Experiments with CHRELMS patient-driven stimulator controllers for the restoration of function to paralysed legs

被引:10
作者
Donaldson, N [1 ]
Yu, CH [1 ]
机构
[1] UCL, Dept Med Phys & Bioengn, London WC1E 6JA, England
关键词
functional electrical stimulation; neuroprosthetics; paraplegia; patient-driven control; CHRELMS;
D O I
10.1243/0954411001535200
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper examines the control of electrical stimulators for restoring the standing function to paraplegics. Patient-driven controllers are based on the knowledge that standing, using support handles, is guided by the neurologically intact natural motor control system, acting through the arms. One category of patient-driven controller is CHRELMS (Control by Handle Reactions of Leg Muscle Stimulation). The first experiments with patient-driven controllers are reported. Experiments in the CHRELMS control of one volunteer are described. Proportional control did not allow the subject to stand up because of the strategy he used, but integral control was successful. With it, he could stand up and sit down slowly, entirely guided by himself, as well as making other manoeuvres. Without changing controller mode, and by leaning forwards and backwards, he could 'posture switch' his support muscles. These are significant achievements and justify a larger study of patient-driven controllers. The subject's control strategies are discussed.
引用
收藏
页码:1 / 20
页数:20
相关论文
共 33 条
[1]   HYBRID FES ORTHOSIS INCORPORATING CLOSED-LOOP CONTROL AND SENSORY FEEDBACK [J].
ANDREWS, BJ ;
BAXENDALE, RH ;
BARNETT, R ;
PHILLIPS, GF ;
YAMAZAKI, T ;
PAUL, JP ;
FREEMAN, PA .
JOURNAL OF BIOMEDICAL ENGINEERING, 1988, 10 (02) :189-195
[2]  
ANDREWS BJ, 1998, P 6 VIENN INT WORKSH, P271
[3]  
ASTROM KJ, 1990, COMPUTER CONTROLLED, P225
[4]   THE FIRST 500 PATIENTS WITH SACRAL ANTERIOR ROOT STIMULATOR IMPLANTS - GENERAL DESCRIPTION [J].
BRINDLEY, GS .
PARAPLEGIA, 1994, 32 (12) :795-805
[5]   The effects of common peroneal stimulation on the effort and speed of walking: a randomized controlled trial with chronic hemiplegic patients [J].
Burridge, JH ;
Taylor, PN ;
Hagan, SA ;
Wood, DE ;
Swain, ID .
CLINICAL REHABILITATION, 1997, 11 (03) :201-210
[6]  
Davoodi R, 1998, IEEE Trans Rehabil Eng, V6, P151, DOI 10.1109/86.681180
[7]  
Donaldson N, 1998, IEEE Trans Rehabil Eng, V6, P162, DOI 10.1109/86.681181
[8]  
Donaldson N de N, 1996, IEEE Trans Rehabil Eng, V4, P280, DOI 10.1109/86.547928
[9]  
DONALDSON NN, 1996, P 9 INT C MECH MED B, P425
[10]   PRACTICAL LOW-COST STAND SIT SYSTEM FOR MID-THORACIC PARAPLEGICS [J].
EWINS, DJ ;
TAYLOR, PN ;
CROOK, SE ;
LIPCZYNSKI, RT ;
SWAIN, ID .
JOURNAL OF BIOMEDICAL ENGINEERING, 1988, 10 (02) :184-188