Accuracy of normal-dose contrast-enhanced MR angiography in assessing renal artery stenosis and accessory renal arteries

被引:50
作者
Korst, MBJM
Joosten, FBM
Postma, CT
Jager, GJ
Krabbe, JK
Barentsz, JO
机构
[1] Univ Nijmegen Hosp, Dept Radiol, NL-6500 HB Nijmegen, Netherlands
[2] Univ Nijmegen Hosp, Dept Internal Med, NL-6500 HB Nijmegen, Netherlands
关键词
D O I
10.2214/ajr.174.3.1740629
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to evaluate the accuracy of breath-hold contrast-enhanced MR angiography in the assessment of renal artery stenosis and accessory renal arteries using a standard dose of gadolinium. SUBJECTS AND METHODS. Thirty-eight patients suspected of having renal artery stenosis underwent MR angiography and intraarterial digital subtraction angiography, which was the method of reference. Three-dimensional gradient-echo MR subtraction angiography (TRITE, 5.8/1.8 msec) was performed on a 1.5-T imager using a phased array body coil. Be fore imaging, a separate timing bolus sequence was used, administering 1.0 ml of contrast agent. Gadopentetate dimeglumine (15 ml) was injected using an MR power injector. Two observers, who were unaware of each other's interpretation and of MR findings, assessed digital subtraction angiography. Likewise, two other observers assessed MR angiography. RESULTS. Digital subtraction angiography depicted 75 main and 17 accessory renal arteries (n = 92). All main renal arteries and 13 accessory renal arteries were identified on MR angiography. Compared with digital subtraction angiography, MR imaging correctly classified 57 of 66 arteries without a hemodynamically significant stenosis (0-49%), 22 of 22 arteries as significantly stenotic (50-99%), and four of four occluded arteries; five stenoses were overestimated. There was one false-positive finding of an accessory renal artery on MR angiography that was identified retrospectively on digital subtraction angiography. Interobserver agreement was high. Sensitivity and specificity for grading significant stenosis were 100% and 85%, respectively. CONCLUSION, Contrast-enhanced MR angiography, using +/-0.1 mmol/kg of gadolinium, is an accurate method in the assessment of renal artery stenosis and accessory renal arteries.
引用
收藏
页码:629 / 634
页数:6
相关论文
共 35 条
[21]   CLINICAL SAFETY OF GADOPENTETATE DIMEGLUMINE [J].
NELSON, KL ;
GIFFORD, LM ;
LAUBERHUBER, C ;
GROSS, CA ;
LASSER, TA .
RADIOLOGY, 1995, 196 (02) :439-443
[22]  
Porush JG, 1996, ARCH INTERN MED, V156, P1938
[23]   Magnetic resonance angiography has a high reliability in the detection of renal artery stenosis [J].
Postma, CT ;
Joosten, FBM ;
Rosenbusch, G ;
Thien, T .
AMERICAN JOURNAL OF HYPERTENSION, 1997, 10 (09) :957-963
[24]  
Prince M R, 1998, Magn Reson Imaging Clin N Am, V6, P257
[25]   BREATH-HOLD GADOLINIUM-ENHANCED MR-ANGIOGRAPHY OF THE ABDOMINAL-AORTA AND ITS MAJOR BRANCHES [J].
PRINCE, MR ;
NARASIMHAM, DL ;
STANLEY, JC ;
CHENEVERT, TL ;
WILLIAMS, DM ;
MARX, V ;
CHO, KJ .
RADIOLOGY, 1995, 197 (03) :785-792
[26]   Renal MR angiography: A comprehensive approach [J].
Prince, MR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03) :511-516
[27]   GADOLINIUM-ENHANCED MR AORTOGRAPHY [J].
PRINCE, MR .
RADIOLOGY, 1994, 191 (01) :155-164
[28]   Contrast-enhanced abdominal MR angiography: Optimization of imaging delay time by automating the detection of contrast material arrival in the aorta [J].
Prince, MR ;
Chenevert, TL ;
Foo, TKF ;
Londy, FJ ;
Ward, JS ;
Maki, JH .
RADIOLOGY, 1997, 203 (01) :109-114
[29]  
Schoenberg S O, 1998, Magn Reson Imaging Clin N Am, V6, P351
[30]   MULTICOIL HIGH-RESOLUTION FAST SPIN-ECHO MR IMAGING OF THE FEMALE PELVIS [J].
SMITH, RC ;
REINHOLD, C ;
MCCAULEY, TR ;
LANGE, RC ;
CONSTABLE, RT ;
KIER, R ;
MCCARTHY, S .
RADIOLOGY, 1992, 184 (03) :671-675