摘要
Background: We believe that direct intraneural stimulation of the modiolar nerve using an array of electrodes will have lower thresholds, offer greater frequency selectivity and more stimulation sites, and have a greater frequency representation than conventional cochlear implants. Objectives: To describe a potential auditory prosthesis based on electrical stimulation of the modiolar cochlear nerve and to report the development of a surgical approach in human and animal models. Design: Cadaveric human and animal studies conducted in temporal bones indicated that an array of penetrating microelectrodes could be implanted in the modiolar nerve. Cat studies using anesthesia were performed to develop the surgical procedure in an animal model. Nerve viability was assessed by measurement of electrically evoked auditory brainstem responses at different stages of the surgery. Subjects: Two fresh cadaveric human temporal bones, 3 cat cadavers, 1 pig cadaver, and 6 anesthetized cats were used in the experiments. Results: We were able to implant arrays containing 20 microelectrodes in the human modiolar nerve after exposure by a modified extended facial recess approach. In animals, the modiolar nerve was accessed by the transbulla and the middle fossa approach. The cat was chosen as the appropriate animal model, and the transbulla approach was selected. The round window was exposed by ventral access to the bulla and after cochleostomy; drilling the modiolar bone exposed the modiolar nerve. The mean+/-SD diameter of the exposed nerve in cats was 1.64+/-0.07 mm (n = 9), and the mean+/-SD exposed length was 2.50+/-0.11 mm (n=9); this is adequate to accommodate 20 microelectrodes. The electrically evoked auditory brainstem responses indicated nerve survival during and after the surgery. Conclusions: The surgical technique allows implantation of up to 20 microelectrodes in the cat and human modiolar nerve. The nerve survives the surgical procedure. This work enables studies in the electrophysiological properties and consequences of long-term implantation.
引用
收藏
页码:1019 / 1025
页数:7
相关论文
共 23 条
[1]   AUDITORY BRAIN STEM RESPONSES IN THE CAT. II. EFFECTS OF LESIONS [J].
ACHOR, LJ ;
STARR, A .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1980, 48 (02) :174-190
[2]   AUDITORY BRAIN STEM RESPONSES IN THE CAT. I. INTRACRANIAL AND EXTRACRANIAL RECORDINGS [J].
ACHOR, LJ ;
STARR, A .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1980, 48 (02) :154-173
[3]  
[Anonymous], 1970, CIBA FDN S SENS HEAR, DOI DOI 10.1002/9780470719756.CH15
[4]   CURRENT DISTRIBUTIONS IN COCHLEAR STIMULATION [J].
BLACK, RC ;
CLARK, GM ;
TONG, YC ;
PATRICK, JF .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1983, 405 (JUN) :137-145
[5]   Selective stimulation of cat sciatic nerve using an array of varying-length microelectrodes [J].
Branner, A ;
Stein, RB ;
Normann, RA .
JOURNAL OF NEUROPHYSIOLOGY, 2001, 85 (04) :1585-1594
[6]   A SILICON-BASED, 3-DIMENSIONAL NEURAL INTERFACE - MANUFACTURING PROCESSES FOR AN INTRACORTICAL ELECTRODE ARRAY [J].
CAMPBELL, PK ;
JONES, KE ;
HUBER, RJ ;
HORCH, KW ;
NORMANN, RA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (08) :758-768
[7]   COCHLEAR IMPLANTS IN ADULTS AND CHILDREN [J].
GATES, GA ;
DALY, K ;
DICHTEL, WJ ;
DOOLING, RJ ;
GULYA, AJ ;
HALL, JW ;
JERGER, SW ;
JONES, JE ;
MAYER, MH ;
PIERSCHALLA, M ;
ROSS, LF ;
SCHWARTZ, RG ;
WEINSTEIN, BE ;
YOUNG, ED ;
ABBAS, PJ ;
BLAMEY, P ;
BRACKMANN, DE ;
BRIMACOMBE, JA ;
CHUTE, PM ;
COHEN, NL ;
DORMAN, MF ;
EDDINGTON, DK ;
GANTZ, BJ ;
HELLER, JW ;
KETTEN, DR ;
KNUTSON, JF ;
LEAKE, PA ;
MCDERMOTT, HJ ;
MIYAMOTO, RT ;
MOOG, JS ;
OSBERGER, MJ ;
SHANNON, RV ;
SKINNER, MW ;
SUMMERFIELD, Q ;
TOBEY, EA ;
WILSON, BS ;
ZWOLAN, TA ;
DONAHUE, AH ;
ALLEN, MP ;
BECK, LB ;
BRAY, EA ;
COOPER, JA ;
FERGUSON, JH ;
FLACK, MN ;
HALL, WH ;
HAMBRECHT, FT ;
KRASNEGOR, N ;
MONJAN, AA ;
NAUNTON, RF ;
SNOW, JB .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 274 (24) :1955-1961
[8]  
Gstoettner WK, 2001, ACTA OTO-LARYNGOL, V121, P216
[9]   Statistical pattern recognition: A review [J].
Jain, AK ;
Duin, RPW ;
Mao, JC .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2000, 22 (01) :4-37
[10]   SHAPES OF TUNING CURVES FOR SINGLE AUDITORY-NERVE FIBERS [J].
KIANG, NYS ;
SACHS, MB ;
PEAKE, WT .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1967, 42 (06) :1341-&