Digital chest radiography: Effect of temporal subtraction images on detection accuracy

被引:80
作者
Difazio, MC [1 ]
MacMahon, H [1 ]
Xu, XW [1 ]
Tsai, P [1 ]
Shiraishi, J [1 ]
Armato, SG [1 ]
Doi, K [1 ]
机构
[1] UNIV CHICAGO,DEPT RADIOL,KURT ROSSMANN LABS RADIOL IMAGE RES,CHICAGO,IL 60637
关键词
diagnostic radiology; observer performance; lung; nodule; radiography; lung neoplasms; diagnosis; receiver operating characteristic curve (ROC);
D O I
10.1148/radiology.202.2.9015072
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To improve early detection of disease in chest radiographs, the authors developed a digital processing technique that geometrically warps and subtracts a previous radiograph from a current radiograph to produce a temporal subtraction image. An observer test was performed to evaluate the effects of the temporal subtraction image technique on detection of interval change. MATERIALS AND METHODS: Fifty pairs of chest radiographs, including a baseline examination and a subsequent radiograph, were selected (25 cases in which potentially important new abnormalities had developed, and 25 in which there was no interval change). The baseline examination was chosen from multiple prior radiographs to minimize initial misregistration. By means of receiver operating characteristic (ROC) analysis, the ability of 11 observers to detect pathologic change when viewing the paired digitized baseline and subsequent radiographs was compared with their ability when viewing the same paired radiographs together with temporal subtraction images. Positive cases demonstrated focal new abnormalities that were greater than 1 cm in diameter. RESULTS: The mean area (A(z)) under the ROC curves increased from 0.89 without to 0.98 with the temporal subtraction images. When the paired digitized previous and current chest radiographs were viewed in conjunction with the temporal subtraction images, a significant improvement in detection of new abnormalities was achieved (P = .00004), whereas the mean interpretation time was reduced by 19.3% (from 52 to 42 seconds, including the time to record the score and to move to the next case) (P = .0019). CONCLUSION: The temporal subtraction technique can significantly improve sensitivity and specificity for detection of interval change in chest radiographs.
引用
收藏
页码:447 / 452
页数:6
相关论文
共 15 条
[1]   MISSED BRONCHOGENIC-CARCINOMA - RADIOGRAPHIC FINDINGS IN 27 PATIENTS WITH A POTENTIALLY RESECTABLE LESION EVIDENT IN RETROSPECT [J].
AUSTIN, JHM ;
ROMNEY, BM ;
GOLDSMITH, LS .
RADIOLOGY, 1992, 182 (01) :115-122
[2]   CLASS OF ALGORITHMS FOR FAST DIGITAL IMAGE REGISTRATION [J].
BARNEA, DI ;
SILVERMAN, HF .
IEEE TRANSACTIONS ON COMPUTERS, 1972, C 21 (02) :179-+
[3]   RECEIVER OPERATING CHARACTERISTIC RATING ANALYSIS - GENERALIZATION TO THE POPULATION OF READERS AND PATIENTS WITH THE JACKKNIFE METHOD [J].
DORFMAN, DD ;
BERBAUM, KS ;
METZ, CE .
INVESTIGATIVE RADIOLOGY, 1992, 27 (09) :723-731
[4]   AN INTELLIGENT WORKSTATION FOR COMPUTER-AIDED DIAGNOSIS [J].
GIGER, ML ;
DOI, K ;
MACMAHON, H ;
NISHIKAWA, RM ;
HOFFMANN, KR ;
VYBORNY, CJ ;
SCHMIDT, RA ;
JIA, H ;
ABE, K ;
CHEN, X ;
KANO, A ;
KATSURAGAWA, S ;
YIN, FF ;
ALPERIN, N ;
METZ, CE ;
BEHLEN, FM ;
SLUIS, D .
RADIOGRAPHICS, 1993, 13 (03) :647-656
[5]   MISSED LUNG NODULES - LOST OPPORTUNITIES FOR CANCER CURE [J].
GREENE, RE .
RADIOLOGY, 1992, 182 (01) :8-9
[6]   OBJECTIVE METHODS FOR REGISTERING LANDMARKS AND DETERMINING CLOUD MOTIONS FROM SATELLITE DATA [J].
HALL, DJ ;
WOLF, DE ;
BRAIN, AE ;
ENDLICH, RM .
IEEE TRANSACTIONS ON COMPUTERS, 1972, C 21 (07) :768-+
[7]   EVALUATION OF AN ENHANCED DIGITAL FILM-DUPLICATION SYSTEM BY RECEIVER OPERATING CHARACTERISTIC ANALYSIS [J].
HOFFMANN, KR ;
MACMAHON, H ;
DOI, KN ;
METZ, CE ;
YAO, L ;
ABE, K .
INVESTIGATIVE RADIOLOGY, 1993, 28 (12) :1134-1138
[8]   DIGITAL IMAGE SUBTRACTION OF TEMPORALLY SEQUENTIAL CHEST IMAGES FOR DETECTION OF INTERVAL CHANGE [J].
KANO, A ;
DOI, K ;
MACMAHON, H ;
HASSELL, DD ;
GIGER, ML .
MEDICAL PHYSICS, 1994, 21 (03) :453-461
[9]   THE NATURE AND SUBTLETY OF ABNORMAL FINDINGS IN CHEST RADIOGRAPHS [J].
MACMAHON, H ;
MONTNER, SM ;
DOI, K ;
LIU, KJM .
MEDICAL PHYSICS, 1991, 18 (02) :206-210
[10]  
MACMAHON H, 1993, RADIOLOGY, V189, P430