Vectorcardiographic loop alignment and the measurement of morphologic beat-to-beat variability in noisy signals

被引:35
作者
Åström, M
Santos, EC
Sörnmo, L
Laguna, P
Wohlfart, B
机构
[1] Univ Lund, Signal Proc Grp, Dept Appl Elect, S-22100 Lund, Sweden
[2] Univ Zaragoza, Commun Technol Grp, Dept Elect Engn & Commun, Zaragoza, Spain
[3] Univ Lund, Dept Clin Physiol, S-22100 Lund, Sweden
关键词
ECG signal processing; morphologic beat-to-beat variability; noise performance; VCG loop alignment;
D O I
10.1109/10.828149
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The measurement of subtle morphologic beat-to-beat variability in the electrocardiogram (ECG)/vectorcardiogram (VCG) is complicated by the presence of noise which is caused by, e.g., respiration and muscular activity. A method was recently presented which reduces the influence of such noise by performing spatial and temporal alignment of VCG loops, The alignment is performed in terms of scaling, rotation and time synchronization of the loops. Using an ECG simulation model based on propagation of action potentials in cardiac tissue, the ability of the method to separate morphologic variability of physiological origin from respiratory activity was studied. Morphologic variability was created by introducing a random variation in action potential propagation between different compartments. The results indicate that the separation of these two activities can be done accurately at low to moderate noise levels (less than 10 mu V) At high noise levels, the estimation of the rotation angles was found to break down in an abrupt manner. It was also shown that the breakdown noise level is strongly dependent on loop morphology; a planar loop corresponds to a lower breakdown noise level than does a nonplanar loop.
引用
收藏
页码:497 / 506
页数:10
相关论文
共 15 条
[1]  
ASTROM M, 1998, SPR42 LUND U
[2]   BEAT-TO-BEAT ELECTROCARDIOGRAPHIC MORPHOLOGY VARIATION IN HEALED MYOCARDIAL-INFARCTION [J].
BENHAIM, SA ;
BECKER, B ;
EDOUTE, Y ;
KOCHANOVSKI, M ;
AZARIA, O ;
KAPLINSKY, E ;
PALTI, Y .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (08) :725-728
[3]   VECTORCARDIOGRAM SYNTHESIZED FROM A 12-LEAD ECG - SUPERIORITY OF THE INVERSE DOWER MATRIX [J].
EDENBRANDT, L ;
PAHLM, O .
JOURNAL OF ELECTROCARDIOLOGY, 1988, 21 (04) :361-367
[4]  
Fayn J., 1983, Computers in Cardiology 10th Annual Meeting (IEEE Cat. No. 83CH1927-3), P467
[5]   Non-invasive assessment of the atrial cycle length during atrial fibrillation in man:: introducing, validating and illustrating a new ECG method [J].
Holm, M ;
Pehrson, S ;
Ingemansson, M ;
Sörnmo, L ;
Johansson, R ;
Sandhall, L ;
Sunemark, M ;
Smideberg, B ;
Olsson, SB .
CARDIOVASCULAR RESEARCH, 1998, 38 (01) :69-81
[6]  
MACFARLANE P, 1994, 12 LEAD VECTORCARDIO
[7]  
Malmivuo J., 1995, Bioelectromagnetism: Principles and Applications of Bioelectric and Biomagnetic Fields, P365, DOI 10.1093/acprof:oso/9780195058239.001.0001
[8]   PHASE-INVARIANT SIGNATURE ALGORITHM - NON-INVASIVE TECHNIQUE FOR EARLY DETECTION AND QUANTIFICATION OF OUABAIN-INDUCED CARDIAC DISORDERS [J].
PRASAD, K ;
GUPTA, MM .
ANGIOLOGY, 1979, 30 (11) :721-732
[9]  
RUBEL P, 1993, J ELECTROCARDIOL, V26, P122
[10]   ON THE DETECTION OF QRS VARIATIONS IN THE ECG [J].
SHAW, GR ;
SAVARD, P .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (07) :736-741