Free-living energy expenditure in children using multi-sensor activity monitors

被引:52
作者
Arvidsson, Daniel [1 ]
Slinde, Frode [1 ]
Hulthen, Lena [1 ]
机构
[1] Univ Gothenburg, Dept Clin Nutr, Sahlgrenska Acad, SE-40530 Gothenburg, Sweden
关键词
Doubly labelled water; Indirect calorimetry; Physical activity; Validity; Reliability; PHYSICAL-ACTIVITY; HEART-RATE; VALIDATION; VALIDITY; ACCELEROMETER; ARMBAND; CALIBRATION; WALKING; SYSTEM; DEVICE;
D O I
10.1016/j.clnu.2009.03.006
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Aims: To improve the energy expenditure algorithm of the activity monitor ActiReg, and to validate ActiReg and the activity monitor SenseWear in free-living children. Methods: The development of the ActiReg algorithm was performed in 20 healthy 11-13 years old children on treadmill walking and running with indirect calorimetry as reference. The original and new ActiReg algorithms and SenseWear using software versions InnerView 5.1 and 6.1 were validated in 20 healthy 14-15 years old children against doubly labelled water. Results: The new ActiReg algorithm improved the assessment of energy expenditure during walking and running, but the response from the monitor levelled off after 7 km h(-1). The new algorithm and InnerView 6.1 decreased the mean (sd) difference to doubly labelled water from 11 (25) (P < 0.05) to 0 (22) kJ kg(-1) d(-1) for ActiReg, and from 17 (20) (P < 0.01) to -10 (21) (P < 0.05) kJ kg(-1) d(-1) for SenseWear. However, the correlations between energy expenditure and the individual error for the new ActiReg algorithm and InnerView 6.1 were r = -0.50 (P < 0.05) and r = -0.73 (P < 0.01). Conclusions: The new ActiReg algorithm and InnerView 6.1 improved the activity monitors at group level, but the error was dependent on physical activity level. Both activity monitors need further developments for use in children. (C) 2009 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
引用
收藏
页码:305 / 312
页数:8
相关论文
共 36 条
[1]  
[Anonymous], HUM EN REQ
[2]   Validity of the ActiReg system in assessing energy requirement in chronic obstructive pulmonary disease patients [J].
Arvidsson, D ;
Slinde, F ;
Nordenson, A ;
Larsson, S ;
Hulthén, L .
CLINICAL NUTRITION, 2006, 25 (01) :68-74
[3]   Energy cost of physica activities in Children:: Validation of sensewear armband [J].
Arvidsson, Daniel ;
Slinde, Frode ;
Larsson, Sven ;
Hulthen, Lena .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2007, 39 (11) :2076-2084
[4]   Energy Cost in Children Assessed by Multisensor Activity Monitors [J].
Arvidsson, Daniel ;
Slinde, Frode ;
Larsson, Sven ;
Hulthen, Lena .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2009, 41 (03) :603-611
[5]   Reexamination of validity and reliability of the CSA monitor in walking and running [J].
Brage, S ;
Wedderkopp, N ;
Franks, PW ;
Andersen, LB ;
Froberg, K .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (08) :1447-1454
[6]   Branched equation modeling of simultaneous accelerometry and heart rate monitoring improves estimate of directly measured physical activity energy expenditure [J].
Brage, S ;
Brage, N ;
Franks, PW ;
Ekelund, U ;
Wong, MY ;
Andersen, LB ;
Froberg, K ;
Wareham, NJ .
JOURNAL OF APPLIED PHYSIOLOGY, 2004, 96 (01) :343-351
[7]   Assessing energy expenditure in cancer patients: A pilot validation of a new wearable device [J].
Cereda, Emanuele ;
Turrini, Mauro ;
Ciapanna, Denis ;
Marbello, Laura ;
Pietrobelli, Angelo ;
Corradi, Ettore .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2007, 31 (06) :502-507
[8]   The technology of accelerometry-based activity monitors: Current and future [J].
Chen, KY ;
Bassett, DR .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 (11) :S490-S500
[9]   Calibration of the RT3 accelerometer for ambulation and nonambulation in children [J].
Chu, Eva Y. W. ;
McManus, Alison M. ;
Yu, Clare C. W. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2007, 39 (11) :2085-2091
[10]  
Cole PJ, 2004, J SPORT MED PHYS FIT, V44, P262