Detector concept for OPET - A combined PET and optical Imaging system

被引:42
作者
Prout, DL [1 ]
Silverman, RW [1 ]
Chatziioannou, A [1 ]
机构
[1] Univ Calif Los Angeles, Geffen Sch Med, Crump Inst Mol Imaging, Los Angeles, CA 90095 USA
关键词
bioluminescence; microPET; positron emission tomography (PET); small animal imaging;
D O I
10.1109/TNS.2004.829736
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The design of an imaging system capable of detecting both high-energy gamma-rays and optical wavelength photons is underway at the UCLA Crump Institute for Molecular Imaging. This system, which we call optical PET (OPET), will be capable of noninvasively and repeatedly imaging small animal models in vivo for the presence of PET and optical signals. In this study, we describe the physical principles behind the operation of the OPET imaging system and discuss the design concept for one of the detector modules. Additionally, we demonstrate the operation of an initial prototype detector module for simultaneous detection and imaging of annihilation radiation and single optical photons emanating from separate sources. These results indicate that the construction of an imaging system based on this detector technology is feasible.
引用
收藏
页码:752 / 756
页数:5
相关论文
共 14 条
[1]  
Berger F, 2003, J NUCL MED, V44, p317P
[2]   A MULTICRYSTAL 2-DIMENSIONAL BGO DETECTOR SYSTEM FOR POSITRON EMISSION TOMOGRAPHY [J].
CASEY, ME ;
NUTT, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :460-463
[3]   Detector development for microPET II:: a 1 μl resolution PET scanner for small animal imaging [J].
Chatziioannou, A ;
Tai, YC ;
Doshi, N ;
Cherry, SR .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (11) :2899-2910
[4]  
Chatziioannou AF, 1999, J NUCL MED, V40, P1164
[5]   A REVIEW OF THE OPTICAL-PROPERTIES OF BIOLOGICAL TISSUES [J].
CHEONG, WF ;
PRAHL, SA ;
WELCH, AJ .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 1990, 26 (12) :2166-2185
[6]   COLLECTION OF SCINTILLATION LIGHT FROM SMALL BGO CRYSTALS [J].
CHERRY, SR ;
SHAO, YP ;
TORNAI, MP ;
SIEGEL, S ;
RICCI, AR ;
PHELPS, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :1058-1063
[7]   Use of reporter genes for optical measurements of neoplastic disease in vivo [J].
Contag, CH ;
Jenkins, D ;
Contag, FR ;
Negrin, RS .
NEOPLASIA, 2000, 2 (1-2) :41-52
[8]  
MARRIOTT CJ, 1994, J NUCL MED, V35, P1390
[9]   CERIUM-DOPED LUTETIUM OXYORTHOSILICATE - A FAST, EFFICIENT NEW SCINTILLATOR [J].
MELCHER, CL ;
SCHWEITZER, JS .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :502-505
[10]   Performance characteristics of micro crystal element (MiCE) detectors [J].
Miyaoka, RS ;
Kohlmyer, SG ;
Lewellen, TK .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) :1403-1407