Improved signal-to-noise ratio in glow discharge ion trap mass spectrometry via pulsed discharge operation's

被引:21
作者
Duckworth, DC
Smith, DH
McLuckey, SA
机构
[1] Chem. and Analyt. Sciences Division, Oak Ridge National Laboratory, Oak Ridge
关键词
glow discharge ion trap mass spectrometry; elemental analysis; direct solids analysis; noise; pulsed discharge; gated ion injection;
D O I
10.1039/a605312b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An improvement in the S/N ratio is reported for the analysis of trace elements in brass by glow discharge ion trap mass spectrometry, This was achieved by synchronizing the pulsed discharge voltage with the ion injection and acquisition events; 'on' during ion injection and 'off' during data acquisition, Two modes of operation were Evaluated: (1) a high duty cycle pulse, which allowed a continuous injection over the duration of the;pulse; and (2) a low duty cycle pulse with multiple data gates, which allowed gated injections of ions at selected regions of the pulse profile, The latter afforded a means of selective ion injection since discharge and;residual gas species are formed at different times in the pulse event than analyte ions, Improvements in S/N ratios greater than 40-fold were observed, primarily due to a reduction in background and background noise after the discharge was extinguished. Evidence is presented which suggests that electrons emanating from the ion source are the precursors of most of the noise, Detection limits for various elements were 0.2-0.5 ppm.
引用
收藏
页码:43 / 48
页数:6
相关论文
共 27 条
[1]   LASER-DESORPTION IN A QUADRUPOLE ION-TRAP - MIXTURE ANALYSIS USING POSITIVE AND NEGATIVE-IONS [J].
ALEXANDER, ML ;
HEMBERGER, PH ;
CISPER, ME ;
NOGAR, NS .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :1609-1614
[2]  
APPELHANS AD, 1996, SIMS, V10
[3]   ION-TRAP MASS-SPECTROMETRY WITH AN INDUCTIVELY-COUPLED PLASMA SOURCE [J].
BARINAGA, CJ ;
KOPPENAAL, DW .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (01) :71-76
[4]   DYNAMIC-RANGE EXTENSION IN GLOW-DISCHARGE QUADRUPOLE ION-TRAP MASS-SPECTROMETRY [J].
DUCKWORTH, DC ;
BARSHICK, CM ;
SMITH, DH ;
MCLUCKEY, SA .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :92-98
[5]   DIRECT INSERTION PROBE FOR RADIOFREQUENCY POWERED GLOW-DISCHARGE MASS-SPECTROMETRY [J].
DUCKWORTH, DC ;
MARCUS, RK .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (04) :711-715
[6]   Selective removal of plasma matrix ions in plasma source mass spectrometry [J].
Eiden, GC ;
Barinaga, CJ ;
Koppenaal, DW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (04) :317-322
[7]  
Frum C. I, 1996, 44 ASMS C MASS SPECT
[8]   Selective ionization for elemental analysis with an ion trap mass spectrometer [J].
Garrett, AW ;
Hemberger, PH ;
Nogar, NS .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (14) :1889-1895
[9]   ATOMIC MASS-SPECTROMETRY OF SOLID SAMPLES USING LASER ABLATION-ION TRAP MASS-SPECTROMETRY (LAITMS) [J].
GILL, CG ;
DAIGLE, B ;
BLADES, MW .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (08) :1227-1235
[10]   LASER ABLATION ION-TRAP MASS-SPECTROMETRY - ATOMIC AND MOLECULAR MASS-SPECTROMETRY OF METAL, CERAMIC AND POLYMER SAMPLES [J].
GILL, CG ;
BLADES, MW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (02) :261-267