Sequential injection sample introduction microfluidic-chip based capillary electrophoresis system

被引:72
作者
Fang, Q [1 ]
Wang, FR [1 ]
Wang, SL [1 ]
Liu, SS [1 ]
Xu, SK [1 ]
Fang, ZL [1 ]
机构
[1] Northeastern Univ, Res Ctr Analyt Sci, Shenyang 110006, Peoples R China
关键词
sequential injection; capillary electrophoresis; microfluidics; microchips; amino acids;
D O I
10.1016/S0003-2670(99)00183-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sequential injection micro-sample introduction system was coupled to a microfluidic-chip based capillary electrophoresis system through a split-flow sampling interface integrated on the micro-chip. The microfluidic system measured 20x70x3 mm in dimension, and was produced using a non-lithographic approach with components readily available in the analytical laboratory. In the H-configuration channel design the horizontal separation channel was a 75 mu m I.D. x 60 mm quartz capillary, with two vertical side arms produced from plastic tubing. The conduits were embedded in silicon elastomer with a planar glass base. Sequential introduction of a series of samples with about 2.5% carryover was achieved at 48 h(-1) throughput with samples containing a mixture of fluorescein isothiocyanate (FITC)-labeled amino acids using SI sample volumes of 3.3 mu l and carrier flow-rate of 2.0 ml min(-1). Baseline separation was achieved for FITC-labeled arginine, phenylalanine, glycine and FITC (laser induced fluorescence detection) in sodium tetraborate buffer (pH 9.2) within 8-80 s, at separation lengths of 25-35 mm and electrical field strengths of 250-1500 V cm(-1), with plate heights in the 0.7-3 mu m range. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:27 / 37
页数:11
相关论文
共 18 条
  • [1] An integrated nanoliter DNA analysis device
    Burns, MA
    Johnson, BN
    Brahmasandra, SN
    Handique, K
    Webster, JR
    Krishnan, M
    Sammarco, TS
    Man, PM
    Jones, D
    Heldsinger, D
    Mastrangelo, CH
    Burke, DT
    [J]. SCIENCE, 1998, 282 (5388) : 484 - 487
  • [2] Combination of flow injection with capillary electrophoresis. Part 3. On-line sorption column preconcentration capillary electrophoresis system
    Chen, HW
    Fang, ZL
    [J]. ANALYTICA CHIMICA ACTA, 1997, 355 (2-3) : 135 - 143
  • [3] Dempsey E, 1997, ANAL CHIM ACTA, V346, P341
  • [4] GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS
    EFFENHAUSER, CS
    MANZ, A
    WIDMER, HM
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (19) : 2637 - 2642
  • [5] Integrated capillary electrophoresis on flexible silicone microdevices: Analysis of DNA restriction fragments and detection of single DNA molecules on microchips
    Effenhauser, CS
    Bruin, GJM
    Paulus, A
    Ehrat, M
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (17) : 3451 - 3457
  • [6] Combination of flow injection with capillary electrophoresis .1. The basic system
    Fang, ZL
    Liu, ZS
    Shen, Q
    [J]. ANALYTICA CHIMICA ACTA, 1997, 346 (02) : 135 - 143
  • [7] CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP
    HARRISON, DJ
    MANZ, A
    FAN, ZH
    LUDI, H
    WIDMER, HM
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (17) : 1926 - 1932
  • [8] HIGH-SPEED SEPARATIONS ON A MICROCHIP
    JACOBSON, SC
    HERGENRODER, R
    KOUTNY, LB
    RAMSEY, JM
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (07) : 1114 - 1118
  • [9] MICROCHIP CAPILLARY ELECTROPHORESIS WITH AN INTEGRATED POSTCOLUMN REACTOR
    JACOBSON, SC
    KOUTNY, LB
    HERGENRODER, R
    MOORE, AW
    RAMSEY, JM
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (20) : 3472 - 3476
  • [10] Chemical amplification: Continuous-flow PCR on a chip
    Kopp, MU
    de Mello, AJ
    Manz, A
    [J]. SCIENCE, 1998, 280 (5366) : 1046 - 1048