI, JF ;
MARTINI, N .
RADIOLOGY, 1984, 151 (02) :289-293
[9]   Iterative image warping technique for temporal subtraction of sequential chest radiographs to detect interval change [J].
Ishida, T ;
Katsuragawa, S ;
Nakamura, K ;
MacMahon, H ;
Doi, K .
MEDICAL PHYSICS, 1999, 26 (07) :1320-1329
[10]   Application of temporal subtraction for detection of interval changes on chest radiographs: Improvement of subtraction images using automated initial image matching [J].
Ishida, T ;
Ashizawa, K ;
Engelmann, R ;
Katsuragawa, S ;
MacMahon, H ;
Doi, K .
JOURNAL OF DIGITAL IMAGING, 1999, 12 (02) :77-86