Miniaturized capillary electrophoresis system with contactless conductivity detection and flow injection sample introduction

被引:11
作者
Wang, LX
Fu, CG [1 ]
机构
[1] Liaocheng Univ, Dept Chem, Shandong 252059, Peoples R China
[2] Liaocheng Univ, Dept Educ Technol, Shandong 252059, Peoples R China
关键词
capillary electrophoresis; flow injection; conductivity detection; surface water;
D O I
10.1081/CI-120030542
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A miniaturized capillary electrophoresis (CE) system with contactless conductivity detection (CCD) and flow injection (FI) sample introduction was developed. It represents an ideal combination of high-resolution separation of CE with high throughput reproducible sample injection of FI, and universal and robust detection of CCD for the analysis of ionic species. Its design and fabrication method is described in detail. Performance tests of the system were performed for the analysis of surface water. It was found that complete separation of the cations studied (NH4+, K+, Ca2+, Na+, and Mg2+) could be obtained within 60 see with peak height RSD better than(.)2.0%, thus achieving a sampling frequency of 60 hr(-1). Detection limits were in the order of low micro molarity.
引用
收藏
页码:303 / 309
页数:7
相关论文
共 15 条
[1]  
da Silva JAF, 2002, J CHROMATOGR A, V942, P249
[2]  
da Silva JAF, 1998, ANAL CHEM, V70, P4339
[3]   Sequential injection sample introduction microfluidic-chip based capillary electrophoresis system [J].
Fang, Q ;
Wang, FR ;
Wang, SL ;
Liu, SS ;
Xu, SK ;
Fang, ZL .
ANALYTICA CHIMICA ACTA, 1999, 390 (1-3) :27-37
[4]   Combination of flow injection with capillary electrophoresis - Part 7. Microchip capillary electrophoresis system with flow injection sample introduction and amperometric detection [J].
Fu, CG ;
Fang, ZL .
ANALYTICA CHIMICA ACTA, 2000, 422 (01) :71-79
[5]  
HUANG X, 1988, J CHROMATOGR, V480, P285
[6]   END-COLUMN DETECTION FOR CAPILLARY ZONE ELECTROPHORESIS [J].
HUANG, XH ;
ZARE, RN ;
SLOSS, S ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1991, 63 (02) :189-192
[7]   QUANTITATIVE-ANALYSIS OF LOW-MOLECULAR WEIGHT CARBOXYLIC-ACIDS BY CAPILLARY ZONE ELECTROPHORESIS CONDUCTIVITY DETECTION [J].
HUANG, XH ;
LUCKEY, JA ;
GORDON, MJ ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1989, 61 (07) :766-770
[8]   ON-COLUMN CONDUCTIVITY DETECTOR FOR CAPILLARY ZONE ELECTROPHORESIS [J].
HUANG, XH ;
PANG, TKJ ;
GORDON, MJ ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1987, 59 (23) :2747-2749
[9]   QUANTITATION OF LI+ IN SERUM BY CAPILLARY ZONE ELECTROPHORESIS WITH AN ON-COLUMN CONDUCTIVITY DETECTOR [J].
HUANG, XH ;
GORDON, MJ ;
ZARE, RN .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 425 (02) :385-390
[10]   Combination of flow injection with capillary electrophoresis 8. Miniaturized capillary electrophoresis system with flow injection sample introduction and electrogenerated chemiluminescence detection [J].
Huang, XJ ;
Wang, SL ;
Fang, ZL .
ANALYTICA CHIMICA ACTA, 2002, 456 (02) :167-175