Gamma radiation induces positive vascular remodeling after balloon angioplasty: A prospective, randomized intravascular ultrasound scan study

被引:17
作者
Hagenaars, T
Po, IFLA
van Sambeek, MRHM
Coen, VLMA
van Tongeren, RBM
Gescher, FM
Wittens, CHA
Boelhouwer, RU
Pattynama, PMT
Gussenhoven, EJ
机构
[1] Erasmus Med Ctr, Dept Expt Echocardiog, NL-3000 DR Rotterdam, Netherlands
[2] Erasmus Med Ctr, Dept Vasc Surg, NL-3000 DR Rotterdam, Netherlands
[3] Erasmus Med Ctr, Dept Radiotherapy, NL-3000 DR Rotterdam, Netherlands
[4] Erasmus Med Ctr, Dept Radiol, NL-3000 DR Rotterdam, Netherlands
[5] Leyenburg Hosp, Dept Radiol, The Hague, Netherlands
[6] Leyenburg Hosp, Dept Vasc Surg, The Hague, Netherlands
[7] Leyenburg Hosp, Dept Radiotherapy, The Hague, Netherlands
[8] St Franciscus Hosp, Dept Vasc Surg, Rotterdam, Netherlands
[9] Ikazia Hosp, Dept Vasc Surg, Rotterdam, Netherlands
[10] Interuniv Cardiol Inst, Rotterdam, Netherlands
关键词
D O I
10.1067/mva.2002.124373
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Endovascular brachytherapy (EBT) has been shown to prevent restenosis after percutaneous transluminal coronary angioplasty (PTA) in both animal and clinical studies. However, as yet, the effect of EBT on peripheral arteries is unknown. Objective: This intravascular ultrasound scan (IVUS) study evaluates the effect of EBT on the extent of plaque growth and vascular remodeling after PTA of the femoropopliteal artery. Methods: Twenty-four patients with obstructive disease of the femoropopliteal artery underwent standard PTA. Patients were randomized to receive no additional therapy or additional EBT (192-Iridium) after PTA. IVUS investigation was performed after PTA and at 6-month follow-up. A comparison was made between patients without EBT (n = 16) and with EBT (n = 8) in the change in lumen, vessel, and plaque area and plaque dissections seen with IVUS at 6-month follow-up. Results: At follow-up, IVUS revealed a significant difference in lumen area change between patients without and with EBT (-9% and +23%, respectively; P = .03). This difference was the result of a significant difference in vessel area change (+2% and +19%, respectively; P = .05). In both groups of patients, a similar increase in plaque area (+12% and +16%, respectively; P = .80) was encountered. Plaque dissections encountered immediately after PTA were absent at follow-up in patients without EBT, whereas in four of the eight patients with EBT, a persistent dissection was encountered. Conclusion: This randomized IVUS study showed that gamma-radiation after PTA has a positive effect on lumen dimensions at 6-month follow-up by inducing positive vascular remodeling (ie, vascular dilatation); gamma-radiation seemed not to affect plaque growth. In addition, gamma-radiation has an effect on the healing process of dissections after PTA.
引用
收藏
页码:318 / 324
页数:7
相关论文
共 35 条
[1]   Safety of intracoronary γ-radiation on uninjured reference segments during the first 6 months after treatment of in-stent restenosis -: A serial intravascular ultrasound study [J].
Ahmed, JM ;
Mintz, GS ;
Waksman, R ;
Weissman, NJ ;
Mehran, R ;
Pichard, AD ;
Satler, LF ;
Kent, KM ;
Leon, MB .
CIRCULATION, 2000, 101 (19) :2227-2230
[2]  
CAPEK P, 1991, CIRCULATION S1, V83, P170
[3]  
Condado JA, 1997, CIRCULATION, V96, P727
[4]   QUANTITATIVE ASSESSMENT WITH INTRACORONARY ULTRASOUND OF THE MECHANISMS OF RESTENOSIS AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY AND DIRECTIONAL CORONARY ATHERECTOMY [J].
DIMARIO, C ;
GIL, R ;
CAMENZIND, E ;
OZAKI, Y ;
VONBIRGELEN, C ;
UMANS, V ;
DEJAEGERE, P ;
DEFEYTER, PJ ;
ROELANDT, JRTC ;
SERRUYS, PW .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (12) :772-777
[5]   Reproducibility of volumetric quantification in intravascular ultrasound images [J].
Hagenaars, T ;
Gussenhoven, EJ ;
van Essen, JA ;
Seelen, J ;
Honkoop, J ;
van der Lugt, A .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (03) :367-374
[6]   Positive geometric vascular remodeling is seen after catheter-based radiation followed by conventional stent implantation but not after radioactive stent implantation [J].
Kay, IP ;
Sabaté, M ;
Costa, MA ;
Kozuma, K ;
Albertal, M ;
van der Giessen, WJ ;
Wardeh, AJ ;
Ligthart, JMR ;
Coen, VMA ;
Levendag, PC ;
Serruys, PW .
CIRCULATION, 2000, 102 (12) :1434-1439
[7]   Outcome from balloon induced coronary artery dissection after intracoronary β radiation [J].
Kay, IP ;
Sabate, M ;
Van Langenhove, G ;
Costa, MA ;
Wardeh, AJ ;
Gijzel, AL ;
Deshpande, NV ;
Carlier, SG ;
Coen, VLMA ;
Levendag, PC ;
Van der Giessen, W ;
de Feyter, PJ ;
Serruys, PW .
HEART, 2000, 83 (03) :332-337
[8]  
Kimura T, 1997, CIRCULATION, V96, P475
[9]   Endovascular β-radiation to reduce restenosis after coronary balloon angioplasty -: Results of the beta energy restenosis trial (BERT) [J].
King, SB ;
Williams, DO ;
Chougule, P ;
Klein, JL ;
Waksman, R ;
Hilstead, R ;
Macdonald, J ;
Anderberg, K ;
Crocker, IR .
CIRCULATION, 1998, 97 (20) :2025-2030
[10]   Three-dimensional intravascular ultrasound assessment of noninjured edges of β-irradiated coronary segments [J].
Kozuma, K ;
Costa, MA ;
Sabaté, M ;
Kay, IP ;
Marijnissen, JPA ;
Coen, VLMA ;
Serrano, P ;
Ligthart, JMR ;
Levendag, PC ;
Serruys, PW .
CIRCULATION, 2000, 102 (13) :1484-1489