Clinical utility and safety of a protocol for noncardiac and cardiac magnetic resonance imaging of patients with permanent pacemakers and implantable- cardioverter defibrillators at 1.5 tesla

被引:250
作者
Nazarian, Saman
Roguin, Ariel
Zviman, Menekhem M.
Lardo, Albert C.
Dickfeld, Timm L.
Calkins, Hugh
Weiss, Robert G.
Berger, Ronald D.
Bluemke, David A.
Halperin, Henry R.
机构
[1] Johns Hopkins Univ Hosp, Div Cardiol, Dept Med Cardiol, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ Hosp, Dept Radiol, Baltimore, MD 21287 USA
[3] Johns Hopkins Univ Hosp, Dept Surg, Baltimore, MD 21287 USA
[4] Johns Hopkins Univ Hosp, Dept Biomed Engn, Baltimore, MD 21287 USA
关键词
magnetic resonance imaging; pacemakers; defibrillators; implantable;
D O I
10.1161/CIRCULATIONAHA.105.607655
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Magnetic resonance imaging (MRI) is an important diagnostic modality currently unavailable for millions of patients because of the presence of implantable cardiac devices. We sought to evaluate the diagnostic utility and safety of noncardiac and cardiac MRI at 1.5T using a protocol that incorporates device selection and programming and limits the estimated specific absorption rate of MRI sequences. Methods and Results-Patients with no imaging alternative and with devices shown to be MRI safe by in vitro phantom and in vivo animal testing were enrolled. Of 55 patients who underwent 68 MRI studies, 31 had a pacemaker, and 24 had an implantable defibrillator. Pacing mode was changed to "asynchronous" for pacemaker-dependent patients and to "demand" for others. Magnet response and tachyarrhythmia functions were disabled. Blood pressure, ECG, oximetry, and symptoms were monitored. Efforts were made to limit the system-estimated whole-body average specific absorption rate to 2.0 W/ kg (successful in > 99% of sequences) while maintaining the diagnostic capability of MRI. No episodes of inappropriate inhibition or activation of pacing were observed. There were no significant differences between baseline and immediate or long-term (median 99 days after MRI) sensing amplitudes, lead impedances, or pacing thresholds. Diagnostic questions were answered in 100% of nonthoracic and 93% of thoracic studies. Clinical findings included diagnosis of vascular abnormalities (9 patients), diagnosis or staging of malignancy (9 patients), and assessment of cardiac viability (13 patients). Conclusions-Given appropriate precautions, noncardiac and cardiac MRI can potentially be safely performed in patients with selected implantable pacemaker and defibrillator systems.
引用
收藏
页码:1277 / 1284
页数:8
相关论文
共 44 条
[1]   Cardiac resynchronization in chronic heart failure [J].
Abraham, WT ;
Fisher, WG ;
Smith, AL ;
Delurgio, DB ;
Leon, AR ;
Loh, E ;
Kocovic, DZ ;
Packer, M ;
Clavell, AL ;
Hayes, DL ;
Ellestad, M ;
Messenger, J ;
Trupp, RJ ;
Underwood, J ;
Pickering, F ;
Truex, C ;
McAtee, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (24) :1845-1853
[2]   Implantable cardioverter defibrillator dysfunction during and after magnetic resonance imaging [J].
Anfinsen, OG ;
Berntsen, RF ;
Aass, H ;
Kongsgaard, E ;
Amlie, JP .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (09) :1400-1402
[3]  
Avery J K, 1988, J Tenn Med Assoc, V81, P523
[4]   Evaluation of specific absorption rate as a dosimeter of MRI-related implant heating [J].
Baker, KB ;
Tkach, JA ;
Nyenhuis, JA ;
Phillips, M ;
Shellock, FG ;
Gonzalez-Martinez, J ;
Rezai, AR .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (02) :315-320
[5]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[6]   Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure [J].
Bristow, MR ;
Saxon, LA ;
Boehmer, J ;
Krueger, S ;
Kass, DA ;
De Marco, T ;
Carson, P ;
DiCarlo, L ;
DeMets, D ;
White, BG ;
DeVries, DW ;
Feldman, AM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) :2140-2150
[7]   Epidemiology of pacemaker procedures among medicare enrollees in 1990, 1995, and 2000 [J].
Brown, DW ;
Croft, JB ;
Giles, WH ;
Anda, RF ;
Mensah, GA .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (03) :409-411
[8]   Implantable cardiac defibrillator interactions with magnetic resonance imaging at 1.5 Tesla [J].
Coman, JA ;
Martin, ET ;
Sandler, DA ;
Thomas, JR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) :138A-138A
[9]   Is magnetic resonance imaging safe in cardiac pacemaker recipients? [J].
Del Ojo, JL ;
Moya, F ;
Villalba, J ;
Sanz, O ;
Pavón, R ;
Garcia, D ;
Pastor, L .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (04) :274-278
[10]   EFFECT OF MAGNETIC-RESONANCE-IMAGING ON DDD PACEMAKERS [J].
ERLEBACHER, JA ;
CAHILL, PT ;
PANNIZZO, F ;
KNOWLES, RJR .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 57 (06) :437-440