Electrospray tandem mass spectrometry of intact β-chain hemoglobin variants

被引:26
作者
Rai, DK
Landin, B
Alvelius, G
Griffiths, WJ [1 ]
机构
[1] Karolinska Inst, Dept Med Biochem & Biophys, SE-17177 Stockholm, Sweden
[2] Huddinge Univ Hosp, Div Clin Chem, Dept Med Lab Sci & Technol, SE-14186 Stockholm, Sweden
关键词
D O I
10.1021/ac011068f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this report, we present data to illustrate how human hemoglobin (Hb) variants can be identified by electrospray tandem mass spectrometry (MS/MS) of the intact Hb chains following the one-step dilution of whole blood. MS/ MS spectra were recorded on a series of intact beta-chain human Hb variants. The resultant spectra were interpreted, and using the information gleaned from the fragmentation patterns of known variants, two unknown beta-chain variants were characterized solely by this mass spectrometric method. Fragment ions that serve to identify beta-chain variants were identified. The fragmentation patterns of the intact beta-chain [M + 18H](18+) ions showed classical facile cleavages adjacent to acidic residues and N-terminal to proline residues, with Thr50-Pro51 being the most prominent cleavage site. Abundant product ions were formed by peptide bond cleavage in the regions close to the termini of the beta chain, the central region being less well-represented in the MS/MS spectra. Nearly 50% of the beta-chain primary structure could be determined by MS/ MS of the intact chain. However, analysis of the Hb variants where mutations have occurred in the inner region (residues 58-111) of the beta globin proved to be difficult and required mass spectrometric analysis of their tryptic peptides for a complete identification.
引用
收藏
页码:2097 / 2102
页数:6
相关论文
共 25 条
[1]   CONTRIBUTIONS OF MASS-SPECTROMETRY TO PEPTIDE AND PROTEIN-STRUCTURE [J].
BIEMANN, K .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 16 (1-12) :99-111
[2]  
Bunn HF., 1986, HEMOGLOBIN MOL GENET
[3]  
COOKS RG, 1991, RAPID COMMUN MASS SP, V5, P93
[4]   Influence of peptide composition, gas-phase basicity, and chemical modification on fragmentation efficiency: Evidence for the mobile proton model [J].
Dongre, AR ;
Jones, JL ;
Somogyi, A ;
Wysocki, VH .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (35) :8365-8374
[5]   DISENTANGLING ELECTROSPRAY SPECTRA WITH MAXIMUM-ENTROPY [J].
FERRIGE, AG ;
SEDDON, MJ ;
GREEN, BN ;
JARVIS, SA ;
SKILLING, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (11) :707-711
[6]   RARE BETA-CHAIN HEMOGLOBIN-VARIANTS FOUND IN SWEDISH PATIENTS DURING HBA(1C) ANALYSIS [J].
LANDIN, B ;
JEPPSSON, JO .
HEMOGLOBIN, 1993, 17 (04) :303-318
[7]   Use of a polybrene capillary coating in capillary electrophoresis for rapid analysis of hemoglobin variants with on-line detection via an ion trap storage reflectron time-of-flight mass spectrometer [J].
Li, MX ;
Liu, L ;
Wu, JT ;
Lubman, DM .
ANALYTICAL CHEMISTRY, 1997, 69 (13) :2451-2456
[8]   COLLISIONALLY ACTIVATED DISSOCIATION AND TANDEM MASS-SPECTROMETRY OF INTACT HEMOGLOBIN BETA-CHAIN VARIANT PROTEINS WITH ELECTROSPRAY IONIZATION [J].
LIGHTWAHL, KJ ;
LOO, JA ;
EDMONDS, CG ;
SMITH, RD ;
WITKOWSKA, HE ;
SHACKLETON, CHL ;
WU, CSC .
BIOLOGICAL MASS SPECTROMETRY, 1993, 22 (02) :112-120
[9]   TANDEM MASS-SPECTROMETRY OF VERY LARGE MOLECULES .2. DISSOCIATION OF MULTIPLY CHARGED PROLINE-CONTAINING PROTEINS FROM ELECTROSPRAY IONIZATION [J].
LOO, JA ;
EDMONDS, CG ;
SMITH, RD .
ANALYTICAL CHEMISTRY, 1993, 65 (04) :425-438
[10]  
Rai DK, 2001, CLIN CHEM, V47, P1308