An electrochemiluminescence-based fibre optic biosensor for choline flow injection analysis

被引:70
作者
Tsafack, VC [1 ]
Marquette, CA [1 ]
Leca, B [1 ]
Blum, LJ [1 ]
机构
[1] Univ Lyon 1, CNRS, UMR 5013, Lab Genie Enzymat, F-69622 Villeurbanne, France
关键词
D O I
10.1039/a907709j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fibre optic biosensor based on luminol electrochemiluminescence (ECL) integrated in a flow injection analysis (FIA) system was developed for the detection of choline. The electrochemiluminescence of luminol was generated by a glassy carbon electrode polarised at +425 mV vs. a platinum pseudo-reference electrode. Choline oxidase (Chx) was immobilised either covalently on polyamide (ABC type) or on UltraBind preactivated membranes, or by physical entrapment in a photo-cross-linkable poly(vinyl alcohol) polymer (PVA-SbQ) alone or after absorption on a weak anion exchanger, DEAE (diethylaminoethyl) Sepharose. The optimisation of the reaction conditions and physicochemical parameters influencing the FIA biosensor response demonstrated that the choline biosensor exhibited the best performances in a 30 mM veronal buffer containing 30 mM KCl and 1.5 mM MgCl2, at pH 9. The use of a 0.5 ml min(-1) flow rate enabled the measurement of choline by the membrane-based ECL biosensors in 8 or 5 min, with ABC or UltraBind membranes, respectively, whereas the measurement required only 3 min with the DEAE-PVA system. For comparison, the detection of choline was performed with Chx immobilised using the four different supports. The best performances were obtained with the DEAE-PVA-Chx sensing layer, which allowed a detection limit of 10 pmol, whereas with the ABC, the UltraBind and the PVA systems, the detection limits were 300 pmol, 75 pmol and 220 pmol, respectively. The DEAE-based system also exhibited a good operational stability since 160 repeated measurements of 3 nmol of choline could be performed with an RSD of 4.5% whereas the stability under the best conditions was 45 assays with the other supports.
引用
收藏
页码:151 / 155
页数:5
相关论文
共 17 条
[1]  
Bardeletti G., 1991, BIOSENSOR PRINCIPLES, P7
[2]   ENHANCEMENT OF THE RESPONSE OF A LACTATE OXIDASE/PEROXIDASE-BASED FIBEROPTIC SENSOR BY COMPARTMENTALIZATION OF THE ENZYME LAYER [J].
BERGER, A ;
BLUM, LJ .
ENZYME AND MICROBIAL TECHNOLOGY, 1994, 16 (11) :979-984
[3]   CHEMILUMINESCENT FLOW-INJECTION ANALYSIS OF GLUCOSE IN DRINKS WITH A BIENZYME FIBEROPTIC BIOSENSOR [J].
BLUM, LJ .
ENZYME AND MICROBIAL TECHNOLOGY, 1993, 15 (05) :407-411
[4]  
BLUM LJ, 1997, BIO CHEMILUMINESCENT, P96
[5]   EVALUATION OF THE USE OF FREE AND IMMOBILIZED ACETYLCHOLINESTERASE FOR PARAOXON DETECTION WITH AN AMPEROMETRIC CHOLINE OXIDASE BASED BIOSENSOR [J].
CREMISINI, C ;
DISARIO, S ;
MELA, J ;
PILLOTON, R ;
PALLESCHI, G .
ANALYTICA CHIMICA ACTA, 1995, 311 (03) :273-280
[6]  
Engasser J.-M., 1976, APPLIED BIOCHEMISTRY, V1, P127
[7]   Flow injection determination of metrifonate by immobilised acetylcholinesterase inhibition [J].
Ghous, T ;
Townshend, A .
ANALYTICA CHIMICA ACTA, 1996, 332 (2-3) :179-185
[8]   CHARACTERIZATION OF INHIBITORS OF ACETYLCHOLINESTERASE BY AN AUTOMATED AMPEROMETRIC FLOW-INJECTION SYSTEM [J].
GUNTHER, A ;
BILITEWSKI, U .
ANALYTICA CHIMICA ACTA, 1995, 300 (1-3) :117-125
[9]  
Lapp H, 1996, ANAL LETT, V29, P1
[10]   Direct biosensor coating with a photopolymerised microlayer through a controllable step-procedure [J].
Leca, B ;
Morelis, RM ;
Coulet, PR .
MIKROCHIMICA ACTA, 1995, 121 (1-4) :147-154